Latest / Pharmacy Made Simple / Accurate Results in the Clinical Laboratory: A Guide to Error Detection and Correction
Transcript
- 0:00Speaker 1: Welcome to the deep dive. Today. We're really getting into
- 0:03Speaker 1: the weeds of clinical laboratory testing. Our mission. It's not
- 0:07Speaker 1: just about looking at numbers on a report. It's about
- 0:10Speaker 1: figuring out all those complex things, the factors that turn
- 0:15Speaker 1: that raw data into genuinely useful clinical information.
- 0:19Speaker 2: That's exactly it information, not just data. Because for you listening,
- 0:23Speaker 2: whether you're a pharmacy student, maybe a young professional just
- 0:26Speaker 2: starting out, or even learning on your own, getting the
- 0:29Speaker 2: most clinical value means you have to understand the test itself.
- 0:32Speaker 2: You know its strengths, it's weaknesses, not just the final
- 0:35Speaker 2: number it spits out right.
- 0:37Speaker 1: And to do that properly, we need to look at
- 0:38Speaker 1: the whole journey of that test sample. Our sources break
- 0:42Speaker 1: this down really nicely into three main stages where things
- 0:44Speaker 1: can well go wrong. It gives us a good framework.
- 0:48Speaker 2: You've got the pre analytical phase first, it's everything before
- 0:51Speaker 2: the actual analysis, so ordering the test, getting the patient ready,
- 0:53Speaker 2: the collection itself, transport all of that. Then Phase two
- 0:57Speaker 2: is the analytical phase. That's the technical part, the actual
- 1:00Speaker 2: measurement happening inside the lab equipment, the assay itself exactly.
- 1:04Speaker 2: And finally, the post analytical phase. This covers getting the
- 1:08Speaker 2: results transmitted correctly, and crucially, how that information gets used
- 1:12Speaker 2: or sometimes misused in clinical decisions.
- 1:15Speaker 1: And it's important to touch on liability early, isn't it,
- 1:18Speaker 1: Because often errors that happened before or after the lab
- 1:21Speaker 1: touches the sample still get called lab errors.
- 1:24Speaker 2: They do quite often. But you know, the lab staff
- 1:27Speaker 2: themselves usually aren't legally liable for those specific pre collection
- 1:31Speaker 2: or post reporting mistakes. Their role becomes more about education,
- 1:35Speaker 2: educating who, educating the people involved in those steps. The
- 1:38Speaker 2: doctor's ordering, the phlebotomists drawing the blood. The lab needs
- 1:41Speaker 2: to help them understand why the error happened to stop
- 1:44Speaker 2: it from happening. Again, it's really about proactive safety.
- 1:47Speaker 1: Got it, Okay, So let's build this out Segment one,
- 1:50Speaker 1: the pre analytical fortress as we're calling it. Standardization seems
- 1:54Speaker 1: key here, so especially here tracking a patient over time,
- 1:57Speaker 1: comparing results. If those collection steps aren't.
- 2:00Speaker 2: Consistent, you lose the signal in the noise. Any real
- 2:03Speaker 2: trend gets buried if the collection varies wildly each time. Again,
- 2:07Speaker 2: we're after information, not just random data points.
- 2:10Speaker 1: So what's the absolute biggest risk in this phase? The
- 2:13Speaker 1: one thing that can have the most severe.
- 2:15Speaker 2: Consequences, hands down, it's patient identification error, getting the sample
- 2:19Speaker 2: tied to the wrong person. The potential outcomes there are
- 2:22Speaker 2: incredibly serious. I think transfusion reactions potentially fatal.
- 2:28Speaker 1: Wow.
- 2:28Speaker 2: Yeah, health systems put a lot of effort into minimizing this,
- 2:32Speaker 2: things like point of care barcode scanning systems right at
- 2:35Speaker 2: the bedside. But it's a constant battle.
- 2:37Speaker 1: Okay, assuming we've got the right patient. What about handling
- 2:40Speaker 1: the sample itself. You mentioned it's like a minefield.
- 2:42Speaker 2: It can be common failures well. Sample container and filling
- 2:46Speaker 2: errors are frequent. Using the wrong type of tube, maybe
- 2:49Speaker 2: one with the wrong additive or preservative.
- 2:51Speaker 1: Or just not getting enough blood.
- 2:53Speaker 2: Exactly, insufficient quantity, or maybe the tube is empty or
- 2:56Speaker 2: missing entirely. Then there's contamination. The big one is drawing
- 3:01Speaker 2: blood from an arm with an IV running your planet.
- 3:03Speaker 2: You can taminate the sample with the infusion fluid or
- 3:06Speaker 2: microbial contamination. Yeah. Transport and processing issues too, keeping it
- 3:11Speaker 2: at the wrong temperature, leakage during transit, Maybe the sample
- 3:14Speaker 2: gets damaged when they spin it down on the centrifuge.
- 3:17Speaker 2: Lots of potential pitfalls.
- 3:19Speaker 1: You mentioned spinning it down time must be a factor here,
- 3:21Speaker 1: right for samples to build it.
- 3:23Speaker 2: Oh, absolutely critical. The CLSI guidelines, that's the Clinical and
- 3:27Speaker 2: Laboratory Standards Institute, they give a clear recommendation you need
- 3:31Speaker 2: to separate the plasma or serum from the blood cells
- 3:35Speaker 2: within two hours of collection.
- 3:36Speaker 1: Two hours why so critical.
- 3:38Speaker 2: Because if you wait longer, stuff starts leaking out of
- 3:41Speaker 2: the cells into the serum or plasma. We're talking intracellular
- 3:44Speaker 2: components like potassium, phosphate, magnesium, even enzymes like lactate dehydrogenase.
- 3:50Speaker 1: So if you see a surprisingly high potassium level before
- 3:54Speaker 1: jumping to kidney problems, you should check if the sample
- 3:57Speaker 1: processing was delayed.
- 3:58Speaker 2: That should definitely be on your checklist. Could easily be
- 4:00Speaker 2: a pre analytical issue, not a physiological one. A huge
- 4:04Speaker 2: potential misdirection.
- 4:05Speaker 1: That makes sense. What about the type of sample whole
- 4:08Speaker 1: blood versus serum or plasma.
- 4:10Speaker 2: Generally for things like cellular components, vitamins, trace elements, we
- 4:15Speaker 2: prefer whole blood. It often gives a better picture of
- 4:18Speaker 2: what's actually in the tissues compared to just serum or
- 4:20Speaker 2: plasma alone.
- 4:22Speaker 1: Okay, let's talk anticoagulants in this strict order of draw
- 4:26Speaker 1: the ofd you mentioned additives. This order is designed to
- 4:29Speaker 1: stop them from messing up other tests.
- 4:31Speaker 2: Precisely, anticoagulants, especially the liquid ones, need to be in
- 4:35Speaker 2: the right proportion to the blood. Too little, you get clots,
- 4:38Speaker 2: too much, you dilute the sample. And the order of
- 4:41Speaker 2: draw sequence is specifically designed to minimize the risk of
- 4:43Speaker 2: an additive from one tube carrying over and contaminating the
- 4:47Speaker 2: sample in the next tube drawn.
- 4:48Speaker 1: Can you walk us through that order quickly?
- 4:50Speaker 2: Sure? It generally goes first sterile tubes for blood cultures,
- 4:54Speaker 2: then tubes for trace elements, usually non additive. Next are
- 4:57Speaker 2: the citrate tubes for coagulation tests, followed by serum tubes
- 5:01Speaker 2: which might have a clod activator or gel but no anticoagulant.
- 5:05Speaker 2: Then come the heperin tubes. After that the EDTA tubes.
- 5:09Speaker 1: Ah EDTA. You flagged that one earlier. It causes problems
- 5:12Speaker 1: if it contaminates other tubes.
- 5:14Speaker 2: It's the classic example. Yeah, if someone draws an EDTA
- 5:17Speaker 2: tube before say a serum tube or heperin tube meant
- 5:20Speaker 2: for chemistry tests, the EDTA itself, which contains potassium, can
- 5:24Speaker 2: get into that next.
- 5:25Speaker 1: Tube, and that causes.
- 5:27Speaker 2: Spurious results, very specific ones. It leads to falsely high
- 5:32Speaker 2: potassium levels hypercolemia because you've added potassium edta, and it
- 5:36Speaker 2: falsely lowers calcium and magnesium levels, hypocalcemia, hypomagnesemia because edth
- 5:42Speaker 2: Hailot's or binds those ions.
- 5:44Speaker 1: So a simple mistake in the drawing order can create
- 5:47Speaker 1: this completely falls quite alarming biochemical pictures exactly.
- 5:53Speaker 2: It looks like a serious metabolic issue, but it's just
- 5:55Speaker 2: a mechanical error during collection. It really hammers home how
- 5:59Speaker 2: vital the pre analytical phases.
- 6:01Speaker 1: Absolutely. Okay, let's shift to gears now segment two. Considering
- 6:05Speaker 1: the patient context. We've got a good sample handled correctly,
- 6:08Speaker 1: but the patient themselves brings a whole lot of complexity.
- 6:11Speaker 2: Right, we have to stop looking at lab results in
- 6:13Speaker 2: a vacuum. A number falling within the normal reference range
- 6:17Speaker 2: is an automatically normal for that specific patient. What do
- 6:19Speaker 2: you mean, Well, think about biological variation. A significant change
- 6:23Speaker 2: for an individual might happen entirely within that reference interval.
- 6:27Speaker 2: Maybe they usually run at the low end and now
- 6:29Speaker 2: they're at the high end. That shift could be clinically important,
- 6:32Speaker 2: even if both values are normal.
- 6:34Speaker 1: Okay, That's a subtle but important point, and patient preparation
- 6:37Speaker 1: is part of this context too.
- 6:39Speaker 2: Like fasting, definitely, fasting is non negotiable for certain tests
- 6:44Speaker 2: like lipids, zeramron, and especially glucose, where we have a
- 6:47Speaker 2: pretty tight target range usually seventy to one hundred and
- 6:50Speaker 2: ten MILIGEDL. But here's an interesting bit. If someone fasts
- 6:54Speaker 2: for too long, say over forty eight hours, their body
- 6:57Speaker 2: ramps up fat metabolism, keytone bodies, acid tone, aceto acetate,
- 7:01Speaker 2: beta hydroxybic acid can shoot up maybe thirty fold, and.
- 7:04Speaker 1: They can interfere with some tests right which.
- 7:05Speaker 2: We'll get to exactly. It affects certain essays, particularly some
- 7:09Speaker 2: creatinine methods.
- 7:10Speaker 1: Let's talk age as well. Physiology changes dramatically across the lifespan.
- 7:14Speaker 1: How does that impact common lab results hugely?
- 7:17Speaker 2: Take newborns, they often have high billy rubin because their
- 7:20Speaker 2: liver isn't fully mature yet it can't efficiently process it.
- 7:23Speaker 2: Their kidney function, the GFR is also lower initially, and
- 7:27Speaker 2: kids during childhood you see expected to increases in things
- 7:31Speaker 2: like alkaline phosphatase ALP because of bone growth. Also creatanine
- 7:35Speaker 2: related to increasing muscle mass and growth hormone of course.
- 7:39Speaker 1: Okay, Now what about the other end of the spectrum,
- 7:41Speaker 1: the geriatric population, say, over sixty five, what's the big
- 7:44Speaker 1: trap when we look at their kidney function tests.
- 7:47Speaker 2: This is absolutely critical, especially for anyone involved in medication
- 7:50Speaker 2: dosing after age sixty or so. Kidney function the GFR
- 7:54Speaker 2: naturally declines, maybe by thirty forty percent, that's just aging.
- 7:57Speaker 1: But their creatinine might look normal.
- 8:00Speaker 2: That's the trap. Older patients, particularly if their frail, often
- 8:04Speaker 2: have sycopenialless muscle mass. Since creatinine comes from muscle breakdown,
- 8:08Speaker 2: they produce less creatinine, so their serum creatinine level and
- 8:12Speaker 2: maybe their BUN two can stay within the normal reference
- 8:16Speaker 2: range even when their actual kidney clearance is significantly reduced.
- 8:19Speaker 1: Wow. So relying solely on that normal creatinine in an older,
- 8:23Speaker 1: frail patient could lead you to overestimate their kidney function.
- 8:27Speaker 2: Quite badly dangerously. So yes, it has major implications for
- 8:31Speaker 2: dosing drugs that are cleared by the kidneys. You could
- 8:34Speaker 2: easily overdose someone if you don't account for this discrepancy.
- 8:37Speaker 1: That's a fantastic clinical pearl. Okay, let's dig into diet
- 8:41Speaker 1: and even herbal stuff. Caffeine seems pretty harmless.
- 8:44Speaker 2: Well, pharmacologically it does quite a bit. It triggers the
- 8:47Speaker 2: release of cateacholamines and cortisol. This ramps up gluconeogenesis, so
- 8:51Speaker 2: it can raise blood glucose levels. But here's a really
- 8:54Speaker 2: specific interference. Caffeine can cause falsely high ionized calcium. Wow,
- 9:01Speaker 2: it acutely lowers blood pH slightly. This change causes more
- 9:05Speaker 2: calcium to detach from proteins like albumin, increasing the free
- 9:09Speaker 2: or ionized fraction that the electrode measures so it looks
- 9:12Speaker 2: higher than the true total body calcium status. Might suggest interesting.
- 9:16Speaker 1: Okay, what about liquorice? Not just candy?
- 9:18Speaker 2: Apparently definitely not just candy. Real liquors contains a compound
- 9:21Speaker 2: called glycerizenic acid, and this acid is a potent inhibitor
- 9:25Speaker 2: of an enzyme called a eleven beta hydroxystorid dehydrogenase.
- 9:28Speaker 1: Okay, what does blocking that enzyme do?
- 9:31Speaker 2: It basically prevents the breakdown of cortisol in tissues like
- 9:34Speaker 2: the kidney. This allows cortisol, which normally has minimal mineral
- 9:39Speaker 2: or corticoid effect, to act like aldosterone. The result, the
- 9:43Speaker 2: body retains salt and water, and critically it wastes potassium,
- 9:47Speaker 2: leading to hypocalmia.
- 9:48Speaker 1: Low potassium levels and that's dangerous.
- 9:50Speaker 2: Extremely dangerous, especially for patients taking digoxin. Low potassium dramatically
- 9:56Speaker 2: increases the risk of digoxin toxicity, which can be fatal.
- 10:00Speaker 2: There are case reports of people eating large amounts of
- 10:02Speaker 2: liquorice ending up paralyzed with potassium levels down at like
- 10:06Speaker 2: one point eight millima, life threateningly low.
- 10:09Speaker 1: Goodness, It really shows you need to ask about everything
- 10:12Speaker 1: a patient might be consuming.
- 10:13Speaker 2: Absolutely, patient education on these things is vital.
- 10:16Speaker 1: Okay, let's move into the lab itself Segment three, the
- 10:19Speaker 1: analytical phase. Even with a perfect sample from a well
- 10:22Speaker 1: understoed patient, the testing technology isn't full proof.
- 10:25Speaker 2: No measurement is perfect. There's always some potential for error.
- 10:29Speaker 2: Let's take creatine again. The classic method, the Jaffre reaction
- 10:32Speaker 2: is still widely used, but known to have issues.
- 10:35Speaker 1: What kind of issues?
- 10:36Speaker 2: It's prone to interference. It reacts not just with creatinine,
- 10:39Speaker 2: but with other substances we call them noncreatinine chromogens that
- 10:43Speaker 2: can make the creatinine level look falsely high, like what well,
- 10:47Speaker 2: very high glucose levels over three hundred MILIGDL. Certain antibiotics
- 10:51Speaker 2: like the cephalosporin syphoxetin, but the big one clinically is acetoacetate,
- 10:56Speaker 2: which we see in diabetic ketoacidosis DKA. In DKA, acedo
- 11:01Speaker 2: acetate levels sore and the Jaffa method reads it as creatinine.
- 11:05Speaker 2: This gives you a falsely elevated creatinine result. We saw
- 11:08Speaker 2: a case report where this skewed the bun creatinine ratio
- 11:12Speaker 2: way down to five point six, which is misleading in DKA.
- 11:15Speaker 1: So if you suspect DKA, the Jaffa method.
- 11:18Speaker 2: Is an ideal, not ideal at all. The enzymatic methods
- 11:21Speaker 2: for creatinine are much better in this situation. They're specific
- 11:24Speaker 2: for creatanine and aren't affected by acetoacetate, giving you a
- 11:27Speaker 2: much truer picture of kidney function, which is critical when
- 11:30Speaker 2: managing DKA.
- 11:31Speaker 1: That's a clear advantage. Now you mentioned a high risk
- 11:33Speaker 1: error earlier related to glucose testing.
- 11:35Speaker 2: AH. Yes, the GDH jash PQQ glucose method. This one
- 11:40Speaker 2: has unfortunately been linked to patient harm, including fatalities.
- 11:44Speaker 1: How does that happen?
- 11:45Speaker 2: Some point of care. Glucose meters use an enzyme called
- 11:47Speaker 2: glucose dehydrogense, specifically the type that uses PQQ as a cofactor.
- 11:53Speaker 2: The problem is this enzyme system isn't specific to glucose.
- 11:57Speaker 2: It also reacts with other sugars like maltose or other ychodextrin.
- 12:00Speaker 1: Where would patients encounter those.
- 12:03Speaker 2: Maltose is often present in intravenous immune globulin IVG preparations.
- 12:08Speaker 2: Echodectrin is used in some peritoneal dialysis solutions, So a
- 12:12Speaker 2: patient receiving IVOG or using that type of dialysis fluid
- 12:16Speaker 2: might get a blood glucose check with one of these
- 12:18Speaker 2: meters and it reads falsely, sometimes dangerously high because it's
- 12:23Speaker 2: detecting the maltose or icodextrin.
- 12:25Speaker 1: And clinicians might give insulin based on that.
- 12:27Speaker 2: False high exactly, and there have been tragic cases where
- 12:30Speaker 2: unnecessary large doses of insulin were given based on these
- 12:34Speaker 2: erroneous readings, leading to severe hypoglycemia and death. The FDA
- 12:38Speaker 2: has issued multiple warnings about this specific technology.
- 12:41Speaker 1: That is terrifying. It really drives home why understanding the
- 12:44Speaker 1: method being used is so important, not just the result.
- 12:47Speaker 2: Absolutely crucial, especially for pharmacists involved in managing these patients.
- 12:50Speaker 1: Okay, let's talk therapeutic drug monitoring TDM. Useful for drugs
- 12:55Speaker 1: with narrow safety windows, right, but often done with immunoassays,
- 12:59Speaker 1: which have their own interference problems.
- 13:01Speaker 2: That's right. TDM is invaluable for optimizing dosing for certain drugs,
- 13:05Speaker 2: but the immunoassays commonly used, while fast and automated, are susceptible.
- 13:10Speaker 2: First major issue cross reactivity, meaning the antibody used in
- 13:15Speaker 2: the assay might bind not just to the target drug,
- 13:17Speaker 2: but also to structurally similar compounds, maybe other drugs the
- 13:20Speaker 2: patient is taking, or even metabolites of the target drug.
- 13:24Speaker 2: A good example is immunoassays for tricyclic antidepressants. They often
- 13:28Speaker 2: react with several different TCAs and their metabolites. Great for
- 13:32Speaker 2: a quick screen to see if something is there, but
- 13:34Speaker 2: not precise enough for monitoring a specific drug level.
- 13:37Speaker 1: Okay, cross reactivity. What else?
- 13:39Speaker 2: Second is a weird phenomenon called the high dose hook effect.
- 13:43Speaker 2: This happens when the concentration of the drug or analyte
- 13:46Speaker 2: is extremely high, so.
- 13:47Speaker 1: You'd expect a really high result.
- 13:49Speaker 2: You would, but instead the assay gets overwhelmed and you
- 13:52Speaker 2: get a falsely low or even normal result. It hooks down.
- 13:56Speaker 2: We sometimes see this with tumor markers like prolactin in
- 13:59Speaker 2: patients with massive pituitary tumors prolactinomas.
- 14:02Speaker 1: So how do you deal with that?
- 14:03Speaker 2: The lab technician needs to suspect it based on the
- 14:06Speaker 2: clinical picture, then dilute the samples significantly and rerun the test.
- 14:11Speaker 2: The dilution brings the concentration back into the assay's working range,
- 14:14Speaker 2: revealing the true very high.
- 14:16Speaker 1: Level lever and the third aminoassay issue.
- 14:20Speaker 2: Endogenous antibodies. These are antibodies naturally present in the patient's
- 14:24Speaker 2: own blood that interfere with the assay. They can be
- 14:27Speaker 2: heterophilic antibodies, which are nonspecific or specific auto antibodies. For example,
- 14:33Speaker 2: heterophilic antibodies can sometimes interfere with tachrolamus assays, or autoantibodies
- 14:38Speaker 2: combined to prolactin, creating macroprolactinemia, which gives a high prolactin
- 14:42Speaker 2: reading but isn't biologically active.
- 14:45Speaker 1: Can you fix that interference?
- 14:46Speaker 2: Sometimes? Treating the patient's sample with polyethylene glycol or PEG
- 14:51Speaker 2: can often precipitate out these interfering antibody complexes, allowing for
- 14:55Speaker 2: a more accurate measurement.
- 14:56Speaker 1: Okay, so imminoassays are fast but need careful interpretation. This
- 15:01Speaker 1: sounds similar to drug of abuse testing screening versus confirmation.
- 15:05Speaker 2: Very similar principle. The initial screening tests for drugs of
- 15:09Speaker 2: abuse are typically amino assays. They're fast and good for
- 15:12Speaker 2: ruling things out, but they suffer from cross reactivity leading
- 15:16Speaker 2: to false positives. Examples oh plenty. Certain quinn alone antibiotics
- 15:21Speaker 2: might trigger a positive on an opiate screen. Common things
- 15:24Speaker 2: like ibuprofen or the cof suppressant dextromethorphin have been known
- 15:28Speaker 2: to cross react with PCP assays. That's why any positive screen,
- 15:32Speaker 2: especially in illegal or workplace context, must be confirmed using
- 15:35Speaker 2: a much more specific method like mass spectrometry GCMs or LCMSMS.
- 15:41Speaker 2: Those methods identify the exact molecule.
- 15:43Speaker 1: Screening is suggestive, conformation is definitive. Got it. Let's touch
- 15:47Speaker 1: on one more analytical challenge. Lactate right.
- 15:50Speaker 2: Lactate measurement is crucial in critical care, but again the
- 15:52Speaker 2: method matters. Some analyzers, particularly certain blood gas machines, use
- 15:57Speaker 2: an L lactate oxidase method, and the problem is that
- 16:00Speaker 2: method is susceptible to positive interference from metabolites of ethylene glycol,
- 16:05Speaker 2: the main component of antifreeze, specifically glycylate and glyoxylate.
- 16:10Speaker 1: So if someone ingested antifreeze.
- 16:12Speaker 2: Their lactate reading on one of these machines could be
- 16:14Speaker 2: falsely elevated, potentially massively overestimated, maybe by as much as
- 16:18Speaker 2: sixty milllim due to this interference. If you suspect ethylene
- 16:22Speaker 2: glycol poisoning, you really need to use an LDH based
- 16:26Speaker 2: lactate method, which is much less prone to this specific
- 16:29Speaker 2: interference to get an accurate lactate level.
- 16:32Speaker 1: Another case where knowing the Assey method is critical for
- 16:35Speaker 1: correct diagnosis and treatment. Wow, we have covered so much
- 16:38Speaker 1: ground today, from just getting the patient ID right through
- 16:42Speaker 1: handling the sample, the timing the additives, patient factors like
- 16:45Speaker 1: age and diet, right down to the nay gritty chemistry
- 16:48Speaker 1: of the assays themselves. It is abundantly clear that getting
- 16:51Speaker 1: reliable clinical information from a lab test is way more
- 16:54Speaker 1: involved than just looking at a number.
- 16:57Speaker 2: It really is, and that's the core message for professionals
- 17:00Speaker 2: imply ordering more tests isn't better, It actually just increases
- 17:03Speaker 2: the chances for error. Somewhere along that complex chain, The
- 17:06Speaker 2: most effective way to improve the use of lab testing
- 17:09Speaker 2: to minimize errors and misinterpretation is through ongoing education, continuously
- 17:15Speaker 2: reinforcing awareness of all these factors, the pre analytical variables,
- 17:18Speaker 2: biological variation, the limitations of the assays. That's key.
- 17:23Speaker 1: So to help reinforce some of this, especially for our
- 17:25Speaker 1: listeners with a pharmacology focus, let's wrap up with a
- 17:28Speaker 1: practical thinking exercise.
- 17:29Speaker 2: Sounds good, okay. Imagine the scenario. You're reviewing labs for
- 17:33Speaker 2: a seventy five year old patient. Part of the panel
- 17:36Speaker 2: is a creatin nine level, and it comes back at
- 17:38Speaker 2: point nine miligdl that falls right within the typical normal
- 17:42Speaker 2: reference range, say zero point six to one point two miligedal. However,
- 17:46Speaker 2: you also know this patient is quite frail and has
- 17:47Speaker 2: significant circopenia that's reduced muscle mass. The question is why
- 17:52Speaker 2: should you, as the practitioner be cautious about using that
- 17:55Speaker 2: normal plasma creatinine value by itself to judge her true
- 17:59Speaker 2: kidney function, her or creating clearance. What's the underlying physiological
- 18:04Speaker 2: reason for that.
- 18:05Speaker 1: Caution right, Think back to what we discussed about age
- 18:07Speaker 1: and muscle mass. The answer, as we covered is that
- 18:11Speaker 1: while she likely has that age related decline in actual
- 18:14Speaker 1: GFR maybe thirty forty percent. Her circopenia means she's producing
- 18:18Speaker 1: less creating from muscle turnover, so the lower production masks
- 18:23Speaker 1: the lower clearance, keeping her serum level deceptively within the
- 18:26Speaker 1: normal range. Relying on it alone would likely lead you
- 18:30Speaker 1: to overestimate her actual kidney function exactly.
- 18:32Speaker 2: You always need to factor in that muscle mass context,
- 18:34Speaker 2: especially when making drug dosing decisions for renally cleared medications
- 18:38Speaker 2: in the elderly. It's a vital adjustment to.
- 18:40Speaker 1: Make the perfect example of integrating patient context with lab data.
- 18:43Speaker 2: Absolutely well, thanks for diving deep with us today.
- 18:46Speaker 1: Indeed, until the next deep dive, stay curious and always
- 18:49Speaker 1: question your data.