Shows / Gritty Sprinkler Fitter

Gritty Sprinkler Fitter
Two Minnesota sprinkler fitters: FIELD, a beat-up old journeyman who's hung more pipe than you've walked past, and CODE, a cocky apprentice who's read the book twice and thinks that makes him dangerous. Raw, 18+ late-night talk on the MN Journeyman Sprinkler Fitter exam, built on the MSFC, NFPA 13, 14 and 25 and Minnesota rules, checked against the text, not barstool lore. Made by fitters who still work the job, for the brothers and sisters trying to get that card. Pair it with the MN…
The show, from its episodes
No episode notes yet. Recurring topics, people and starter picks will appear when notes are available.
Typical episode length
22m · median of 193 episodes with a known length
Solo / guest format
Unknown — existing notes name people mentioned, but do not identify hosts or guests.
Recurring topics
No recurring topics established yet.
Recurring people
No recurring people established yet.
Start here
No starter picks yet — no published episodes with audio and a recorded notes hook.
Episodes
Gritty Sprinkler FitterNFPA 13 Control Valves: Listed Indicating Valves, PIVs, Check Valves & Supervision | MN Journeyman Exam Prep
Control valves: listed indicating valves, PIVs and wall PIVs, check valves, and the four ways to supervise a valve. We cover valve location and accessibility…
Gritty Sprinkler FitterHydraulics for the MN Exam: Hazen-Williams, C-Factors, Friction Loss & Equivalent Length | MN Journeyman Exam Prep
The Hazen-Williams formula in plain English, the C-factor table (100, 120, 140, 150), why the fitting table is "C = 120 only" and how the multipliers work…
Gritty Sprinkler FitterNFPA 13 High-Piled Storage & Commodity Classification: Classes, Arrays & Ceiling Sprinklers | MN Journeyman Exam Prep
Class I through IV, Group A/B/C plastics, cartoned vs. exposed, the 5/15 and 5/25/40 percentage rules, plastic pallets, open vs. closed arrays, rack types…
Gritty Sprinkler FitterNFPA 13 Water Supplies: Duration, Hose Stream Allowances & Pressure Requirements | MN Journeyman Exam Prep
Is there enough water, for long enough? At least one automatic supply, what counts as a supply, the 6-inch private main rule, pressure tanks, a live…
Gritty Sprinkler FitterNFPA 13 Wet Pipe Systems: Alarm Check Valves, Retard Chambers & Waterflow Alarms | MN Journeyman Exam Prep
The plain-Jane system nobody studies. How an alarm check valve and retard chamber actually work (and why a plugged retard drain makes the outside bell ring…
Gritty Sprinkler FitterNFPA 13 Obstructions to Spray Patterns: Continuous, Noncontinuous & Shadow Areas | MN Journeyman Exam Prep
Eighteen inches below the deflector splits the whole chapter. Above it, the spray pattern's still developing: the three times rule (24-inch cap, but not for…
Gritty Sprinkler FitterNFPA 13 Hangers & Supports: Spacing, Rod Sizes & Fasteners (Non-Seismic) | MN Journeyman Exam Prep
Holding the pipe up, no sway bracing. Five times water-filled plus 250 lb vs. what the building has to carry, listed vs. unlisted parts, rod and U-hook sizes…
Gritty Sprinkler FitterNFPA 13 Sprinkler Spacing & Protection Area: Light, Ordinary & Extra Hazard | MN Journeyman Exam Prep
How far apart, how far off the wall, and how much floor one standard spray head is allowed to cover. We walk the S x L method, the light/ordinary/extra hazard…
Gritty Sprinkler FitterNFPA 2001 Clean Agents & MSFC 904.10: Design Concentration, Discharge Time, Hold Time & Inspections | MN Journeyman Exam Prep
Clean agent systems: NFPA 2001 and Minnesota 904.10. Halocarbons vs. inert gases, safety factors, the 10-second discharge, the 85%/10-minute hold, abort vs…
Gritty Sprinkler FitterNFPA 72 & MSFC 903.4 Sprinkler Supervision: Waterflow, Tamper, Supervisory Signals & Exterior Alarms | MN Journeyman Exam Prep
The alarm side of sprinklers: NFPA 72 and Minnesota 903.4. Waterflow in 90 seconds, tamper switches in two turns, supervisory pressure, level and temperature…
Gritty Sprinkler FitterNFPA 20 Fire Pumps & MSFC 913: Suction, Relief Valves, Pump Rooms & Acceptance Tests | MN Journeyman Exam Prep
Fire pumps, NFPA 20 and Minnesota 913. Suction rules that keep pumps alive (zero psi at 150%, OS&Y only within 50 feet, ten pipe diameters, eccentric…
Gritty Sprinkler FitterNFPA 14 Standpipes & MSFC 905: Classes, Pressures, Flows & Minnesota Hose Connections | MN Journeyman Exam Prep
Standpipes, NFPA 14 and Minnesota 905. Classes I, II and III, wet vs. dry vs. manual vs. semiautomatic, pressure limits and PRVs, flow rates, and Minnesota's…
Gritty Sprinkler FitterNFPA 10 Portable Fire Extinguishers: Ratings, Placement, Inspection & Hydro | MN Journeyman Exam Prep
Halloween special: portable fire extinguishers. Ratings, placement and travel distance, monthly inspections, annual maintenance, and hydro intervals under NFPA…
Gritty Sprinkler FitterNFPA 24 Underground Mains: Bury Depth, Thrust Restraint, Flushing & Hydro | MN Journeyman Exam Prep
Underground private fire service mains: bury depth, thrust blocks and restraint, flushing flows, and the hydro test. Everything that goes in the dirt before…
Gritty Sprinkler FitterNFPA 22 Water Tanks: Heating, Suction Tanks, Vortex Plates & Levels | MN Journeyman Exam Prep
Water tanks for fire protection, the NFPA 22 way. We dig into tank heating and the 40-degree rule, suction tanks, vortex plates, and the level and temperature…
Gritty Sprinkler FitterSeismic Protection: Flex Couplings, Clearance, Sway Bracing & Restraint | MN Journeyman Exam Prep
Seismic protection for sprinkler piping, for the Minnesota journeyman sprinkler fitter exam. Minnesota pins NFPA 13-2016, where this is section 9.3. NFPA…
Gritty Sprinkler FitterNFPA 13R Low-Rise Residential | MN Journeyman Exam Prep
NFPA 13R, sprinklers for low-rise residential buildings (apartments, hotels, dorms, board and care), for the Minnesota journeyman sprinkler fitter exam. Every…
Gritty Sprinkler FitterNFPA 13D One- & Two-Family Dwellings | MN Journeyman Exam Prep
NFPA 13D, sprinklers for one- and two-family dwellings and manufactured homes, for the Minnesota journeyman sprinkler fitter exam. Minnesota pins 13D-2016…
Gritty Sprinkler FitterSprinkler Identification, Temperature Ratings & Spare Sprinklers | MN Journeyman Exam Prep
Sprinkler identification, temperature ratings and spare sprinklers for the Minnesota journeyman sprinkler fitter exam. NFPA 13 (2016 6.2/8.3, the edition…
Gritty Sprinkler FitterOccupancy Hazard Classification & Design Density | MN Journeyman Exam Prep
Occupancy hazard classification and what it does to your design, for the Minnesota journeyman sprinkler fitter exam. NFPA 13 (2016 ch.5/11, the edition…
Gritty Sprinkler FitterPipe, Fittings & Joining Methods | MN Journeyman Exam Prep
Pipe, fittings and joining methods, every rule a Minnesota journeyman sprinkler fitter needs for the exam. NFPA 13 (2016 chapter 6, the edition Minnesota pins…
Gritty Sprinkler FitterAntifreeze Systems | MN Journeyman Exam Prep
Antifreeze sprinkler systems, every rule a Minnesota journeyman sprinkler fitter needs for the exam. NFPA 13 (2016 section 7.6, the edition Minnesota pins…
Gritty Sprinkler FitterDry Pipe & Preaction Systems | MN Journeyman Exam Prep
Dry pipe and preaction systems (plus a little deluge), every rule a Minnesota journeyman sprinkler fitter needs for the exam. NFPA 13 (2016, the edition…
Gritty Sprinkler FitterFire Department Connections | MN Journeyman Exam Prep
Fire department connections, every rule a Minnesota journeyman sprinkler fitter needs for the exam. Minnesota State Fire Code 2020 Section 912: location…
Gritty Sprinkler FitterKitchen Hoods & Alternative Extinguishing Systems | MN Journeyman Exam Prep
Minnesota State Fire Code 2020 Section 904, the systems that aren't sprinklers but land on a sprinkler fitter's plate anyway. Minnesota's amended 904.1.1…
Gritty Sprinkler FitterListener Prep Sheet: Deflectors, Obstructions, Sidewalls, Drains, Hangers & ITM | MN Journeyman Exam Prep
A listener handed us his LICENSING EXAM - PREP QUESTIONS study sheet, and we go through every line of it with the books open. NFPA 13 deflector position and…
Gritty Sprinkler FitterLimited Area Sprinklers, Quick Response & Water Supplies | MN Journeyman Exam Prep
The installation rules in Minnesota State Fire Code 2020 Section 903.3 that nobody reads until an inspector reads them to you. Where quick-response or…
Gritty Sprinkler FitterJoining the Sprinkler Fitter Union in Minnesota | MN Journeyman Exam Prep
How you actually get into the sprinkler fitter union in Minnesota, read off the sources, not off barstool rumors. Sprinkler Fitters Local 417 (chartered 1903)…
Gritty Sprinkler FitterApprentice Questions Answered | MN Journeyman Exam Prep
Every question Minnesota sprinkler apprentices ask, answered from Minn. Stat. 299M, Minn. R. 7512 and the State Fire Marshal's exam booklet: who qualifies for…
Gritty Sprinkler FitterTake a Number, Asshole — Who the AHJ Is in Minnesota, Permits, Surcharges and City Permit Programs
Who's actually the authority having jurisdiction for a sprinkler job in Minnesota, the city or the state, and what that means for your permit, your cost…
Gritty Sprinkler FitterPut the Fucking Tile Back — Minnesota's Ceiling Rules and Existing-Building Sprinkler Amendments
Minnesota added its own ceiling rules in 7511.0901 (IFC 901.11): ceiling tiles stay in place, open-grid ceilings don't go under sprinklers unless NFPA 13 is…
Gritty Sprinkler FitterBonus: Annual, 3-Year and 5-Year Inspections — What You Actually Fucking Do (NFPA 25 + Minnesota's Annual Rollup)
Two fitters walk through what actually gets inspected, tested and maintained on a sprinkler system every year, every 3 years and every 5 years under NFPA 25…
Gritty Sprinkler FitterMinnesota Fucked With Your Standard — 7511.8000 and the State's Amendments to NFPA 13, 13R, and 13D
Minnesota doesn't just adopt NFPA 13, 13R, and 13D. It pins the editions in Minn. R. 7511.8000 and rewrites pieces of them through the fire code: linen…
Gritty Sprinkler FitterBonus: Who the Fuck Shut the Valve? — Impairments, Tags, and Fire Watch When the System's Out of Service
When a sprinkler system goes out of service in Minnesota, the fire code doesn't give you a grace period. It says notify the fire department and the fire code…
Gritty Sprinkler FitterBonus: We Fucked Up — Red-Tagging Our Own Cheat Sheet Episode
Our Cheat Sheet bonus taught you some rules the 2025 NFPA 13 and 2026 NFPA 25 already changed, so we're red-tagging our own work on air. ESFR slope, the dead…
Gritty Sprinkler FitterBonus: Casey's Cheat Sheet — Fifteen Scribbled Study Notes, Fact-Checked Against the Actual Book
Casey fed a page of his own exam notes through the scanner, so we went line by line against NFPA 13, 13R, 13D, NFPA 25, the JATC math book, and Minnesota's…
Gritty Sprinkler FitterWhere Minnesota Says Sprinkle It — 7511.0903 Triggers, Thresholds, and the 5 PSI Tax
Minnesota rewrote big chunks of IFC Section 903, including Group E, Group R, S-1 storage, exhaust ducts, undetermined-use buildings, and a 5 psi water supply…
Gritty Sprinkler FitterInspect My Ass — Who's Legally Allowed to Touch a Minnesota Sprinkler System
A deep dive into the scope and exceptions of Minn. R. 7512 and Minn. Stat. 299M — what "fire protection-related work" means for a contractor versus a fitter…
Gritty Sprinkler FitterPulled Card, Red Tag, Fat Fine — Suspension, Revocation, Civil Penalties and Cease-and-Desist in Minnesota
The disciplinary end of Minn. R. 7512 and Minn. Stat. 299M, start to finish — what gets your license or card revoked, the 7/14/28-day suspension ladder and its…
Gritty Sprinkler FitterCard or Get the Fuck Off the Lift — Journeyman, Conditional, Limited Certs and Apprentices in Minnesota
Two fitters tear through Minn. R. 7512 and Minn. Stat. 299M on who's actually allowed to touch a sprinkler system in Minnesota, from the 8,000-hour exam ticket…
Gritty Sprinkler FitterImpairments and obstruction investigations
Impairments, red tags, and obstruction investigations when the system’s dirty or compromised. Flashcard scenarios plus the paperwork reality.Season 3 · Ep 3MN…
Gritty Sprinkler FitterMain drain, waterflow, and weekly tests
Main drain tests, waterflow alarms, and the weekly/monthly grind. We pull the questions from the study deck and talk through pass/fail the way the exam words…
Gritty Sprinkler FitterSuction, diesel, and the relief valve stuff
Suction supply, diesel drivers, relief valves, and field problems that show up as exam questions. Flashcard answers first, shop talk second - no heroics, no…
Gritty Sprinkler FitterLayout questions that wreck people on the exam
The layout questions that wreck people: mixed rules, trick wording, and the stuff you only catch if you’ve hung pipe and drilled flashcards. We walk the hard…
Gritty Sprinkler FitterReading prints without looking lost
How to read a print so you’re not guessing on the floor. Symbols, elevations, and layout questions from the study set - the ones that separate guessers from…
Gritty Sprinkler FitterDesign density and acceptance testing
Design density, coverage areas, and walking a system through acceptance without waving your hands. We use the actual exam flashcards so density and spacing…
Gritty Sprinkler FitterSeismic bracing — the boring stuff that shows up
Seismic bracing and support details - dry, important, and on the test. Flashcard-driven: what has to be restrained, why, and how the question will try to trick…
Gritty Sprinkler Fitter13D / 13R and the small room rule
Residential and 13R/13D rules that trip people who only ever think full commercial NFPA 13. Small room rule, townhouses, and the gotchas - straight off the…
Gritty Sprinkler FitterStorage, commodity class, and ESFR (don't wing it)
Two fitters grinding the layout side of the MN journeyman exam — how far heads can stretch, where hangers have to land, rod sizes on big pipe, beam and…
Gritty Sprinkler FitterMN Exam Deep Dive — Pumps (Grounded)
## MN Exam Deep Dive — Pumps (Grounded) Multi-art deep dive (3 segments) built from **validated MN exam cards** only. ### Exam editions (ataset) -FPA…
Gritty Sprinkler FitterMN Exam Deep Dive - Standpipe (Grounded)
_Runtime (stitched): ~701.minutes_ ##MN Exam Deep Dive - Standpipe (rounded) **Series:** Season 5- Standpipe (FPA 14) Multi-part deep dive (3 segments)built…
Gritty Sprinkler FitterMN Exam Deep Dive — Safety (Grounded)
_untime (stitched): ~60.4 minutes_ ## MN Exam Deep Dive —Safety (Grounded) **Series:** Season 7— Jobsite safety Multi-part deep dive (3 segments) built from…
Gritty Sprinkler FitterMN Exam Deep Dive — Underground (Grounded)
_ime (titched:) ~53.9 minutes_ ##MN Exam Deep Dive —Underground (rounded ) **Series:** Season 6 —Underground (FPA 2)4 M uti-part deep dive (3segments)built…
Gritty Sprinkler FitterMN Exam Deep Dive — Standpipe (Grounded)
_Runtime (stitched):6~61. minutes_ ## MN Exam Deep Dive — Standpipe (Grounded) **eries:** Season 5 — Standpipe (NFPA 14) Multi-part deep dive (3 segments)…
Gritty Sprinkler FitterMN Exam Deep Dive — Mn Law (Grounded)
_untime (titched): ~6.51 minutes_ ##MN Exam Deep Dive — Mn Law (Grounded) **eries:** Season 4 — MN law /MSFC / licensing Multi-part deep dive (3 segments)built…
Gritty Sprinkler FitterMN Exam Deep Dive — Itm (Grounded)
_Runtime (titched): ~662. minutes_ ##MN Exam Deep Dive — Itm (Grounded) S** eries:** Season 3 — ITM (NFPA 25 )Multi-art deep dive 3( segments) built from…
Gritty Sprinkler FitterMN Exam Deep Dive — Installation (Grounded)
Long-form grounded exam prep on sprinkler installation (NFPA 13 layout, hangers, spacing, obstructions) for Minnesota journeyman sprinkler fitters. Built only…
Gritty Sprinkler FitterMN Exam Deep Dive — Pumps (Grounded)
Long-form grounded exam prep on fire pumps for Minnesota journeyman sprinkler fitters. Built only from validated study cards with pinned exam editions (NFPA…
Gritty Sprinkler FitterStandard Spray Upright and Pendent Sprinklers — Ceiling Clearance, Storage Separation, and Structural Beam Obstructions (The "3-Times Rule")
Look, every fitter on the job site thinks they know how to position heads around steel beams because 'it just looks centered,' but the state examiner doesn't…
Gritty Sprinkler FitterObstructions Installed Entirely Below Sprinklers (The 4-Foot Rule for Overhead Ducts, Decks, and Trays)
Look, every greenhorn on the job thinks if a sheet metal HVAC duct is hanging a couple of feet below the branch line, they can just run their pipe over top of…