Latest / Civil Engineering Made Simple / Joints in steel construction: Simple Connections
Transcript
- 0:00Speaker 1: Welcome back to the deep dive. Today, we are putting
- 0:03Speaker 1: away the big complex structural analysis models. We're going to
- 0:08Speaker 1: focus on the bread and butter of steel construction, the
- 0:10Speaker 1: simple connection. We're diving into some specialized design guides, some
- 0:14Speaker 1: codes to really give you the most critical nuggets for safe,
- 0:18Speaker 1: economical and efficient design.
- 0:20Speaker 2: And that's really the mission, isn't it.
- 0:22Speaker 1: It has to be for anyone working in structural engineering.
- 0:24Speaker 1: This is where theory meets reality, and frankly, it's where
- 0:28Speaker 1: money is either saved or wasted.
- 0:31Speaker 2: It is we are moving past the let's say, basic
- 0:35Speaker 2: academic principles and really distilling the actual design procedures, the
- 0:40Speaker 2: rules of aggressive standardization and those non negotiable structural integrity checks.
- 0:46Speaker 2: Aggressive standardization I like that, well, the overriding economic driver,
- 0:50Speaker 2: and you have to let this dictate every decision you make.
- 0:52Speaker 2: Here is this the cost of the material, So your fittings,
- 0:55Speaker 2: your bolts, it's tiny. It's tiny compared to the cost
- 0:58Speaker 2: of workmanship, time, all that complexity. If you can standardize
- 1:03Speaker 2: and simplify the connections, you slash the project cost, even
- 1:07Speaker 2: if you know you overspect the occasional bolt.
- 1:09Speaker 1: Okay, let's unpack that economic imperative, because it really sounds
- 1:13Speaker 1: like it's the foundation of well everything we're about to discuss. Yeah,
- 1:17Speaker 1: why is standardization so critical that it dictates our material choices?
- 1:22Speaker 2: It's all about a supply chain advantage.
- 1:24Speaker 1: Uh.
- 1:25Speaker 2: If you can limit the range of connection types you
- 1:27Speaker 2: use across an entire project or even just across your
- 1:30Speaker 2: firm's standard details, you just you cut down on inventory,
- 1:34Speaker 2: you simplify ordering, and you speed up the fabrication process dramatically.
- 1:37Speaker 1: So we're talking about a limited palate.
- 1:39Speaker 2: A very limited palette, usually standard flats and angles, you know,
- 1:42Speaker 2: made from S two seventy five grade material. It's just
- 1:45Speaker 2: it's readily available and it's cost effective.
- 1:47Speaker 1: And I imagine that philosophy extends to the core fastener,
- 1:51Speaker 1: the humble bolt. There must be a very specific preference there.
- 1:54Speaker 2: Oh. Absolutely, The universal workhorse and structural steel is the
- 1:57Speaker 2: M twenty grade eight point eight bolt. Here's the key
- 2:00Speaker 2: standardization trick, the inventory trick.
- 2:02Speaker 1: Okay, instead of stocking all these partially threaded bolts in
- 2:06Speaker 1: various lengths, the recommendation is to use fully threaded bolts.
- 2:10Speaker 2: So technically screws.
- 2:11Speaker 1: Technically screws, yes, in some standards, but you use them
- 2:15Speaker 1: as the default.
- 2:17Speaker 2: And how far does that one simple change actually take us.
- 2:20Speaker 1: The sources suggest that a single bolt type, say an
- 2:23Speaker 1: M twenty by sixty mili long grade eight point eight
- 2:26Speaker 1: fully threaded bolt, that can competently handle up to ninety
- 2:31Speaker 1: percent of the symbol connections in a typical multi story frame.
- 2:35Speaker 2: Ninety percent. That's a huge simplification.
- 2:37Speaker 1: It's massive for stock management.
- 2:39Speaker 2: Well, wait a second, if you're using fully threaded bolts,
- 2:41Speaker 2: doesn't that mean the threads are more likely to be
- 2:43Speaker 2: in the sheer plane they are. Sounds like it reduces
- 2:46Speaker 2: the capacity compared to using the smooth shank.
- 2:48Speaker 1: It does, but we account for that conservatively to ensure
- 2:51Speaker 1: safety across the board, and you know, maintain that inventory simplicity.
- 2:55Speaker 1: All the standard capacity tables assume that the threads are
- 2:58Speaker 1: always in the sheer plane when you're calculating the bolt
- 3:01Speaker 1: shear capacity.
- 3:01Speaker 2: I see, So you just take the hit on capacity
- 3:03Speaker 2: you do. It simplifies the design check process because now
- 3:06Speaker 2: you only need one set of capacity tables for that
- 3:09Speaker 2: bolt diameter in grade.
- 3:10Speaker 1: So the economic driver dictates the technical specification and we
- 3:14Speaker 1: just absorb a minor technical penalty for a massive gain in.
- 3:18Speaker 2: Efficiency precisely and alongside those bolts. Of course, you need
- 3:21Speaker 2: standardized fittings, so we standardize the geometry of the plates
- 3:25Speaker 2: and angles. Think standard flats like one hundred by ten
- 3:28Speaker 2: or one hundred and fifty by eight, angles like ninety
- 3:30Speaker 2: by ninety by ten again almost universally in S two
- 3:34Speaker 2: seventy five steel and the.
- 3:35Speaker 1: Welds, the things attaching these components.
- 3:37Speaker 2: For welds, we opt for small single pass filelet welds,
- 3:41Speaker 2: typically using E thirty five electrodes.
- 3:43Speaker 1: Why the preference for small single pass welds.
- 3:46Speaker 2: It's all about fabrication, speed and quality control. Small filet
- 3:50Speaker 2: welds avoid the need for time consuming edge preparation, and
- 3:53Speaker 2: this is crucial. They minimize the requirement for non destructive.
- 3:57Speaker 1: Testing, which is another huge costs.
- 3:59Speaker 2: It's another signify again hit to the workmanship. Cost, speed
- 4:02Speaker 2: and simplicity. Those are the watchwords.
- 4:04Speaker 1: Let's shift gears a little. What happens when we can't
- 4:06Speaker 1: get behind the support member to install a nut. I'm
- 4:10Speaker 1: thinking like connecting to rectangular holow sections rhs. You mentioned
- 4:14Speaker 1: specialized systems.
- 4:15Speaker 2: Right connections to rahs and other close sections. They demand
- 4:18Speaker 2: innovative solutions because you often only have access from one
- 4:22Speaker 2: side from the exterior, So.
- 4:23Speaker 1: What do you do?
- 4:24Speaker 2: One solution is flow drill. It's a thermal process. A
- 4:28Speaker 2: rotating tool generates a ton of heat and friction. It
- 4:32Speaker 2: softens the steel and it creates this little bushing like
- 4:35Speaker 2: a collar of material.
- 4:36Speaker 1: You tap that.
- 4:37Speaker 2: You then tap that to create a threaded hole directly
- 4:39Speaker 2: in the RHS wall and that lets you use a
- 4:42Speaker 2: standard fully threaded bolt.
- 4:44Speaker 1: That's fascinating, like creating a stronger connection point in thin
- 4:47Speaker 1: seal without needing to weld on a stiffener.
- 4:49Speaker 2: That's a great way to put it.
- 4:51Speaker 1: What's the other major specialized solution.
- 4:53Speaker 2: That would be the haulobolt. It's a single sided fixing method,
- 4:56Speaker 2: basically an expansion bolt designed specifically for this and assert it.
- 5:00Speaker 2: You tighten it from the outside and the assembly expands
- 5:03Speaker 2: and grips the interior face.
- 5:05Speaker 1: Any practical notes on that for engineers.
- 5:07Speaker 2: Yes, the larger sizes, so you're M sixteen and M
- 5:10Speaker 2: twenty hollow bolts, they require a five part assembly to
- 5:14Speaker 2: ensure a proper secure fixing. You have to be very
- 5:17Speaker 2: detail oriented when you're specifying them.
- 5:19Speaker 1: That really sets the stage for our core design elements
- 5:22Speaker 1: let's move to the three primary simple beam connection types.
- 5:25Speaker 1: That I mean they dominate any steel frame, double angle
- 5:28Speaker 1: webcleatsas flexible mplates, feps, YEP and fin plates or FPS
- 5:34Speaker 1: that trio.
- 5:36Speaker 2: That's the vast majority of simple connections, and what unites them,
- 5:39Speaker 2: regardless of their geometry is the foundational design objective. They
- 5:43Speaker 2: must be detailed to develop only nominal moments, so.
- 5:46Speaker 1: You're intentionally designing them to be flexible.
- 5:48Speaker 2: Intentionally flexible. You need to ensure they have sufficient ductility
- 5:52Speaker 2: and rotational capacity so they behave predictably as pinned joints
- 5:56Speaker 2: rather than accidentally caring unforeseen moments they were never designed for.
- 6:00Speaker 1: Okay, let's start with DAX double angle web cleats. The
- 6:03Speaker 1: angles are attached to the supporting member and the beam web.
- 6:06Speaker 1: How do we ensure that necessary rotational capacity and provides stability.
- 6:10Speaker 2: Well, the rotational capacity comes from the flexing of those
- 6:14Speaker 2: thin angle cleats. They're typically eight millimeter or ten millimeter thick.
- 6:19Speaker 2: Stability specifically the torsional restraint for the supported beam. That's
- 6:23Speaker 2: achieved through a really crucial geometric requirement, which is the
- 6:27Speaker 2: length of the queat. Let's call it more dollars must
- 6:30Speaker 2: be at least zero point six times the depth of
- 6:32Speaker 2: the supported beam, so lardas is greater than or equal
- 6:35Speaker 2: to point sixty.
- 6:36Speaker 1: And if the cleat is too short.
- 6:38Speaker 2: If it's too short, the beam is not adequately restrained
- 6:41Speaker 2: against twisting. Simple as that.
- 6:42Speaker 1: In terms of strength, when we look at a deconnection,
- 6:45Speaker 1: what's usually the weakest link in the chain.
- 6:47Speaker 2: For most standard setups, especially with a single vertical line
- 6:51Speaker 2: of bolts, the connection's capacity is it's rarely governed by
- 6:55Speaker 2: the strength of the bolts themselves. In share, it's almost
- 6:57Speaker 2: always governed by.
- 6:58Speaker 1: Check four and check four is four.
- 7:00Speaker 2: Is bolt bearing on the supported beam?
- 7:02Speaker 1: Web? Bolt bearing? Okay, help our listener visualize that is
- 7:05Speaker 1: the bolt itself failing or is it the material around
- 7:09Speaker 1: the bolt?
- 7:09Speaker 2: It's the material failing locally. The perfect visualization is the
- 7:14Speaker 2: hole stretching out. It becomes an oval or a kidney
- 7:17Speaker 2: shape underload. That local compression failure on the web steel
- 7:21Speaker 2: the wab of the supported beam. That's what limits the
- 7:24Speaker 2: connection capacity.
- 7:25Speaker 1: Which is why DAGs often cap out around what fifty
- 7:28Speaker 1: percent of the beam's total sheer capacity?
- 7:30Speaker 2: Exactly right, That's the limiting factor.
- 7:32Speaker 1: That makes perfect sense now let's compare that to the
- 7:35Speaker 1: flexible endplate the FEP. These are shop welded to the beam,
- 7:38Speaker 1: which sounds great for quality control is but then they
- 7:41Speaker 1: site bolted to the column.
- 7:43Speaker 2: Feps get their flexibility the same way dex to Thinness,
- 7:47Speaker 2: we use eight or ten mil plates and again that
- 7:49Speaker 2: plate depth must be at least point six times the
- 7:52Speaker 2: supported beam depth to ensure the rotational capacity we need.
- 7:55Speaker 1: But now here's the big practical trade off, isn't it
- 7:57Speaker 1: site tolerance. If I choose an FVP, I avoid welding
- 8:01Speaker 1: on site, but I introduce a tolerance problem.
- 8:03Speaker 2: Exactly. This is the fabrication trade off. Unlike a DC,
- 8:06Speaker 2: which can kind of accommodate minor length variances because the
- 8:09Speaker 2: cleat's flex and adjust the rigid FVP has very little
- 8:13Speaker 2: room for site adjustment.
- 8:14Speaker 1: So if you have a long run of beams.
- 8:15Speaker 2: If you have a long run of beams, those dimensional
- 8:18Speaker 2: tolerances accumulate very quickly. The professional solution is to deliberately
- 8:22Speaker 2: detail shorter beams at specific regular intervals, say every fifth beam,
- 8:28Speaker 2: and then use packs or shims to fill the gap.
- 8:31Speaker 1: And you have to specify that.
- 8:32Speaker 2: You must instruct the fabricator to minimize the number of packs,
- 8:35Speaker 2: ideally fewer than four.
- 8:37Speaker 1: Okay, moving on to fin plates FPS. Here the plate
- 8:41Speaker 1: is welded to the supporting column and site bolted to
- 8:43Speaker 1: the beam web. How do they generate rotation if they're
- 8:47Speaker 1: basically a single rigid element just sticking out well.
- 8:50Speaker 2: The rotation mechanism is distributed across several elements, which is
- 8:53Speaker 2: really fascinating. It comes from the combined deformation of the
- 8:57Speaker 2: bolt group undergoing sheer, the out of plane bending of
- 9:02Speaker 2: the fin plate itself, and critically, the inevitable whole distortion.
- 9:06Speaker 1: That ovilization we just talked.
- 9:07Speaker 2: About exactly, the ovilization in both the plate and the
- 9:10Speaker 2: beam web. All three of those contribute to the required
- 9:12Speaker 2: rotational capacity.
- 9:13Speaker 1: We classify these plates is either short or long. What
- 9:16Speaker 1: defines the difference and why does it matter? Practically?
- 9:19Speaker 2: On site, it's defined by the ratio of the fin
- 9:22Speaker 2: plate thickness two dollars to the distance between the bolt
- 9:25Speaker 2: line and the face of the support So if t
- 9:28Speaker 2: dollars over all or is greater than or equal too
- 9:30Speaker 2: point one five, it's a short fin plate, and.
- 9:34Speaker 1: If it's less, it's a long fin.
- 9:35Speaker 2: Play correct, and the practical difference is crucial. Short fin
- 9:39Speaker 2: plates often require the fabricator to trim the bottom flange
- 9:43Speaker 2: of the supported beam just to provide physical access.
- 9:46Speaker 1: For the wrench, oh for the bolting process.
- 9:48Speaker 2: For the bolting process, and that adds complexity and cost
- 9:51Speaker 2: to fabrication.
- 9:52Speaker 1: So if I'm optimizing for pure economy, I'm probably aiming
- 9:56Speaker 1: for long fin plates to avoid that trimming. Assuming that
- 9:59Speaker 1: geom works out, that would be the goal. And what
- 10:02Speaker 1: usually governs the strength of a fin plate connection.
- 10:04Speaker 2: For a standard geometry, You're typically looking at either check two,
- 10:08Speaker 2: which is bolt bearing again, or check three, which is
- 10:11Speaker 2: the combined sheer and bending capacity of the fin plate itself.
- 10:14Speaker 2: The efficient designer has to quickly figure out which of
- 10:17Speaker 2: those two is likely to govern their design.
- 10:19Speaker 1: This brings us nicely to the comprehensive design philosophy. You
- 10:23Speaker 1: mentioned earlier that there's a sort of three stage check
- 10:25Speaker 1: process for all simple connections. Let's just review that. Okay.
- 10:29Speaker 2: Stage one is conceptual ensure you're detailing so your geometry,
- 10:33Speaker 2: your thickness, your cleat length guarantees that the connection achieves
- 10:36Speaker 2: nominal moments and the ductility.
- 10:38Speaker 1: You need stage two.
- 10:39Speaker 2: Stage two is identifying the load path. You have to
- 10:42Speaker 2: track the load from the beam through the bolts, into
- 10:44Speaker 2: the plate, through the walls, and then into the support.
- 10:47Speaker 1: And stage three is the number crunching.
- 10:49Speaker 2: That's the majority of your calculations. You're checking the strength
- 10:52Speaker 2: of every single component along that load path against failure,
- 10:55Speaker 2: which involves numerous specific checks just for vertical shear alone.
- 11:00Speaker 1: Beyond vertical sheer strength, we get into the realm of
- 11:04Speaker 1: non serviceability checks, specifically checks eleven through fifteen related to
- 11:09Speaker 1: structural integrity. This is something that I think is often
- 11:13Speaker 1: misunderstood by new engineers, but it's a critical safety net.
- 11:16Speaker 2: It is the safety net. This requirement, it's codified in
- 11:19Speaker 2: standards like BS fifty nine to fifty one, and it
- 11:22Speaker 2: addresses the risk of disproportionate collapse.
- 11:24Speaker 1: Right. So if one localized failure happens, say a supporting
- 11:29Speaker 1: column gets damaged by an impact.
- 11:31Speaker 2: We need to ensure the building doesn't just unravel completely.
- 11:34Speaker 2: The code mandates that all floor beamed column connections must
- 11:38Speaker 2: be detailed to resist a minimum tying force of at
- 11:40Speaker 2: least seventy five kilin nutants.
- 11:43Speaker 1: And this seventy five kill in force is a pure
- 11:45Speaker 1: tension check performed in isolation. It's not combined with your
- 11:48Speaker 1: normal vertical service loads.
- 11:50Speaker 2: That's a vital point. It's an ultimate tensile safety measure. Now,
- 11:54Speaker 2: while seventy five killing in sounds substantial, the good news
- 11:57Speaker 2: is that empirical test data suggests that even the smallest,
- 12:00Speaker 2: most practical DAC and FVP connections inherently have a much
- 12:04Speaker 2: higher tying capacity.
- 12:05Speaker 1: I think I saw a number for that.
- 12:07Speaker 2: We've seen tests where the smallest d DAY failed at
- 12:09Speaker 2: one hundred and seventy eight kl in. However, many engineers
- 12:12Speaker 2: leveraged the structural slab. If you're using a composite floor system,
- 12:16Speaker 2: the rebar within the concrete slab is often relied upon
- 12:19Speaker 2: to carry those time forces.
- 12:20Speaker 1: Which simplifies the steel connection design.
- 12:22Speaker 2: Greatly and it saves money.
- 12:24Speaker 1: Let's talk about a crucial cautionary tale, one that really
- 12:27Speaker 1: highlights why learning from technical corrections is so important. Yeah,
- 12:30Speaker 1: the finplate corrigendum.
- 12:31Speaker 2: This is an essential lesson in professional competence. Core gendom
- 12:35Speaker 2: one for fin plates corrected a very serious flaw in
- 12:38Speaker 2: the original design tables for finn plates with a single
- 12:42Speaker 2: vertical line of bolts. The original tabulated tying capacity.
- 12:46Speaker 1: The ability to resist that seventy five killer and tension.
- 12:48Speaker 2: Yes, they were based on checks that entirely excluded the
- 12:52Speaker 2: sheer capacity of the bowl group itself.
- 12:54Speaker 1: You're kidding, meaning that if the tension was high, the
- 12:57Speaker 1: bolts could just sheer off before the plane even reach
- 13:00Speaker 1: its capacity.
- 13:01Speaker 2: Exactly. The bolt group acting in sheer could be the
- 13:04Speaker 2: weakest link in that longitudinal load path, but it was
- 13:07Speaker 2: being ignored. If the bolts failed, the tie failed, potentially
- 13:11Speaker 2: leading to the exact collapse scenario the check was designed
- 13:14Speaker 2: to prevent.
- 13:15Speaker 1: So what's the fix? What do we do now?
- 13:18Speaker 2: The solution and the rule you must follow now is
- 13:21Speaker 2: the inclusion of an additional integrity check check thirteen. This
- 13:25Speaker 2: just verifies that the applied tie force is less than
- 13:27Speaker 2: or equal to the total sheer capacity of the bolt
- 13:30Speaker 2: group non on time's plar dollars. It ensures the bolts
- 13:33Speaker 2: won't be the point of catastrophic failure under tension.
- 13:36Speaker 1: That dramatically reinforces the value of diligence in design. Let's
- 13:40Speaker 1: briefly look at a few specialized connections, starting with column
- 13:44Speaker 1: splices bearing versus non bearing. What's the fundamental difference in
- 13:49Speaker 1: the load path?
- 13:49Speaker 2: Well bearing splices are the preferred choice because the ends
- 13:52Speaker 2: of the columns are machined to fit tightly together. This
- 13:55Speaker 2: allows the column shafts to bear directly against each.
- 13:58Speaker 1: Other, so the compression goes straight through.
- 14:00Speaker 2: The bulk of the Axial compression goes straight through the
- 14:02Speaker 2: flange cover plates and bolts. Then just handle residual forces
- 14:06Speaker 2: like net tension or any minor moments and non bearing.
- 14:10Speaker 2: Non bearing splices have a physical gap. That means all
- 14:13Speaker 2: the forces compression, tension, and moment have to be transferred
- 14:16Speaker 2: entirely through the splice plates and the bolts. It requires
- 14:19Speaker 2: much larger and more complex connections.
- 14:22Speaker 1: And how does that seventy five kiloman tie requirement apply
- 14:25Speaker 1: to a column splice?
- 14:26Speaker 2: If structural integrity is required, the flange cover plates have
- 14:30Speaker 2: to be checked to resist a tensile force equal to
- 14:33Speaker 2: half the specified tying force. So up divided by two,
- 14:37Speaker 2: it's a conservative assumption that the tie force is just
- 14:40Speaker 2: distributed equally to the two flanges.
- 14:42Speaker 1: Moving down to the foundation column bases, specifically slab bases,
- 14:48Speaker 1: what are the key design assumptions there?
- 14:50Speaker 2: Slab bases are typically designed assuming they're subject only to
- 14:53Speaker 2: axial compression and vertical shear. The primary goal is to
- 14:57Speaker 2: size the base plate so it transfers the low to
- 15:00Speaker 2: the concrete foundation without exceeding the concrete's local bearing capacity, and.
- 15:05Speaker 1: For that we use the effective area method.
- 15:06Speaker 2: We do we check for size, which is check one,
- 15:09Speaker 2: and then for plate thickness, which is check two.
- 15:11Speaker 1: What about the practical logistics for actually installing these things?
- 15:15Speaker 2: A simple geometric rule is to make the base plate
- 15:17Speaker 2: at least one hundred millimeters larger all around than the
- 15:20Speaker 2: column section and crucially, the holding down bolts typically M
- 15:25Speaker 2: twenty four grade four point six. They must be set
- 15:28Speaker 2: in location tubes.
- 15:29Speaker 1: Why tubes for adjustment.
- 15:30Speaker 2: For adjustment, these tubes need to be large, at least
- 15:33Speaker 2: one hundred millimeters in diameter or three times the bolt diameter,
- 15:36Speaker 2: to give the steel erectors enough wiggle room to accurately
- 15:39Speaker 2: plumb and position the column before the base plate is
- 15:42Speaker 2: grounded in place.
- 15:43Speaker 1: Right. Finally, bracing connections. They're vital for erection stability. What
- 15:49Speaker 1: is the role of that kidney slot we so often
- 15:51Speaker 1: see in gusset plates.
- 15:53Speaker 2: The kidney shaped slot is a purely practical detail. It's
- 15:56Speaker 2: formed in the gusset plate to accommodate the inevitable variances
- 15:59Speaker 2: in lane and angle of the bracing members themselves. It
- 16:03Speaker 2: just allows for necessary rotation and adjustment during erection.
- 16:07Speaker 1: But using that slot has direct capacity implications, doesn't it.
- 16:10Speaker 2: It absolutely does. For connection using two bolts where one
- 16:14Speaker 2: whole is a kidney slot, the codes require a reduction
- 16:17Speaker 2: in the calculated capacity. The total shear capacity is taken
- 16:21Speaker 2: conservatively as one point six times plan Cement the single
- 16:25Speaker 2: bolt shear capacity and bear and the total bearing capacity
- 16:28Speaker 2: as one point five times Plan Mizzi. But the most
- 16:30Speaker 2: critical limitation is conceptual. Because that slot allows rotational freedom.
- 16:35Speaker 2: You cannot assume the connection provides directional restraint when you're
- 16:38Speaker 2: calculating the effective length of the bracing member, so.
- 16:41Speaker 1: You have to model this rotational allowance.
- 16:43Speaker 2: You must.
- 16:44Speaker 1: That is a phenomenal synthesis of the core principles of
- 16:47Speaker 1: simple connections, linking every single technical choice back to either
- 16:51Speaker 1: economic efficiency or structural integrity.
- 16:53Speaker 2: The essential takeaway for you, the designer, is that simple
- 16:57Speaker 2: connections are well there, anything but simple to ch They
- 17:00Speaker 2: require detailed rigor by moving from simply picking a member
- 17:04Speaker 2: size to truly understanding the load paths and the failure
- 17:07Speaker 2: modes within the joint elements and constantly learning from technical
- 17:11Speaker 2: amendments like that finplate core agendum. That's how you elevate
- 17:14Speaker 2: your professional practice and ensure true safety and economy in
- 17:17Speaker 2: your designs.
- 17:19Speaker 1: An excellent thought to leave on before we wrap up
- 17:21Speaker 1: this deep dive. Here's a concept for you to apply
- 17:23Speaker 1: immediately and really cement this knowledge. A flexible endplate connection
- 17:28Speaker 1: uses a thin ten milimeters plate to achieve flexibility when
- 17:31Speaker 1: you're checking the component strength for a beam to column connection.
- 17:34Speaker 1: What is the crucial structural concept that governs checks eleven
- 17:37Speaker 1: through fifteen and what minimum force value is typically associated
- 17:41Speaker 1: with this check? Thank you for joining us for the
- 17:43Speaker 1: deep dive. We'll see you next time.