Shows / Gritty Sprinkler Fitter

Gritty Sprinkler Fitter
Two Minnesota sprinkler fitters: FIELD, a beat-up old journeyman who's hung more pipe than you've walked past, and CODE, a cocky apprentice who's read the book twice and thinks that makes him dangerous. Raw, 18+ late-night talk on the MN Journeyman Sprinkler Fitter exam, built on the MSFC, NFPA 13, 14 and 25 and Minnesota rules, checked against the text, not barstool lore. Made by fitters who still work the job, for the brothers and sisters trying to get that card. Pair it with the MN…
The show, from its episodes
No episode notes yet. Recurring topics, people and starter picks will appear when notes are available.
Typical episode length
22m · median of 193 episodes with a known length
Solo / guest format
Unknown — existing notes name people mentioned, but do not identify hosts or guests.
Recurring topics
No recurring topics established yet.
Recurring people
No recurring people established yet.
Start here
No starter picks yet — no published episodes with audio and a recorded notes hook.
Episodes
Gritty Sprinkler FitterQuizlet Part 2
This text is a compilation of questions and answers regarding fire sprinkler system installation and maintenance, drawing heavily from various NFPA standards…
Gritty Sprinkler FitterQuizlet Part 1
This text comprises a series of questions and answers relating to fire sprinkler system installation and maintenance, drawing heavily from various editions of…
Gritty Sprinkler FitterMN Exam
The provided texts are excerpts from various NFPA (National Fire Protection Association) standards and training materials related to fire protection systems…
Gritty Sprinkler FitterFire Sprinkler Systems 101 Application of NFPA 13, NFPA 14 & Florida Building Code
The sources provide an educational overview of fire sprinkler and standpipe systems, covering both historical context and contemporary standards. The video…
Gritty Sprinkler FitterHome Fire Sprinkler Water Supply Guide (Complete)
The "Home Fire Sprinkler Coalition" YouTube video explains the benefits of residential fire sprinkler systems. It covers their effectiveness in preventing…
Gritty Sprinkler FitterQ & A Session on Inspection, Testing and Maintenance and NFPA 25
This is a Q&A session on NFPA 25, the standard for the inspection, testing, and maintenance (ITM) of fire sprinkler systems. The speaker discusses the…
Gritty Sprinkler FitterFire Sprinkler Training
The source is a transcript of a video that discusses the workings of a fire sprinkler system in a multi-story building. The speaker, a fire protection…
Gritty Sprinkler FitterConverting Hydrant Flow Test Results to GPM
The source is a video transcript from the YouTube channel "16FLSI" and it explains how to calculate gallons per minute (GPM) of water flow from a fire hydrant…
Gritty Sprinkler FitterSprinklermatic University - Introduction to Automatic Sprinkler Systems
This is an excerpt from a lecture presented by Sprinklermatic University on the basics of automatic sprinkler systems. The presentation begins with an overview…
Gritty Sprinkler FitterFire Sprinkler Systems Explained
Fire sprinkler systems have proven to be remarkably effective in combating fires, saving lives and property for over 120 years. These systems, which are…
Gritty Sprinkler FitterSprinkler Installation Requirements in NFPA 13
This is a training seminar transcript from the YouTube channel Sprinklermatic. The video focuses on sprinkler installation requirements in NFPA 13, a fire…
Gritty Sprinkler FitterClass 26 | How to design sprinkler system? NFPA 13
This excerpt from a YouTube video by Irfan CFPS, a certified fire protection specialist, provides a step-by-step guide on how to design a wet sprinkler system…
Gritty Sprinkler FitterClass 25 | Flow from sprinklers : Water Demand Calculation
This excerpt from a YouTube video on sprinkler system design outlines the steps involved in calculating the theoretical water demand for a sprinkler system…
Gritty Sprinkler FitterClass 24 | Firefighting Installation Details
This is a YouTube video tutorial by Irfan CFPS that covers the installation details of various components of a fire fighting system. The video uses images to…
Gritty Sprinkler FitterClass 22 | In Rack Sprinkler System
This YouTube video by Irfan CFPS demonstrates how to calculate the water demand for in-rack sprinkler systems in warehouses, which are designed to protect…
Gritty Sprinkler FitterClass 21 | ESFR Sprinklers for Storage Applications | NFPA 13
This YouTube video provides a tutorial on how to calculate water demand requirements for storage warehouses using ESFR sprinklers. The speaker uses a…
Gritty Sprinkler FitterClass 20 | CMSA Sprinklers for Storage Applications | NFPA 13
This YouTube video provides a detailed explanation of how to calculate the water demand for a storage warehouse sprinkler system using the CMSA approach, a…
Gritty Sprinkler FitterClass 19 | CMDA Sprinklers for Storage Applications
This YouTube video from "Irfan CFPS" explains the concept of CMDA sprinklers, which are a type of sprinkler designed for fire control in storage applications…
Gritty Sprinkler FitterClass 18 | Friction Loss Calculation | Hazen Williams Formula | Hydraulic Calculations
This YouTube video, "Class 18 | Friction Loss Calculation | Hazen Williams Formula | Hydraulic Calculations," by "Irfan CFPS" provides a tutorial on…
Gritty Sprinkler FitterClass 17 | Fire Sprinklers Design Layout as per NFPA 13
This YouTube video from the channel "Irfan CFPS" provides a step-by-step guide on designing an automatic sprinkler system for an office using NFPA 13…
Gritty Sprinkler FitterClass 16 | Hydraulic Calculations for Sprinkler Systems
This YouTube video tutorial, titled "Class 16 | Hydraulic Calculations for Sprinkler Systems," focuses on understanding hydraulic calculations for sprinkler…
Gritty Sprinkler FitterClass 15 | Pipe schedule Method For Sprinkler System
The video "Class 15 | Pipe schedule Method For Sprinkler System" uploaded by "Irfan CFPS" on YouTube explains the "pipe schedule method," a traditional…
Gritty Sprinkler FitterClass 14 | Pipe Hangers and Supports | Sprinkler System Piping as per NFPA13
This transcript from a YouTube video discusses the design and installation of sprinkler system piping supports, specifically addressing the requirements…
Gritty Sprinkler FitterClass 13 | "How To Classify Commodities For NFPA 13 Compliance"
The YouTube video "Class 13 | "How To Classify Commodities For Nfpa 13 Compliance"" by "Irfan CFPS" explains how to classify commodities based on their fire…
Gritty Sprinkler FitterClass 12 | Classification of Hazard Occupancies as per NFPA13
This source is a video lesson from a YouTube channel called "Irfan CFPS" that explains the different occupancy hazard classifications used in NFPA 13, the…
Gritty Sprinkler FitterClass 11 | Sprinkler System Components as per NFPA13
This excerpt from a YouTube video by Irfan CFPS, a certified fire protection specialist, focuses on the components of sprinkler systems as outlined by NFPA 13…
Gritty Sprinkler FitterClass 10 | Types of Sprinklers
This excerpt from a YouTube video provides a comprehensive overview of sprinklers used in fire protection systems, as outlined in NFPA 13 standards. It details…
Gritty Sprinkler FitterClass 9 | Deluge Sprinkler Systems
The video, "Class 9 | Deluge Sprinkler Systems," provides an introduction to Deluge sprinkler systems as part of a larger training series on NFPA 13, which…
Gritty Sprinkler FitterClass 8 | Double Interlock Preaction System | Part 3
The video transcript explains the operation of a double interlock preaction system, a type of fire suppression system commonly used in refrigerated areas. This…
Gritty Sprinkler FitterClass 7 | Non Interlock Preaction System | Part 2
This YouTube video tutorial focuses on non-interlock preaction systems used in fire suppression. It explores two types: electric release and pneumatic release…
Gritty Sprinkler FitterClass 6 | Single Interlock Preaction System | Types of Preaction systems | Part 1
This video from the "Irfan CFPS" YouTube channel provides a detailed explanation of single interlock preaction systems, a type of fire sprinkler system. The…
Gritty Sprinkler FitterClass 5 | Pre Action Sprinkler System
This YouTube video, titled "Class 5 | Pre action sprinkler system," is part of a series that explains different types of sprinkler systems. The video focuses…
Gritty Sprinkler FitterClass 4 | Dry Pipe Sprinkler System
This transcript from a YouTube video by Irfan CFPS provides an overview of dry pipe sprinkler systems. Dry pipe systems are a type of automatic fire sprinkler…
Gritty Sprinkler FitterClass 3 | Wet Pipe Sprinkler Systems
The YouTube video "Class 3 | Wet pipe sprinkler systems" by Irfan CFPS explains the operation of wet pipe sprinkler systems, the most common type of automatic…
Gritty Sprinkler FitterClass 2 | Hydrant Flow Test Procedure | Types of Water Supplies | NFPA 291 | NFPA 13
This excerpt from a YouTube video discusses the importance of water supplies in fire protection systems, specifically those regulated by the NFPA 13 standard…
Gritty Sprinkler FitterClass 1 | Introduction to NFPA 13 | Standard for the Installation of Sprinkler Systems
This YouTube video from the "Irfan CFPS" channel provides an introduction to NFPA 13, a standard governing the installation of sprinkler systems. The video…
Gritty Sprinkler FitterNFPA 20 - Fire Pumps
Summary NFPA 20 is a standard for the installation of stationary pumps for fire protection, covering everything from water source requirements and pump types…
Gritty Sprinkler FitterNFPA 13 - Small Room Rule
Summary of the Small Room Rule The Small Room Rule, as defined in Section 3.3.22 of the NFPA 13 – Sprinkler Systems (2016 edition), applies to compartments…
Gritty Sprinkler FitterDifference between Quick and Standard Response Fire Sprinklers
Summary This YouTube video from "NFPA Joe" explains the difference between standard response and quick response fire sprinkler heads. The video explains that…
Gritty Sprinkler FitterNFPA 13 & NFPA 70 - Fire Sprinklers in Electrical Rooms
Summary The YouTube video discusses how fire sprinkler systems are installed in electrical rooms, adhering to the guidelines outlined in NFPA 13 and NFPA 70…
Gritty Sprinkler FitterNFPA 13 Light Hazard Occupancy Fire Sprinkler Head Spacing
Summary The video from the YouTube channel "NFPA Joe" explains the concept of light hazard occupancy as defined by the National Fire Protection Association…
Gritty Sprinkler FitterNFPA 13 Obstructed & Unobstructed Construction, and Fire Sprinkler distance below ceiling
Summary NFPA 13, a standard for the installation of sprinkler systems, defines unobstructed construction as a building structure that does not hinder the flow…
Gritty Sprinkler FitterNFPA 13 Soffit and Cabinet Rule
Summary The NFPA 13 Soffit and Cabinet Rule, as explained by NFPA Joe on YouTube, dictates the placement of sprinkler heads in relation to obstructions like…
Gritty Sprinkler FitterNFPA 13 3x & 4x Rule
Summary The YouTube video from "NFPA Joe" explains the three and four times rule, which is used in NFPA 13 to determine the proper placement of sprinkler heads…
Gritty Sprinkler FitterMN Statutes 299M Licensing Rules - Audio Overview
Summary The document, MN Statutes 299M Licensing Rules.pdf, outlines the licensing and certification requirements for individuals and companies working in the…
Gritty Sprinkler FitterMinnesota Fire Code Sprinkler Requirements: A Detailed Breakdown - Adopted Fire Protection Standards
II. Adopted Fire Protection Standards List of NFPA standards adopted by reference, including the relevant edition year for each.
Gritty Sprinkler FitterMinnesota Fire Code Sprinkler Requirements: A Detailed Breakdown - Introduction
Minnesota Fire Code Sprinkler Requirements: A Detailed Breakdown Source: Memorandum from Jon Nisja, Fire Safety Supervisor, Minnesota Department of Public…
Gritty Sprinkler FitterMN Adopted Codes & Changes FAQ: What are the requirements for fire department connections (FDCs) in Minnesota?
What are the requirements for fire department connections (FDCs) in Minnesota? A check valve is required within 25 feet of the fire department connection (FDC)…
Gritty Sprinkler FitterMN Adopted Codes & Changes FAQ: Are there any exemptions to the sprinkler requirements in Minnesota?
Yes, certain areas or spaces may be exempt from sprinkler protection. Some examples include: Elevator shafts and equipment rooms: Except in healthcare…
Gritty Sprinkler FitterMN Adopted Codes & Changes FAQ: Are sprinkler systems required in all new construction projects in Minnesota?
No, not all new construction projects require sprinkler systems. Sprinkler requirements vary depending on the occupancy type and size of the building. For…
Gritty Sprinkler FitterMN Adopted Codes & Changes FAQ: What are the current editions of the fire protection standards adopted by the Minnesota State Fire Code (MSFC)?
The MSFC adopts the following fire protection standards by reference: NFPA 10 – Portable Fire Extinguishers (2017 edition) NFPA 13 – Sprinkler Systems (2016…
Gritty Sprinkler Fitter2020 MN Fire Code: Where are standpipe hose connections required in a building?
Standpipe hose connections are required in various locations within a building, including: Within the mall at the entrance to each exit passageway or corridor…
Gritty Sprinkler Fitter2020 MN Fire Code: What are the requirements for fire extinguishing systems protecting cooking equipment?
Cooktops and ranges in certain occupancies (Group I-1 and I-2, Condition 1) must be protected by fire extinguishing systems that meet the following…
Gritty Sprinkler Fitter2020 MN Fire Code: What are the testing requirements for fire extinguishing system hoses?
Hoses should be examined for damage every 12 months. Damaged hoses should be replaced or tested. All hoses shall be tested every five years. The test pressure…
Gritty Sprinkler Fitter2020 MN Fire Code: How often should high-pressure cylinders in fire extinguishing systems be inspected?
High-pressure cylinders should be weighed and the date of the last hydrostatic test verified every six months. If a container shows a content loss of more than…
Gritty Sprinkler Fitter2020 MN Fire Code FAQ: What are the supervision and alarm requirements for sprinkler systems?
Valves controlling the water supply, pumps, tanks, water levels and temperatures, critical air pressures, and waterflow switches on all sprinkler systems shall…
Gritty Sprinkler Fitter2020 MN Fire Code FAQ: What are the requirements for automatic sprinkler systems?
When the domestic service provides the water supply for the automatic sprinkler system, the supply shall be in accordance with Section 903.3.5.1 of the…
Gritty Sprinkler Fitter2020 MN Fire Code FAQ: Are sprinklers required in bathrooms?
In Group R occupancies, sprinklers are not required in bathrooms that meet all of the following conditions: Do not exceed 55 square feet in area. Located…
Gritty Sprinkler Fitter2020 MN Fire Code FAQ: Where are automatic sprinkler systems required during construction?
Automatic sprinkler systems are required during construction, alteration, and demolition operations in accordance with Section 3314 of the Minnesota State Fire…
Gritty Sprinkler FitterNFPA 13 - General Information. Chapters 1, 2, and 3.
Chapters 1, 2, and 3 of NFPA 13 These chapters provide the administrative and definitional framework for the rest of NFPA 13. They establish the purpose and…