- 0:00Speaker 1: Welcome to the deep Dive. Today. We're tackling a big one,
- 0:03Speaker 1: analytical chemistry for technicians. We're aiming to condense, you know,
- 0:07Speaker 1: thirty six years of teaching experience packed into this fourth edition.
- 0:11Speaker 2: Yeah, it's quite the resource. John Kenkell really designed it
- 0:13Speaker 2: as a practical guide for anyone working in.
- 0:15Speaker 1: A lab, right, whether you're just starting out, maybe teaching yourself,
- 0:19Speaker 1: or even managing a pharmaceutical lab setup exactly.
- 0:22Speaker 2: It covers the whole spectrum really, from basic safety write
- 0:25Speaker 2: up to advanced instruments. Our goal here is to sort
- 0:28Speaker 2: of pull out the core framework, focusing on precision and
- 0:31Speaker 2: how you actually use this stuff.
- 0:32Speaker 1: And I noticed this edition really leans into the practical side,
- 0:35Speaker 1: doesn't it. It seems designed to get technicians thinking, not
- 0:39Speaker 1: just doing. What's new there?
- 0:41Speaker 2: Oh, definitely for visual learners. They're over over one hundred
- 0:44Speaker 2: and fifty new photos, lots of rework drawings, helps clarify
- 0:48Speaker 2: techniques setups.
- 0:50Speaker 1: Makes sense.
- 0:50Speaker 2: But the big thing I think is the lab experiments.
- 0:53Speaker 2: Thirteen new ones and crucially nine of them are design
- 0:56Speaker 2: in experiment exercises.
- 0:58Speaker 1: Ah, that's interesting, So it pushes you beyond just following
- 1:01Speaker 1: steps precisely.
- 1:02Speaker 2: You have to think about the methodology, structure it yourself.
- 1:05Speaker 2: And speaking of methods, the instrumental analysis section got a
- 1:08Speaker 2: major upgrade too.
- 1:09Speaker 1: Yeah I saw that MasSpec.
- 1:11Speaker 2: Yep, whole new chapter on mass spectrometry covers the basics
- 1:14Speaker 2: you know, generating ions, separating them, and then the really
- 1:17Speaker 2: important couple techniques like GCMs, LCMS, even ICPMS. It really
- 1:23Speaker 2: brings it up to date with modern lab practice.
- 1:26Speaker 1: Okay, great, let's dive in. Then, starting right at the beginning,
- 1:28Speaker 1: before any analysis, there's the lab itself. Safety First, what
- 1:33Speaker 1: are the absolute must dos CAN goal lays out?
- 1:36Speaker 2: Well, the fundamentals are quite straightforward but absolutely critical. First off,
- 1:40Speaker 2: safety glasses yeah, always for everyone in the lab, no exceptions,
- 1:44Speaker 2: non negotiable, unnegotiable. Second, fune hoods are essential anytime you're
- 1:48Speaker 2: working with hazardous or volatile chemicals. Got to vent those
- 1:51Speaker 2: fumes safely right. And finally, waste disposal. You must follow
- 1:55Speaker 2: the analyst's instructions to the letter. Getting that wrong can
- 1:58Speaker 2: cause major contamination or war ver safety hazards.
- 2:01Speaker 1: Okay, so safety covered. The next big hurdle is always
- 2:05Speaker 1: dealing with uncertainty right, getting results you can actually trust.
- 2:09Speaker 1: The book talks about two main types of error.
- 2:11Speaker 2: That's right, two categories. First, you've got determinate errors, sometimes
- 2:15Speaker 2: called systematic errors. These are the ones you can usually identify,
- 2:18Speaker 2: things like a miscalibrated balance, maybe some contamination using the
- 2:23Speaker 2: wrong procedure.
- 2:24Speaker 1: Things you can potentially fix or account for exactly.
- 2:28Speaker 2: If you find a determinate error, you generally have to
- 2:30Speaker 2: reject that result or maybe recalculate if possible.
- 2:33Speaker 1: Okay, so those are the avoidable errors. What about the
- 2:36Speaker 1: other kind, the ones you can't easily pin down.
- 2:38Speaker 2: Those are indeterminate errors or random errors. They're just inherent
- 2:41Speaker 2: in any measurement process, sort of the background noise.
- 2:44Speaker 1: The limits of the equipment, maybe.
- 2:46Speaker 2: Pretty much is why, even if you do everything perfectly,
- 2:49Speaker 2: repeat measurements will still vary slightly once you've eliminated the
- 2:53Speaker 2: systematic stuff. The consistency of your results the precision that
- 2:57Speaker 2: tells you a lot about your accuracy.
- 3:00Speaker 1: We need ways to measure that precision to put a
- 3:02Speaker 1: number on how good our data is. What's the key
- 3:05Speaker 1: metric technicians use?
- 3:06Speaker 2: The main one is the relative standard deviation or RSD.
- 3:09Speaker 2: It's basically the standard deviation divided by the mean, usually
- 3:12Speaker 2: shown as a.
- 3:13Speaker 1: Percentage lower is better.
- 3:14Speaker 2: I assume absolutely A smaller RSD means your data points
- 3:18Speaker 2: are clustered tightly together. You know, for a lot of
- 3:20Speaker 2: QC work, like validating an HPLC method, people often look
- 3:24Speaker 2: for an RSD below SA zero point five percent. That's
- 3:27Speaker 2: considered pretty favorable.
- 3:28Speaker 1: Okay, now what about that single data point that looks
- 3:32Speaker 1: off the outlier? We can't just throw it out because
- 3:35Speaker 1: we don't like it. The book mentions the Q test.
- 3:37Speaker 2: Right, The Q test gives you an objective statistical reason
- 3:41Speaker 2: to potentially reject an outlier. You don't just eyeball it.
- 3:45Speaker 1: So how does it work in the simple terms.
- 3:46Speaker 2: Well, you calculate a Q value. You look at the
- 3:48Speaker 2: difference between your suspect value and the next closest value
- 3:51Speaker 2: that's the gap. Then you divide that by the total
- 3:53Speaker 2: spread of all your data points the range highest minus lowest.
- 3:56Speaker 2: You compare your calculated queue to a critical Q value
- 4:00Speaker 2: from a table based on how many measurements you took.
- 4:03Speaker 2: If your queue is bigger than the critical value, then
- 4:06Speaker 2: you have statistical grounds to reject that point. For instance,
- 4:09Speaker 2: with six measurements, the critical que is zero point five six.
- 4:13Speaker 1: Got it? A systematic way to handle flyers. So Q
- 4:17Speaker 1: test helps with the final number, but that number is
- 4:20Speaker 1: useless if the sample itself was bad from the start.
- 4:23Speaker 1: How crucial is sample handling?
- 4:24Speaker 2: Oh, it's absolutely fundamental. Your analysis is only ever as
- 4:27Speaker 2: good as the sample you start with. Think about environmental
- 4:30Speaker 2: water testing for example. Okay, if you're analyzing for metals
- 4:34Speaker 2: like iron, you have to preserve that sample immediately, usually
- 4:37Speaker 2: by adding nitric acid to get the pH below two.
- 4:40Speaker 1: Why what does that do?
- 4:41Speaker 2: It stops the metals from oxidizing and precipitating out as solids. Ye.
- 4:45Speaker 2: If they precipitate, you're not measuring what was actually dissolved
- 4:48Speaker 2: in the water.
- 4:49Speaker 1: Makes sense, And I guess different analytes need different preservation exactly.
- 4:54Speaker 2: If you're looking for phosphase, for instance, you generally avoid
- 4:57Speaker 2: plastic containers unless you freeze the sample, and critically never
- 5:01Speaker 2: wash the glassware with standard detergents. They're loaded with phosphates
- 5:05Speaker 2: instant contamination, right right?
- 5:08Speaker 1: Okay, So preserving the sample is one thing, What about
- 5:10Speaker 1: actually getting it dissolved for analysis? Some samples must be
- 5:14Speaker 1: really tough to break down.
- 5:16Speaker 2: They can be. The book goes through specific acid chemistry
- 5:20Speaker 2: like hydrochloric acid HCl is good for dissolving things like
- 5:23Speaker 2: iron or zinc, metal so oxides, carbonates, standard stuff. Yeah,
- 5:27Speaker 2: but for more resistant metals like copper or silver, you
- 5:30Speaker 2: need something stronger, an oxidizer like nitric acid H and
- 5:34Speaker 2: O three.
- 5:34Speaker 1: And then there's the really heavy hitter Aquareresia. Sounds intense,
- 5:38Speaker 1: it is.
- 5:39Speaker 2: It's a mix one part concentrated nitric, three parts concentrated EACHCL.
- 5:42Speaker 2: It's called royal water because it can dissolve noble metals
- 5:45Speaker 2: like gold and platinum that resist other acids.
- 5:48Speaker 1: Wow, okay, and what if even that doesn't work.
- 5:51Speaker 2: For the absolute toughest samples. There's fusion. This involves mixing
- 5:55Speaker 2: your sample with an inorganic salt a flux and heating
- 5:58Speaker 2: it like crazy from three hundred to a thousand degrees celsius.
- 6:02Speaker 2: The molten salt chemically breaks down the sample matrix, making
- 6:06Speaker 2: it soluble.
- 6:07Speaker 1: Okay, so several tools in the arsenal for dissolution. Let's
- 6:10Speaker 1: shift to a classical technique, gravimetric analysis. It seems simple,
- 6:15Speaker 1: just weighing things, but I suspect there's more to it there.
- 6:18Speaker 2: Definitely is. It's all about accurate weighing. Yes, But the
- 6:21Speaker 2: core steps are prepare your sample. Then somehow separate the
- 6:25Speaker 2: analyte you're interested in. That might be physical separation or
- 6:29Speaker 2: chemically changing it into something solid you can.
- 6:31Speaker 1: Isolate, like precipitating it exactly.
- 6:33Speaker 2: Then the final step is carefully weighing that isolated substance.
- 6:37Speaker 2: Technicians use specific tools like weighing bottles and techniques like
- 6:41Speaker 2: weighing by difference to minimize errors.
- 6:43Speaker 1: And you don't just report the weight of the precipitate, right,
- 6:45Speaker 1: You have to relate it back.
- 6:46Speaker 2: Correct You use something called a graphometric factor. It's a
- 6:49Speaker 2: stoichiometric ratio that lets you convert the weight of what
- 6:54Speaker 2: you actually weighe say, barium sulfate back to the weight
- 6:57Speaker 2: of the thing you originally wanted to measure, like sodium
- 7:00Speaker 2: sulfate in the initial sample.
- 7:01Speaker 1: Got it, Okay, Let's move to volumetric methods titrations. The
- 7:05Speaker 1: book brings up molarity versus normality. Normality can be tricky.
- 7:09Speaker 2: It often trips people up because, unlike molarity, which is
- 7:13Speaker 2: just moles per lead, normality n is equivalents per led,
- 7:18Speaker 2: and what constitutes an equivalent depends entirely on the specific
- 7:22Speaker 2: chemical reaction you're doing.
- 7:23Speaker 1: You can give an example.
- 7:24Speaker 2: Sure, take sulfuric acid Textestal forty four ye. If it
- 7:27Speaker 2: reacts in a titration where it gives up both its
- 7:30Speaker 2: hydrogen ions, then one mole of sulfuric acid provides two
- 7:33Speaker 2: equivalents of acid. So a one molar solution would be
- 7:37Speaker 2: two normal two n. But if it's in a reaction
- 7:39Speaker 2: where it only gives up one hydrogen, then one mole
- 7:42Speaker 2: is just one equivalent and one molar is one normal.
- 7:44Speaker 2: So you have to understand the stoiccheometry right.
- 7:46Speaker 1: It forces you to think about the actual chemistry happening.
- 7:49Speaker 2: Now.
- 7:49Speaker 1: With titrations, the concentration of your titrant solution is critical.
- 7:54Speaker 1: How do we know that concentration is accurate and reliable?
- 7:57Speaker 2: That comes down to standards we often standardize. Are working
- 8:00Speaker 2: titrant solutions against primary standards. These are chemicals known to
- 8:05Speaker 2: be exceptionally pure and stable.
- 8:07Speaker 1: Okay, But where do those primary standards get their authority?
- 8:10Speaker 1: So to speak? How do we get consistency across labs?
- 8:13Speaker 2: That trace ability goes back to national standards bodies. In
- 8:17Speaker 2: the US, it's the National Institute for Standardization and Technology
- 8:20Speaker 2: or NIST. They provide the Ultimate Standard Reference Materials SRMs,
- 8:25Speaker 2: the gold standard pretty much. Chemical suppliers then use these
- 8:28Speaker 2: SRMs to produce their own certified Reference materials CRMs that
- 8:32Speaker 2: labs buy. This whole chain ensures that a result measured
- 8:35Speaker 2: in one lab is comparable to a result measured anywhere
- 8:38Speaker 2: else in the world. It's vital for quality control trade.
- 8:42Speaker 1: Everything makes sense. Let's look at a practical titration example.
- 8:45Speaker 1: The book uses edta for water hardness. How does that work?
- 8:49Speaker 2: Water hardness is usually caused by calcium and magnesium ions.
- 8:54Speaker 2: Edta is a chalating agent that binds very strongly to
- 8:57Speaker 2: these ions, typically in one to one ratio. So you
- 9:00Speaker 2: titrate your water sample with a standardized edta solution. At
- 9:04Speaker 2: the endpoint, you know the moles of edta you added,
- 9:07Speaker 2: since it's one to one, that equals the moles of
- 9:10Speaker 2: hardness ions expressed as tex scalo three.
- 9:12Speaker 1: And how do you get to ppm tex scalo three three.
- 9:15Speaker 2: You take the moles of dta multiplied by the formula
- 9:18Speaker 2: weight of calcium carbonate, which is about one hundred geomole
- 9:21Speaker 2: that gives you grams perleter, then multiple by the thousand
- 9:23Speaker 2: to get milligrams per leter, which is the same as
- 9:26Speaker 2: parts per million ppm neat.
- 9:28Speaker 1: What about situations where you can't titrate the analyte directly.
- 9:32Speaker 1: The book mentions iodometry for oxidizing agents.
- 9:35Speaker 2: Yeah, iodometry is a classic indirect titration. It's often used
- 9:38Speaker 2: for things like measuring residual chlorine and treated wastewater. You
- 9:42Speaker 2: don't titrate the chlorine itself, well do you do? Instead?
- 9:44Speaker 2: You add an excess of potassium iodide to the sample.
- 9:47Speaker 2: The chlorine or other oxidizing agent reacts with the iodide,
- 9:51Speaker 2: oxidizing it to produce molecular iodine textalites.
- 9:54Speaker 1: Ah, so you generate iodine in proportion to the chlorine exactly.
- 9:58Speaker 2: Then you immediately titrate the liberated iodine with a standardized
- 10:02Speaker 2: solution of sodium thiosulfate. It's a clever way to measure
- 10:06Speaker 2: something reactive indirectly.
- 10:08Speaker 1: Very clever. Okay, let's shift gears into the instrumental world. Now.
- 10:11Speaker 1: Chromatography is huge. The book breaks it down by mechanism.
- 10:15Speaker 2: Yes, it simplifies it into four main types based on
- 10:18Speaker 2: how the separation actually happens. What are they First is
- 10:21Speaker 2: partition chromatography Separation is based on how well the analyte
- 10:25Speaker 2: dissolves or partitions between the mobile phase and a liquid
- 10:29Speaker 2: stationary phase coded on a support.
- 10:31Speaker 1: Like dissolves like basically.
- 10:33Speaker 2: Kind of Yeah. Then there's absorption chromatography like LS or GSE.
- 10:37Speaker 2: Here separation depends on how strongly components absorb onto the
- 10:41Speaker 2: surface of a solid stationary fise.
- 10:43Speaker 1: Okay, two more.
- 10:44Speaker 2: Third is ion exchange chromatography IEC. This uses a stationary
- 10:49Speaker 2: phase with fixed charge sites to separate ions based on
- 10:52Speaker 2: their charge. And fourth is size exclusion chromatography SEC, which
- 10:56Speaker 2: separates molecules based purely on their physical size. Bigger molecules
- 10:59Speaker 2: usually come out first because they can't get into the
- 11:01Speaker 2: small pores of the stationary phase.
- 11:03Speaker 1: Right, they take a more direct path. Now, when you
- 11:05Speaker 1: run something like GC or HPLC, you get that chromatogram,
- 11:09Speaker 1: the series of peaks. What are the key things a
- 11:12Speaker 1: technician needs to read from that?
- 11:13Speaker 2: Two main things. First, the retention time. Yeah, that's the
- 11:17Speaker 2: time it takes from injection until the peak maximum comes out.
- 11:20Speaker 2: It helps you identify what the compound probably is by comparing.
- 11:23Speaker 1: It to standard qualitative info.
- 11:25Speaker 2: Right. The second is resolution. This measures how well separated
- 11:29Speaker 2: adjacent peaks are. You want good separation to quantify accurately.
- 11:32Speaker 2: A resolution value of one point five or more usually
- 11:35Speaker 2: means the peaks are baseline separated, which is ideal. Got it?
- 11:39Speaker 1: And the big new instrument chapter is on mass spectrometry.
- 11:43Speaker 1: What's the fundamental idea behind mstry.
- 11:45Speaker 2: The core principle is you take your analyte molecules, turn
- 11:48Speaker 2: them into ions somehow, and then you separate those ions
- 11:51Speaker 2: based on their mass to charge ratio, usually written as
- 11:54Speaker 2: mz all.
- 11:55Speaker 1: How does separating by mass help?
- 11:57Speaker 2: Because each molecule fragments and ionize is in a characteristic way.
- 12:01Speaker 2: If the resulting pattern of MZO values acts like a
- 12:04Speaker 2: unique fingerprint, it allows for very confident identification.
- 12:07Speaker 1: So moving beyond just retention time, how does coupling it
- 12:11Speaker 1: with GC or lc change things for the technician?
- 12:14Speaker 2: It's a hugely been certainty. With GCMs or lcms. The
- 12:18Speaker 2: mass spectrometer acts as a highly specific detector after the
- 12:21Speaker 2: chromatography separation. So if two things happen to colude come
- 12:24Speaker 2: out at the same time, which happens, oh yeah, A
- 12:26Speaker 2: simple UV detector might just show one big blob, but
- 12:29Speaker 2: the MS can often distinguish them because they'll have different
- 12:32Speaker 2: masses or fragmentation patterns. It adds that crucial layer of
- 12:35Speaker 2: identification and ICPMS. That sounds different it is. ICPMS uses
- 12:40Speaker 2: an inductively coupled plasma that's an extremely hot argon plasma
- 12:44Speaker 2: as the ion source. It completely atomizes and ionizes the sample.
- 12:48Speaker 2: It's primarily used for ultra sensitive elemental analysis, detecting metals
- 12:52Speaker 2: and non metals down to very low levels.
- 12:54Speaker 1: Okay, powerful stuff. Let's touch on spectroscopy and electric chemistry
- 12:58Speaker 1: to round things out. The book distinguishes molecular versus atomic spectroscopy.
- 13:03Speaker 1: What's the key visual difference in the output?
- 13:06Speaker 2: It's about the spectrum you see. Molecular spectroscopy, like uvv's
- 13:09Speaker 2: absorption involves transitions between electronic and vibrational energy levels in molecules.
- 13:14Speaker 2: This leads to broad continuous absorption bands. Think of the
- 13:18Speaker 2: smooth absorption curve for a colored solution like blue copper sulfate.
- 13:22Speaker 1: Okay, broad bands.
- 13:23Speaker 2: Whereas atomic spectroscopy, like atomic absorption AA or atomic mission AE,
- 13:28Speaker 2: deals with atoms in a gaseous state. They only have
- 13:30Speaker 2: specific electronic transitions available, no vibration or rotation, so their
- 13:34Speaker 2: spectra consists of sharp, distinct lines at very specific.
- 13:37Speaker 1: Wavelengths lines versus bands, got it, And infrared IR spectroscopy
- 13:41Speaker 1: has that weird requirement for sample cells, right, something about
- 13:44Speaker 1: salt plates.
- 13:45Speaker 2: Yeah, that's a classic practical point. IR cells. The windows
- 13:48Speaker 2: that bean passes through have to be made of materials
- 13:51Speaker 2: that don't absorb ir light themselves. Common choices are inorganic
- 13:55Speaker 2: salts like sodium chloride and ACL or potassium bromide.
- 13:59Speaker 1: Kbry not just use glass or plastic cuvettes like in uvvs.
- 14:03Speaker 2: Because glass plastic water. But basically anything with covalent bonds
- 14:07Speaker 2: does absorb ir radiation quite strongly due to molecular vibrations.
- 14:11Speaker 2: If you use a glass cell, its own absorption would
- 14:14Speaker 2: swamp the spectrum of your sample. Salt crystals are ionic,
- 14:17Speaker 2: they don't have those molecular vibrations in the same way.
- 14:19Speaker 1: Ah, so the cell material itself would interfere makes sense, okay. Lastly, electrochemistry,
- 14:24Speaker 1: what are the main techniques covered?
- 14:26Speaker 2: The book focuses on two core areas. First is potentiometry.
- 14:30Speaker 2: This involves measuring the electrical potential the voltage difference between
- 14:33Speaker 2: two electrodes dipped in the solution.
- 14:35Speaker 1: What electrodes?
- 14:36Speaker 2: You have? An indicator electrode whose potential responds to the
- 14:39Speaker 2: analyte concentration, like a pH glass electrode or an ion
- 14:43Speaker 2: selective electrode IC for fluoride or something. And then you
- 14:46Speaker 2: have a reference electrode which maintains a constant potential like
- 14:49Speaker 2: the silver silver chloride electrode. pH Meters work this way,
- 14:53Speaker 2: as do potentiometric titrations.
- 14:55Speaker 1: Okay, and the other main electrochemical technique that.
- 14:58Speaker 2: Would be the Carl Fischer ty tree. This is a
- 15:01Speaker 2: highly specific and sensitive method just for determining water content,
- 15:05Speaker 2: whether in solids or liquids.
- 15:06Speaker 1: How does it work? Is it like a regular titration.
- 15:09Speaker 2: It is a titration, but the chemistry is specific for water.
- 15:12Speaker 2: It uses ionine in a reaction. The end point when
- 15:15Speaker 2: all the water is consumed is usually detected electrochemically, either
- 15:19Speaker 2: by a sudden changing current between two platinum electrodes ambimetrically
- 15:23Speaker 2: or a change in potential tensiometrically.
- 15:26Speaker 1: And how is the titrant added.
- 15:28Speaker 2: It can be added from a buret like a normal titration, volumetrically,
- 15:31Speaker 2: or for very small amounts of water, the iodine can
- 15:34Speaker 2: actually be generated electrochemically right in the reaction vessel coolometrically
- 15:38Speaker 2: very precise.
- 15:39Speaker 1: Wow. Okay, we've covered a lot of ground, from wearing
- 15:42Speaker 1: your safety glasses to the intricacies of coolometric Carl Fisher
- 15:46Speaker 1: and ICPMS. This book really seems comprehensive for a technician.
- 15:50Speaker 2: It truly aims to be. It provides not just the theory,
- 15:53Speaker 2: but the practical know how needed for applying these techniques reliably,
- 15:57Speaker 2: whether you're checking environmental samples or ensuring pharmaceutical quality. It
- 16:01Speaker 2: really emphasizes accuracy through understanding the methods, the potential errors,
- 16:05Speaker 2: and the standards.
- 16:07Speaker 1: Absolutely so to help everyone listening consolidate one of those
- 16:10Speaker 1: key ideas dealing with beta quality, let's end with a
- 16:13Speaker 1: little exercise based on the Q test we discussed.
- 16:15Speaker 2: Sounds good, Okay, here's the scenario for you. Imagine you've
- 16:19Speaker 2: run an analysis six times so N six. You're looking
- 16:22Speaker 2: at your results and one value looks suspiciously different from
- 16:24Speaker 2: the others. The critical que value for rejecting an outlier
- 16:28Speaker 2: when N six is Broyo five six. Briefly, what are
- 16:31Speaker 2: the general steps you'd take to decide statistically if you
- 16:34Speaker 2: should exclude that suspicious value before calculating your average and
- 16:37Speaker 2: remember to define the two key terms you need for
- 16:40Speaker 2: the calculation gap and range.
- 16:43Speaker 1: Great question something to mull over that brings us to
- 16:46Speaker 1: the end of this deep dive into analytical chemistry essentials.
- 16:49Speaker 1: Thanks for joining us, and we'll catch you on the
- 16:51Speaker 1: next one.