Latest / Civil Engineering Made Simple / Concrete and Masonry Databook
Transcript
- 0:00Speaker 1: Welcome to the deep dive, the place where we take
- 0:02Speaker 1: these massive engineering standards and technical specs and really try
- 0:06Speaker 1: to turn them into knowledge you can actually use. Today,
- 0:10Speaker 1: we're on a pretty crucial mission condensing the fundamental performance
- 0:15Speaker 1: data for concrete and masonry. I mean, these are the
- 0:18Speaker 1: bedrock materials of our industry.
- 0:20Speaker 2: That's exactly it. And this isn't going to be some
- 0:23Speaker 2: you know, high level theoretical chat. We are pulling the
- 0:26Speaker 2: most critical numbers and practices directly from the source, the
- 0:29Speaker 2: ASTM and ACI standards you're supposed to have memorized. The
- 0:32Speaker 2: goal is to get straight to the why and the how,
- 0:35Speaker 2: the engineering principles that you know, really prevent failure and
- 0:38Speaker 2: make sure things last out in the field.
- 0:40Speaker 1: Okay, so let's start at the beginning, the binder, the
- 0:43Speaker 1: literal glue of the whole industry. When we talk cement,
- 0:46Speaker 1: we're mostly talking about Portland cement.
- 0:48Speaker 2: Yep. Your core types really Type I for general use
- 0:52Speaker 2: and then types two in V. When you start worrying
- 0:54Speaker 2: about sulfate resistance, that's all under ASTMC one fifty.
- 0:57Speaker 1: But that's not the whole story anymore.
- 0:59Speaker 2: Is it not at all? I mean the reality of
- 1:02Speaker 2: modern construction is blended cements. That's astm C five ninety five.
- 1:07Speaker 2: We use them all the time. Now for better performance sustainability,
- 1:10Speaker 2: you can really tailor the properties.
- 1:12Speaker 1: So we take that cement at aggregates and water and
- 1:15Speaker 1: we're ready to lay some brick. We've made mortar and mortar,
- 1:18Speaker 1: as I'm learning, is a totally different animal.
- 1:22Speaker 2: It is a completely different animal governed by ASTMC two seventy.
- 1:25Speaker 2: And you've got five main types to know, msno, and
- 1:29Speaker 2: K Okay.
- 1:30Speaker 1: So break that down. M must be the strongest, exactly.
- 1:33Speaker 2: Type M is the workhorse. It's the highest compressive strength,
- 1:36Speaker 2: and it's what you're required to use for say, below
- 1:39Speaker 2: grade exterior walls or any heavy load bearing work.
- 1:41Speaker 1: And on the other end of that spectrum.
- 1:43Speaker 2: That would be type K. It's got a really high
- 1:45Speaker 2: lime content, so it's much softer, lower strength. You really
- 1:48Speaker 2: only see it used for repointing historic buildings where you
- 1:51Speaker 2: need more flexibility than sheer strength.
- 1:53Speaker 1: Now, this is where it gets really interesting for me,
- 1:55Speaker 1: the handling of fresh mortar. There's a rule here that
- 1:58Speaker 1: seems to defy everything you learn about concrete.
- 2:01Speaker 2: You're talking about retempering exactly, retampering, right, So This is
- 2:04Speaker 2: the controlled edition of water to mortar that started to
- 2:07Speaker 2: stiffen up on the board.
- 2:09Speaker 1: Which sounds like a huge mistake.
- 2:10Speaker 2: In concrete it would be, but the standards for mortar
- 2:14Speaker 2: they explicitly permit it. In fact is often critical and
- 2:17Speaker 2: the number to remember is two and a half hours.
- 2:21Speaker 2: You can retemper mortar for up to two point five
- 2:24Speaker 2: hours after you first mix.
- 2:25Speaker 1: It, and it actually improves the bond.
- 2:27Speaker 2: It does. It improves workability and maximizes the bond strength
- 2:31Speaker 2: between the mortar and the unit. It's a standard accepted practice.
- 2:35Speaker 1: Okay, so what if you're doing everything right retempering within
- 2:38Speaker 1: the window, but you're still getting a weak bond. What's
- 2:42Speaker 1: the metric to check?
- 2:43Speaker 2: Then you need to look at water retentivity. It's a
- 2:45Speaker 2: flow test and it basically measures how well the mortar
- 2:48Speaker 2: holds onto its water when you put it on a
- 2:50Speaker 2: thirsty brick.
- 2:51Speaker 1: So the brick is literally sucking the water out.
- 2:53Speaker 2: It is, and if the mortar has low retentivity, the
- 2:56Speaker 2: brick sucks the water out too fast, the cement doesn't
- 2:59Speaker 2: hydrate proper at that interface, and you're left with a weak,
- 3:02Speaker 2: crumbly bond. It's a failure of the cure.
- 3:06Speaker 1: Let's pivot to the chemical helpers here. Yeah, AD mixtures,
- 3:09Speaker 1: we usually classify them by what they do right, Accelerators retarders.
- 3:13Speaker 2: Yeah, accelerators speed up the set. Retarders slow it down,
- 3:15Speaker 2: which is great in hot weather air and training agents
- 3:18Speaker 2: for free thaw durability, and of course super plasticizers to
- 3:22Speaker 2: get that high slump without adding too much water.
- 3:25Speaker 1: Now, on this topic, there's a safety warning in the
- 3:28Speaker 1: source material. That's well, it's an all.
- 3:31Speaker 2: Cass and it should be. This is life's safety critical.
- 3:34Speaker 2: There is no such thing as an anti freeze AD
- 3:37Speaker 2: mixture for masonry, grout, air, mortar, full stop.
- 3:41Speaker 1: So you can't just dump something in the mix for
- 3:43Speaker 1: a cold weather.
- 3:43Speaker 2: Poor Absolutely not, It's dangerous. The only way to do
- 3:47Speaker 2: it right is with external heat blankets and maintaining the
- 3:50Speaker 2: proper curing temperatures. There are no chemical shortcuts.
- 3:53Speaker 1: That's a huge takeaway. Okay, stepping back from the chemistry
- 3:57Speaker 1: to the bulk of the mix, the aggregates. Why is
- 4:00Speaker 1: grating so important?
- 4:01Speaker 2: It all comes down to one word, voids. A well
- 4:04Speaker 2: graded mix has everything from big particles to small ones.
- 4:07Speaker 2: They nestle together really efficiently.
- 4:08Speaker 1: Like filling a jar with rocks and then pouring in
- 4:10Speaker 1: sand to fill.
- 4:11Speaker 2: The gaps precisely, you reduce the empty space, you get denser,
- 4:14Speaker 2: stronger concrete, and maybe more importantly for the budget, you
- 4:17Speaker 2: use less of the expensive ingredient, which is the cement paste.
- 4:21Speaker 1: And we break these down into normal weight and lightweight.
- 4:24Speaker 2: Right ASTMC thirty three for normal and C three thirty
- 4:27Speaker 2: or C three thirty one for lightweight, And for structural
- 4:30Speaker 2: lightweight aggregate, there is a very specific number you have
- 4:33Speaker 2: to hit. The maximum dry loose density cannot be more
- 4:37Speaker 2: than fifty five pounds per cubic foot.
- 4:39Speaker 1: So if it comes in heavier than that, you're not
- 4:41Speaker 1: getting the structural efficiency you paid for.
- 4:43Speaker 2: You're not and you could be messing up the deadload
- 4:45Speaker 2: calculations for the whole building.
- 4:47Speaker 1: All right, let's shift from ingredients to performance ultimate strength.
- 4:51Speaker 1: The numbers here are pretty.
- 4:53Speaker 2: Dramatic, they really are. A fired clay brick can go
- 4:56Speaker 2: from two thousand psi all the way up to a
- 4:58Speaker 2: staggering twenty thousand ps.
- 5:00Speaker 1: Wow, and concrete masonry units.
- 5:03Speaker 2: A much tighter range, typically somewhere between fifteen hundred and
- 5:06Speaker 2: maybe six thousand psi and tied.
- 5:08Speaker 1: Directly to that strength is stiffness, the modulus of elasticity
- 5:11Speaker 1: or a cat it is.
- 5:13Speaker 2: And here's a subtle but critical warning for designers. If
- 5:16Speaker 2: you're working with high strength concrete and that's anything over
- 5:19Speaker 2: six thousand psi, the standard ACI three eighteen equations tend
- 5:24Speaker 2: to overestimate.
- 5:25Speaker 1: Its stiffness overestimate. So what's the actual risk there? What
- 5:29Speaker 1: does that mean for this structure?
- 5:30Speaker 2: It means you're underestimating how much it will deflect or bend.
- 5:35Speaker 2: You think it's stiffer than it actually is, so you
- 5:38Speaker 2: could end up with serviceability failures like unexpected cracking under
- 5:42Speaker 2: normal loads, even though the building is technically strong enough.
- 5:45Speaker 1: That's a big deal. Okay, let's talk thermal properties. Our value.
- 5:48Speaker 2: Yeah, the contrast here is just stark. You take a
- 5:51Speaker 2: dedicated insulator like extrude in polystyrene and you're getting an
- 5:54Speaker 2: OUR value of about five per inch. In a common brick,
- 5:57Speaker 2: maybe are zero point one pint one to our zero
- 6:00Speaker 2: point four to five per inch. It just shows you
- 6:02Speaker 2: that mass and insulation are two completely different things.
- 6:05Speaker 1: Which also plays into fire resistance. Right, It's all about
- 6:07Speaker 1: thickness and what's inside exactly.
- 6:09Speaker 2: It's not just about how thick the wall is. It's
- 6:11Speaker 2: about its composition. So for example, to get a two
- 6:14Speaker 2: hour fire rating, you might need a three point eight
- 6:16Speaker 2: inch thick solid brick. But if you're using hollow units,
- 6:20Speaker 2: even if you fill them with sand or grout, you
- 6:22Speaker 2: might need a thicker wall, say four point four inches,
- 6:26Speaker 2: to get that same to hour rating. The fill completely
- 6:29Speaker 2: changes the thermal dynamics.
- 6:31Speaker 1: Now for what might be the biggest headache of all
- 6:34Speaker 1: volume control.
- 6:37Speaker 2: Cracks, the inevitable cracks. I mean, all materials expand and
- 6:40Speaker 2: contract with temperature, but cement based products they have this
- 6:43Speaker 2: extra layer of complexity. They undergo permanent initial shrinkage.
- 6:47Speaker 1: And that's from the chemical reaction itself.
- 6:50Speaker 2: Yes, from hydration and water evaporation. And this happens on
- 6:53Speaker 2: top of any normal thermal movement. We're talking about real
- 6:55Speaker 2: movement too. It can be up to a sixteenth of
- 6:58Speaker 2: an inch over just ten feet.
- 7:00Speaker 1: How do you manage that?
- 7:01Speaker 2: With joints? Three types. Really, you have isolation joints to
- 7:04Speaker 2: separate a slab from something fixed like a column. You
- 7:08Speaker 2: have construction joints, which are just your planed stopping points
- 7:11Speaker 2: between pores.
- 7:12Speaker 1: And then the big one for cracks the control joints.
- 7:14Speaker 2: Exactly, or contraction joints. These are just pre planned weak spots,
- 7:18Speaker 2: usually a saw cut, that tell the cracks where to
- 7:20Speaker 2: form neatly instead of letting them pop up randomly all
- 7:23Speaker 2: over the slab.
- 7:24Speaker 1: And there's a rule of thumb for spacing those right
- 7:26Speaker 1: here is.
- 7:27Speaker 2: For a slab on ground, your joint spacing shouldn't be
- 7:30Speaker 2: more than twenty four to thirty six times the slab's thickness.
- 7:33Speaker 2: You can push towards the thirty six times multiplier if
- 7:36Speaker 2: you have a good low slump mix with larger aggregate.
- 7:40Speaker 2: If it's a wetter mix, you need to keep them tighter,
- 7:42Speaker 2: closer to twenty four times.
- 7:43Speaker 1: Got it. Let's talk about the units themselves, the masonry.
- 7:47Speaker 1: There's a whole language here course, whythe stretcher m HM.
- 7:51Speaker 2: A course is a horizontal layer, a wife is a
- 7:54Speaker 2: vertical section that's one unit deep. But the most important
- 7:57Speaker 2: thing to remember for specs is the dimensioning. Specified dimension
- 8:00Speaker 2: is what you can actually measure, and that's.
- 8:02Speaker 1: Always smaller than the nominal dimension.
- 8:04Speaker 2: Right, it's typically thirty eight of an inch less to
- 8:06Speaker 2: account for the mortar joint.
- 8:08Speaker 1: Okay, so before you even lay that first brick, there's
- 8:10Speaker 1: a quality control test.
- 8:11Speaker 2: You have to do a critical one for clay brick.
- 8:14Speaker 2: You have to check its initial rate of absorption or IRA, basically,
- 8:18Speaker 2: how thirsty is it?
- 8:19Speaker 1: And you can do this in the field.
- 8:21Speaker 2: Yeah, it's a great simple field test. You draw a
- 8:24Speaker 2: circle on the brick with a crayon about the size
- 8:26Speaker 2: of a quarter. Then you use a medicine dropper and
- 8:28Speaker 2: put exactly twelve drops of water inside that.
- 8:31Speaker 1: Circle and you time it.
- 8:32Speaker 2: You time it. If that water gets absorbed in less
- 8:35Speaker 2: than one minute, the brick has high suction, it's too dry,
- 8:38Speaker 2: and you have to prewet it or it will kill
- 8:40Speaker 2: your mortar bond.
- 8:41Speaker 1: Okay, So this leads to a huge practical difference. You
- 8:44Speaker 1: wet thirsty brick, but you should You.
- 8:46Speaker 2: Should never wet concrete block before you lay it. Why
- 8:50Speaker 2: not because concrete block will swell up when it gets wet.
- 8:53Speaker 2: Then as it dries out inside the finished wall, it shrinks,
- 8:56Speaker 2: and that shrinkage is a major cause of cracking. A
- 9:00Speaker 2: fundamental difference in practice. You just have to know.
- 9:02Speaker 1: Let's move to the steel inside all this reinforcement.
- 9:06Speaker 2: You've got your standard rebar welded wire fabric, and then
- 9:09Speaker 2: your high strength stuff for pre stressing, usually Grade two
- 9:12Speaker 2: fifty or Grade two seventy wire and strands.
- 9:14Speaker 1: And protecting that steel from corrosion is everything.
- 9:17Speaker 2: It is, especially for joint reinforcement. The level of protection
- 9:21Speaker 2: depends on where it is. For an interior wall in
- 9:25Speaker 2: a dry space, a simple zinc coating might.
- 9:28Speaker 1: Be fine, but for outside for.
- 9:31Speaker 2: Severe exterior exposure, you have to step up to hot
- 9:34Speaker 2: dip galvanized steel, or for the absolute best protection, like
- 9:38Speaker 2: in a pool environment, you need Type three or four
- 9:41Speaker 2: stainless steel.
- 9:42Speaker 1: And this brings up that classic problem galvanic corrosion, when
- 9:46Speaker 1: you have two different metals touching absolutely.
- 9:48Speaker 2: The simple principle is this the less noble metal the
- 9:51Speaker 2: anode is the one that corrodes. If that anode is
- 9:54Speaker 2: a tiny little fastener attached to a huge metal panel,
- 9:57Speaker 2: all the corrosive energy gets focused on that tiny.
- 10:00Speaker 1: Spot and it just eats it away.
- 10:01Speaker 2: It can corrode one hundred, even a thousand times faster.
- 10:04Speaker 2: So the rule is your fastener must always be more
- 10:07Speaker 2: noble than the bigger piece of metal.
- 10:09Speaker 1: It's holding good to know. Briefly, on form work, we
- 10:12Speaker 1: see a lot of plywood but also those fiber tubes
- 10:14Speaker 1: for columns.
- 10:15Speaker 2: Yeah, son A tube is a common brand name.
- 10:17Speaker 1: Yeah.
- 10:17Speaker 2: Just remember if you're bending plywood for curve forms, the
- 10:20Speaker 2: limits are pretty tight. A three quarter inch sheet needs
- 10:23Speaker 2: a twelve foot radius to bend across the grain.
- 10:25Speaker 1: And what about shot crete pneumatically applied concrete with shot.
- 10:29Speaker 2: Create you have to budget for waste. It's called rebound loss.
- 10:33Speaker 2: For a floor, it might only be a five to
- 10:34Speaker 2: fifteen percent, but if you're shooting overhead you could lose
- 10:38Speaker 2: twenty five to fifty percent of your material. That's a
- 10:40Speaker 2: huge cost if you don't plan for it.
- 10:42Speaker 1: Okay, last thing in this section, and it's critical finishing
- 10:46Speaker 1: a concrete slab. When do you start?
- 10:50Speaker 2: The rule is simple and it's all about safety and quality.
- 10:54Speaker 2: You wait until the water sheen is gone from the
- 10:56Speaker 2: surface and the concrete is firm enough to support your
- 10:58Speaker 2: weight without you sinking in more than a quarter of
- 11:00Speaker 2: an inch.
- 11:01Speaker 1: And if you jump the gun, if you start finishing
- 11:04Speaker 1: while that bleed water is still there, oh, that's.
- 11:06Speaker 2: One of the worst things you can do. You're trapping
- 11:08Speaker 2: a weak, watery layer of paste right at the surface.
- 11:12Speaker 2: It guarantees you'll get defects later on scaling, crazing, dusting.
- 11:15Speaker 2: You've just destroyed the durability of that slab surface.
- 11:19Speaker 1: All right, Let's talk about some of the bigger systems.
- 11:21Speaker 2: Foundations, right, footings, piles, piers. They're almost always reinforced concrete
- 11:27Speaker 2: because you need that compressive strength and you need it
- 11:29Speaker 2: to last underground. But the design is all about the
- 11:32Speaker 2: site conditions.
- 11:33Speaker 1: You mean frost depth than what the soil can hold exactly.
- 11:36Speaker 2: The foundation has to go below the local frost depth
- 11:39Speaker 2: to prevent frost heave from lifting the building, and the
- 11:43Speaker 2: size of your footings depends entirely on the soil's bearing capacity.
- 11:47Speaker 2: The difference is enormous. Crystalline bedwalk might hold twelve thousand
- 11:53Speaker 2: pounds per square foot. In clay, you might only get
- 11:56Speaker 2: two thousand. That difference dictates the entire footprint of your foundation.
- 12:00Speaker 1: With precast construction, we get into pre stressing. What's the
- 12:04Speaker 1: simple difference between pretensioning and post tensioning.
- 12:07Speaker 2: It's all about timing. Pre Tensioning is when you stress
- 12:09Speaker 2: the steel tendons before you pour the concrete. Then you
- 12:12Speaker 2: release the tension and it transfers compression into the hardened.
- 12:15Speaker 1: Concrete and post tensioning is the opposite.
- 12:17Speaker 2: Right, With post tensioning, you pour the concrete first, let
- 12:20Speaker 2: it cure, and then you thread the tendons through ducks
- 12:22Speaker 2: and stress them after the concrete is already strong.
- 12:25Speaker 1: When you're lifting those big precast panels on site, what's
- 12:28Speaker 1: the number one rule.
- 12:29Speaker 2: The center of gravity must always be inside the bearing
- 12:33Speaker 2: area of the lifting points. If it shifts outside that zone,
- 12:36Speaker 2: the panel will flip. It'll rotate uncontrollably. It's a huge
- 12:40Speaker 2: safety hazard and an easy way to destroy a very
- 12:43Speaker 2: expensive panel.
- 12:44Speaker 1: Finally, retaining walls gravity walls versus cantilever walls.
- 12:48Speaker 2: A gravity wall just uses its own immense weight to
- 12:51Speaker 2: hold back the soil. A reinforced cantilever wall is more elegant.
- 12:55Speaker 2: It uses steel reinforcement and its footing design to resist
- 12:58Speaker 2: the pressure.
- 12:59Speaker 1: And those pop segmental retaining walls, the.
- 13:01Speaker 2: Stacked blocks with SRW's, there's a limit to how high
- 13:05Speaker 2: you can build them. That maximum height depends directly on
- 13:08Speaker 2: the friction angle of the soil behind it and the
- 13:10Speaker 2: geometry of the blocks themselves, their depth, and their batter
- 13:13Speaker 2: or setback. It's a precise engineering balance.
- 13:16Speaker 1: We've covered a ton of ground here, I mean from
- 13:18Speaker 1: the fifty five pound per cubic foot limit for lightweight
- 13:21Speaker 1: aggregate all the way to that two point five hour
- 13:23Speaker 1: window for retempering mortar. This is the kind of data
- 13:26Speaker 1: that really separates a knowledgeable engineer from someone who's just guessing.
- 13:31Speaker 2: Absolutely, knowing these standards isn't about passing a test. It's
- 13:35Speaker 2: about making smart decisions in the field that save money
- 13:38Speaker 2: and ensure the structure is sound. So before we wrap up,
- 13:41Speaker 2: let's put two of these ideas head to head.
- 13:43Speaker 1: Okay, let's call this the field manager's test.
- 13:45Speaker 2: Here's the scenario. You are supervising a new concrete slab
- 13:49Speaker 2: on ground pore. It's a high slump mix. At the
- 13:53Speaker 2: same time, your masons are laying a wall that needs
- 13:55Speaker 2: Type M mortar.
- 13:56Speaker 1: Okay, Task one, explain the risk of premature face. Why
- 14:01Speaker 1: do you have to stop your crew from hitting that
- 14:03Speaker 1: slab as soon as it's struck off and what specific
- 14:06Speaker 1: defects are you trying to prevent?
- 14:07Speaker 2: And Task two, your mason comes to you and says
- 14:10Speaker 2: his Type M mortar, which was mixed ninety minutes ago,
- 14:13Speaker 2: has gotten stiff based on the standards we just discussed.
- 14:15Speaker 2: Are you all love to tell him to add water
- 14:17Speaker 2: to retemper it. You have to justify your answer with
- 14:20Speaker 2: that time limit.
- 14:21Speaker 1: Think about that fundamental difference in the standards right how
- 14:23Speaker 1: we treat fresh concrete versus fresh mortar, especially with water.
- 14:27Speaker 1: Getting that right is the key. Thanks for diving deep
- 14:30Speaker 1: with us.