Latest / Civil Engineering Made Simple / Hollow Structural Section Connections
Transcript
- 0:00Speaker 1: Okay, let's unpack this. We are diving deep into some
- 0:04Speaker 1: very specific but absolutely essential structural engineering knowledge.
- 0:08Speaker 2: Today we are we're looking at how to connect hollow
- 0:10Speaker 2: structural sections or HSS. Our main source is the AISC
- 0:15Speaker 2: Design Guide twenty four by Packer, Sherman and letche.
- 0:18Speaker 1: If For anyone who's not deep in the field. HSS
- 0:21Speaker 1: is everywhere in modern construction. It's popular because it's efficient,
- 0:25Speaker 1: it's light, and frankly, it just looks good.
- 0:28Speaker 2: Architects love it. You see it in these big exposed
- 0:30Speaker 2: trust structures like at the Rock and Roll Hall of
- 0:32Speaker 2: Fame or parts of the Upperland Hotel.
- 0:35Speaker 1: They do look great, and they're structurally very efficient, you know,
- 0:39Speaker 1: less surface area, less weight than a comparable open section.
- 0:42Speaker 1: But and this is the big butt, the connections, the connections.
- 0:45Speaker 1: If you've ever detailed an HSS joint, you know exactly
- 0:48Speaker 1: where the headache is.
- 0:48Speaker 2: Yeah, the member itself is straightforward, it's the joint that's tricky.
- 0:52Speaker 2: The way an HSS connection behaves locally is just fundamentally
- 0:55Speaker 2: different from say a standard wide flange beam.
- 0:58Speaker 1: And that's our mission today. We want to give you
- 1:01Speaker 1: a clear technical roadmap through those critical design limits. And
- 1:05Speaker 1: best practices for HSS connection, turning that.
- 1:08Speaker 2: Dense guide into something you can really use exactly.
- 1:12Speaker 1: So let's start with the basics. What's the framework we're
- 1:14Speaker 1: operating in.
- 1:15Speaker 2: Okay, So the whole guide is built on the two
- 1:17Speaker 2: thousand and five AISC Specification for Structural Steel Buildings. Specifically,
- 1:22Speaker 2: it's all about Chapter K.
- 1:24Speaker 1: Chapter K, right, that's the section on forces and branch
- 1:27Speaker 1: members framing into a main member.
- 1:29Speaker 2: That's the one and for students or young professionals listening,
- 1:33Speaker 2: the guide covers both LRFD and ASD solutions.
- 1:36Speaker 1: Which is really helpful. You can follow along no matter
- 1:38Speaker 1: which design philosophy you're using.
- 1:40Speaker 2: Exactly. The core strength equations for the connection limits are
- 1:43Speaker 2: the same. You're just adjusting how you factor the loads
- 1:46Speaker 2: and resistances. It's got both paths covered.
- 1:49Speaker 1: Okay, let's get into the fine print, the stuff that
- 1:51Speaker 1: can really trip you up if you're new to HSS.
- 1:54Speaker 2: Right, there are a few big ones first, and this
- 1:57Speaker 2: is critical. This guide is for non seismic apple cations only, so.
- 2:01Speaker 1: If you're in a high size MiG zone, this isn't
- 2:04Speaker 1: your starting.
- 2:04Speaker 2: Point, absolutely not. You need to jump to much more
- 2:07Speaker 2: advanced specifications. The energy dissipation requirements totally change the game
- 2:12Speaker 2: for connection design. Okay, what else, Well, there are material
- 2:15Speaker 2: concerns like notch toughness, especially if you're building in a
- 2:19Speaker 2: cold climate, and galvanizing these closed shapes can be a
- 2:22Speaker 2: whole process. But the biggest threat, the one that really
- 2:25Speaker 2: demands careful detailing, is internal corrosion.
- 2:29Speaker 1: It sounds insidious, like a long term problem waiting to happen.
- 2:33Speaker 2: It is. Because HSS members are closed, water can get
- 2:37Speaker 2: trapped inside, maybe from a leak, maybe just condensation from
- 2:41Speaker 2: temperature changes. And if that water sits there, you get.
- 2:44Speaker 1: Rust and you lose wall thickness over time.
- 2:47Speaker 2: That's problem number one. Problem number two is a lot
- 2:50Speaker 2: more dramatic go on. The guide makes a big point
- 2:53Speaker 2: about this. If that water gets trapped in there and
- 2:55Speaker 2: then it freezes, well, you know what happens when water
- 2:58Speaker 2: turns to ice. It expands, right, and that expansion can
- 3:01Speaker 2: generate enough pressure to literally burst the HSS from the
- 3:05Speaker 2: inside out. We're not just fighting structural loads, we're fighting
- 3:09Speaker 2: basic physics.
- 3:10Speaker 1: Wow. Okay, so ceiling inventing isn't just an afterthought. It's
- 3:14Speaker 1: fundamental to the integrity of the member.
- 3:16Speaker 2: It's paramount a good reminder that our job involves thinking
- 3:20Speaker 2: way beyond just static loads.
- 3:21Speaker 1: Okay, So with that in the back of our minds, Yeah,
- 3:25Speaker 1: how do we actually join these things together? Yeah, let's
- 3:27Speaker 1: talk methods. Welding seems like the obvious first.
- 3:30Speaker 2: Choice, it's the most common, and chapter two of the
- 3:33Speaker 2: guide breaks down the four main weld types, usually in
- 3:36Speaker 2: order of you know, preference and cost.
- 3:39Speaker 1: And at the top of that list, the most economical.
- 3:41Speaker 2: Is flay welds. They're simple, they're fast in the shop,
- 3:44Speaker 2: and they're easy to inspect.
- 3:45Speaker 1: And then it gets more complex.
- 3:46Speaker 2: Right, you move up to partial joint penetration or PJP
- 3:50Speaker 2: groove welds. Then you have things like flare bevel and
- 3:53Speaker 2: flair V groove welds, which you'd use for say, around
- 3:57Speaker 2: branch connecting to a flat face.
- 3:58Speaker 1: And at the very top most expensive option.
- 4:01Speaker 2: That would be the complete joint penetration or CJP groove weld.
- 4:06Speaker 2: Very time consuming, very expensive.
- 4:09Speaker 1: So why would an engineer ever choose a CJP weld
- 4:12Speaker 1: if a filet is so much cheaper and faster. What's
- 4:15Speaker 1: the trade off there?
- 4:16Speaker 2: It's all about performance under stress. A filet weld is
- 4:19Speaker 2: great for lower stress joints. But if you need to
- 4:22Speaker 2: develop the full strength of the member, or if you're
- 4:24Speaker 2: dealing with high localized strain or fatigue, a CJP weld
- 4:28Speaker 2: becomes mandatory.
- 4:29Speaker 1: So you're paying for confidence.
- 4:31Speaker 2: Essentially, you're paying for performance and confidence. It means more
- 4:34Speaker 2: prep time, more shop time, and way more inspection, usually
- 4:38Speaker 2: non destructive testing. But you know that connection is as
- 4:41Speaker 2: strong as the steal around it.
- 4:43Speaker 1: And when we're designing these welds, there are two main philosophies.
- 4:46Speaker 2: Right yeah, two ways to approach the calculation. The first
- 4:49Speaker 2: is super conservative. You just make the weld strong enough
- 4:52Speaker 2: to develop the full yield strength of the branch wall.
- 4:54Speaker 2: That's a safe upper limit.
- 4:56Speaker 1: But the second, more common way, the more.
- 4:58Speaker 2: Common approach, is to use what are called effective weld lengths,
- 5:01Speaker 2: and you just ensure you maintain the same effective weld
- 5:04Speaker 2: size all the way around the branch. It's more precise.
- 5:06Speaker 1: Okay, let's pivot. What about mechanical fasteners bolting Chapter three?
- 5:12Speaker 1: This brings up what the guide calls the access problem.
- 5:15Speaker 2: The access problem. Yeah, it's the fundamental issue with bolting HSS.
- 5:19Speaker 2: How do you tighten a nut on the inside of
- 5:21Speaker 2: a closed box?
- 5:22Speaker 1: Right? You can't reach in there.
- 5:23Speaker 2: So you have to get creative. The most common solution
- 5:26Speaker 2: is probably through bolting, where a single bolt goes all
- 5:29Speaker 2: the way through both walls of the HSS.
- 5:31Speaker 1: Which means you need access holes and you've got to
- 5:34Speaker 1: seal those holes up, which brings us right back to
- 5:36Speaker 1: the corrosion problem exactly.
- 5:38Speaker 2: Other options are things like threaded studs that are welded on,
- 5:42Speaker 2: or these very specialized blind bolts that can be installed
- 5:46Speaker 2: and torqued completely from one side.
- 5:48Speaker 1: So when you're using through bolts and they're in shear,
- 5:51Speaker 1: what are the failure modes we need to check for?
- 5:53Speaker 1: Is it different from a standard connection?
- 5:55Speaker 2: Some of it's the same. You still check for bolt
- 5:58Speaker 2: shear and block sheer reps and you're the end of
- 6:00Speaker 2: the member. But there's one huge distinction for HSS. Okay,
- 6:04Speaker 2: you don't use the standard bolt bearing equations. You have
- 6:07Speaker 2: to use pin bearing strength equation.
- 6:10Speaker 1: Pin bearing Okay, that's a detail that could easily be missed.
- 6:14Speaker 1: Why the change? What does that really mean?
- 6:17Speaker 2: It's all because the HSS wall is so flexible. A
- 6:20Speaker 2: standard bolt bearing equation assumes the bolt is pushing against
- 6:24Speaker 2: a nice rigid plate like the flange of a W beam.
- 6:27Speaker 1: But the HSS wall isn't rigid at all.
- 6:29Speaker 2: Not at all. It acts more like a thin sheet
- 6:31Speaker 2: of metal with a pin through it. It deforms locally.
- 6:35Speaker 2: The pin bearing equations are designed specifically to account for
- 6:38Speaker 2: that local bending and flexibility.
- 6:40Speaker 1: Got it. So you're designing for a flexible surface, not
- 6:42Speaker 1: a stiff plate. And if the bolts are intention pulling
- 6:45Speaker 1: away from the HSS, I'm guessing more checks.
- 6:47Speaker 2: Oh, absolutely, on top of the bolt's own capacity. You
- 6:50Speaker 2: have two HSS specific failures to check. First is just
- 6:53Speaker 2: pull out the bolt, literally ripping through the wall. The
- 6:55Speaker 2: second is distortion of the HSS wall. We call it plastification.
- 7:00Speaker 2: It's the face of the HSS yielding and deforming as
- 7:03Speaker 2: that concentrated tensile force tries to bend it outwards.
- 7:07Speaker 1: Which brings us to the real heart of HSS design philosophy. Right,
- 7:11Speaker 1: It's all about that flexible face.
- 7:13Speaker 2: This is it. This is the core concept from chapter six.
- 7:16Speaker 2: What's fascinating here is that, unlike a W shape where
- 7:19Speaker 2: the web gives you all this rigidity, with HSS, the
- 7:23Speaker 2: local strength of the connecting face is almost always the
- 7:26Speaker 2: limiting factor.
- 7:27Speaker 1: So the mental model is key. Don't think of it
- 7:29Speaker 1: as a rigid connection point. Think of it as a
- 7:31Speaker 1: flexible plate that's going.
- 7:32Speaker 2: To distort precisely. And that leads to the four principal
- 7:36Speaker 2: limit states for welded joints. The first one and by
- 7:39Speaker 2: far the most common, is cord or column wall plastification.
- 7:42Speaker 1: Okay, pay to picture that for us. What does that
- 7:45Speaker 1: failure look like?
- 7:45Speaker 2: Imagine the face of a rectangular HSS, like a drum
- 7:49Speaker 2: skin or a thin steel plate that's spanning between the
- 7:52Speaker 2: two side walls. When the branch pushes or pulls on it,
- 7:55Speaker 2: that plate just bends. You get these large permanent deformations.
- 7:58Speaker 1: So in a lab test you'd actually see the box
- 8:00Speaker 1: shape get.
- 8:00Speaker 2: Distorted, grossly distorted. The face will literally dish inwards or
- 8:05Speaker 2: bulge outwards. That localized bending and yielding is the classic
- 8:11Speaker 2: failure mode, especially in your typical kN N connections.
- 8:14Speaker 1: That's a powerful image the HSS face bending like a
- 8:18Speaker 1: flexible plate. What's the second failure mode?
- 8:21Speaker 2: The second one is cord sheer yielding. A lot of
- 8:24Speaker 2: people call it punching sheer.
- 8:26Speaker 1: Okay, so that sounds like what it is. The branch
- 8:28Speaker 1: is literally trying to punch a hole through the cord.
- 8:30Speaker 2: That's a perfect way to think about it. It happens
- 8:32Speaker 2: when the load is really concentrated, and it typically governs
- 8:35Speaker 2: when you have a high branch to chord with ratio,
- 8:38Speaker 2: you're basically exceeding the sheer yield stress of the steel
- 8:42Speaker 2: around the perimeter of the branch.
- 8:44Speaker 1: Makes sense. And number three you mentioned something about uneven
- 8:47Speaker 1: load distribution.
- 8:48Speaker 2: Correct, that's a local yielding. Due to uneven load distribution,
- 8:52Speaker 2: the stress from the branch isn't uniform where it connects,
- 8:54Speaker 2: so you get these hot spots, these stress concentrations that
- 8:57Speaker 2: can trigger a premature failure, and this is.
- 9:00Speaker 1: Common in a specific type of connection.
- 9:02Speaker 2: It's the most common failure mode for overlapped K connections.
- 9:05Speaker 2: In rectangular HSS, you'll often see the compression branch start
- 9:09Speaker 2: to locally buckle right at the connection.
- 9:11Speaker 1: And the final one Number four is about the size
- 9:14Speaker 1: of the HSS YEP.
- 9:15Speaker 2: That's cord or column sidewall failure. This can be either
- 9:19Speaker 2: sidewall crippling or local buckling. It's mainly a concern when
- 9:23Speaker 2: your branch is in compression and it's basically trying to
- 9:27Speaker 2: crush the sidewalls of the cord member.
- 9:29Speaker 1: Okay, so we've established the Achilles heel is that flexible face.
- 9:32Speaker 1: Let's talk about how that plays out in some common
- 9:34Speaker 1: applications like HSS to plate connections.
- 9:37Speaker 2: Yeah, Chapter seven covers this, and this is where the
- 9:40Speaker 2: contrast with a W shape is just so stark.
- 9:43Speaker 1: How So, if you.
- 9:44Speaker 2: Weld plate to the flange of a W shape, the
- 9:47Speaker 2: web is right there directly underneath, providing immediate stiffness and support.
- 9:51Speaker 1: But on an HSS.
- 9:52Speaker 2: On an HSS, you weld the plate to the face
- 9:54Speaker 2: and that force has to travel across that flexible plate
- 9:57Speaker 2: to get to the remote sidewalls for support. The load
- 10:00Speaker 2: path is completely different.
- 10:02Speaker 1: So you're getting all this localized bending in the face plate, a.
- 10:05Speaker 2: Ton of it, and the result is that HSS plastification.
- 10:08Speaker 2: That face pending we talked about is almost always the
- 10:11Speaker 2: dominant limit state. It controls the design. You often hit
- 10:14Speaker 2: a deformation limit long before you hit an actual strength limit.
- 10:18Speaker 1: What if you have a really high load though? Is
- 10:20Speaker 1: there a way to reinforce that connection?
- 10:22Speaker 2: There is for maximum capacity. You can actually slot the
- 10:26Speaker 2: plate all the way through the HSS and weld it
- 10:28Speaker 2: to both the front and the back.
- 10:30Speaker 1: Face, and that would double the strength.
- 10:33Speaker 2: Theoretically, yes, for a rectangular HSS you can take the
- 10:36Speaker 2: nominal strength as twice that of a standard one sided
- 10:39Speaker 2: plate connection.
- 10:40Speaker 1: But my sense of but fabricators must hate that, Oh
- 10:44Speaker 1: they do.
- 10:45Speaker 2: Doubling the strength on paper is great, but the shop
- 10:47Speaker 2: complexity is huge. You need precise slots, perfect fit up,
- 10:51Speaker 2: and you're doing these really difficult welds inside a joint.
- 10:54Speaker 2: It adds so much time and cost.
- 10:55Speaker 1: Right, it's a classic engineering trade off. The elegant solution
- 10:59Speaker 1: on paper might be a nightmare to actually build exactly. Okay,
- 11:02Speaker 1: what about HSS to HSS trust connections you had, pas
- 11:05Speaker 1: wyse ks. What's the big takeaway from.
- 11:07Speaker 2: Chapter eight if we connect this to the bigger picture,
- 11:10Speaker 2: It's that the size of your trust members is very
- 11:12Speaker 2: often governed by the connection design, not just the member's
- 11:17Speaker 2: axial capacity.
- 11:18Speaker 1: So you pick a chord that's perfectly fine for the
- 11:20Speaker 1: span and the overall trust loads.
- 11:23Speaker 2: But when you check the connection, you find the cord
- 11:26Speaker 2: face is way too flexible and the joint just doesn't work.
- 11:29Speaker 2: So you're forced to go back and pick a heavier,
- 11:31Speaker 2: stockier chord member just to make the connection.
- 11:33Speaker 1: Pass, which brings us to the Golden rules. The guy
- 11:36Speaker 1: gives some great tips for designing economical unreinforced connections. What
- 11:41Speaker 1: are they?
- 11:42Speaker 2: Yeah, the goal is always to avoid reinforcement. If you can,
- 11:45Speaker 2: it's cheaper and it looks better. The two rules are
- 11:47Speaker 2: basically two sides of the same coin. When one is
- 11:50Speaker 2: select relatively stocky chord members.
- 11:53Speaker 1: And define stocky fir us. What kind of numbers are
- 11:55Speaker 1: we talking about.
- 11:55Speaker 2: We're talking about the slenderness ratio. So for around HSS,
- 11:58Speaker 2: you want a diameter to thickness ratio d over T
- 12:01Speaker 2: somewhere between say fifteen.
- 12:03Speaker 1: And thirty and for rectangu.
- 12:05Speaker 2: For rectangular you want the width the thickness ratio b
- 12:08Speaker 2: over t to be in that sweet spot of about
- 12:11Speaker 2: fifteen to twenty five. If you go much higher than that,
- 12:14Speaker 2: the connection efficiency just plummets.
- 12:17Speaker 1: Okay, so stocky chords are key. What's the second Golden rule?
- 12:21Speaker 2: Rule two is basically the opposite. For the branches, select
- 12:24Speaker 2: relatively thin branch members. Now they still have to be
- 12:27Speaker 2: strong enough for the axial load, of course, but you.
- 12:29Speaker 1: Want them to be thin walled. That seems kennterintuitive.
- 12:32Speaker 2: Thin walled, but with large outside dimensions. The idea is
- 12:36Speaker 2: to spread the load out over a larger area of
- 12:38Speaker 2: that flaccible cord face. A wider branch reduces the localized pressure.
- 12:43Speaker 1: Ah okay, so it's this elegant balance. You use a
- 12:46Speaker 1: stocky stiff cord to resist the deformation and then a wide,
- 12:50Speaker 1: thin branch to distribute the load as gently as possible.
- 12:53Speaker 2: That's the perfect summary of the design philosophy.
- 12:56Speaker 1: Well, that pretty much brings our deep dive to a close.
- 12:58Speaker 1: We've covered the unique failure modes that constant thread of plastification,
- 13:02Speaker 1: punching sheer, and sidewall failure, and.
- 13:04Speaker 2: We've really hammered home that core philosophy. You have to
- 13:07Speaker 2: design for the flexibility of the chord face by choosing stocku.
- 13:10Speaker 1: Members, understanding that the local bending of that face is
- 13:14Speaker 1: what governs the capacity. That's the single biggest lesson for
- 13:18Speaker 1: any designer moving from W shapes to HSS.
- 13:20Speaker 2: Absolutely. So to help lock all this in, I have
- 13:23Speaker 2: a little review exercise for you.
- 13:25Speaker 1: Let's hear it.
- 13:25Speaker 2: Okay, imagine you're designing a K connection in a big
- 13:29Speaker 2: outdoor trusts. You select a rectangular HSS for your chord member,
- 13:33Speaker 2: and it happens to have a with to thickness ratio
- 13:36Speaker 2: ab over t of forty.
- 13:38Speaker 1: Okay, b over t of forty based on the Golden
- 13:41Speaker 1: rules we just talked about, which primary failure mode is
- 13:45Speaker 1: that selection practically screaming for, and what's the immediate fix?
- 13:49Speaker 2: Yeah, that b over t of forty is way outside
- 13:51Speaker 2: that efficient range of fifteen to twenty five we talked about.
- 13:54Speaker 2: It's a very slender, very flexible face.
- 13:56Speaker 1: So it's a near guarantee that you're going to fail
- 13:58Speaker 1: in cord.
- 13:58Speaker 2: Wall plastification that is going to bend and yield long
- 14:02Speaker 2: before you get anywhere near the capacity of the members themselves.
- 14:05Speaker 1: And the immediate design remedy isn't some complicated reinforcement plate
- 14:08Speaker 1: or slotted connection.
- 14:10Speaker 2: Note, the simplest, most economical fix is to go back
- 14:13Speaker 2: to the drawing board and select a different cord member,
- 14:16Speaker 2: a stockier one with a lower b over t ratio
- 14:20Speaker 2: that can transfer that load effectively before the face has
- 14:22Speaker 2: a chance to deform.