Latest / Civil Engineering Made Simple / Steel Design Guide :Stiffening of Wide-Flange Columns at Moment Connections [Wind and Seismic Applications]
Transcript
- 0:00Speaker 1: All right, welcome back to the deep dive. Today. We
- 0:03Speaker 1: are getting into some heavy steel. We're doing a full
- 0:06Speaker 1: deep dive into AISC Design Guide thirteen, which is really
- 0:10Speaker 1: the go to reference for stiffening of wide flange columns
- 0:14Speaker 1: at moment connections.
- 0:15Speaker 2: Yeah, and our goal here is to really break this
- 0:19Speaker 2: technical guide down into a clear blueprint for you. We're
- 0:22Speaker 2: going to go past just the strength checks and get
- 0:24Speaker 2: into the engineering philosophy, the constructibility, and maybe most importantly,
- 0:29Speaker 2: the economics that drive the decision do we add stiffeners
- 0:33Speaker 2: or do we just buy a bigger column.
- 0:35Speaker 1: It's such a fundamental problem. I mean, if you've ever
- 0:37Speaker 1: looked at the steel moment frame, you know that column
- 0:39Speaker 1: has to take these massive forces from the beams, especially
- 0:42Speaker 1: during say a big wind event or an earthquake. So
- 0:45Speaker 1: what is DG thirteen actually trying to prevent from happening
- 0:47Speaker 1: right at that joint.
- 0:48Speaker 2: It's all about preventing a local failure, a catastrophic one.
- 0:52Speaker 2: When a beam sees a huge moment, its flangers are
- 0:55Speaker 2: literally pulling on one side of the column and pushing
- 0:57Speaker 2: on the.
- 0:57Speaker 1: Other, So you have this tension and compression couple.
- 0:59Speaker 2: Eggs exactly, and that sends these incredibly high concentrated forces
- 1:04Speaker 2: right into the column's web and flanges. If that column
- 1:08Speaker 2: isn't strong enough right at that specific point, those forces
- 1:11Speaker 2: can make it cripple or buckle locally, long before the
- 1:14Speaker 2: wider frame gets a chance to do its job and
- 1:16Speaker 2: dissipate the energy.
- 1:17Speaker 1: Okay, so let's unpack that. The load pass is everything
- 1:20Speaker 1: you mentioned concentrated forces. How do we actually put a
- 1:24Speaker 1: number on that force coming from the beam?
- 1:27Speaker 2: We define it using the moment arm. So you take
- 1:29Speaker 2: the total design moment that the beam is applying. You
- 1:32Speaker 2: divide it by the distance between the center lines of
- 1:34Speaker 2: those two beam flanges, the.
- 1:35Speaker 1: Vertical distance between the top and bottom flange forces.
- 1:38Speaker 2: That's the one and that gives us this critical value
- 1:41Speaker 2: we call the factored flange force, usually written as PCEBUF.
- 1:45Speaker 2: That single force is what we use for pretty much
- 1:48Speaker 2: all of our local checks on the column.
- 1:49Speaker 1: So p WUF is the number we're designing against. Now
- 1:52Speaker 1: where does that force go? It hits the column flange
- 1:55Speaker 1: and then.
- 1:56Speaker 2: When right so it creates this very clear load path.
- 2:00Speaker 2: The force lands on the column flange, which acts like
- 2:03Speaker 2: a stiff little plate. From there it spreads out and
- 2:06Speaker 2: funnels into the column.
- 2:07Speaker 1: Web, and that section of the web right between where
- 2:09Speaker 1: the beam flanges connect that has a specific name, right it.
- 2:13Speaker 2: Does, We call that the panel zone. That specific rectangle
- 2:15Speaker 2: of the web sees some really high sheer stress, and
- 2:19Speaker 2: ultimately all of this is balanced out by axial forces
- 2:22Speaker 2: that develop in the main column flanges outside of that
- 2:25Speaker 2: connection area.
- 2:27Speaker 1: That makes perfect sense. Now. One thing about DG thirteen
- 2:30Speaker 1: that's really interesting is how it immediately splits the problem
- 2:33Speaker 1: into two very different design approaches. You've got wind and
- 2:37Speaker 1: low seismic on one hand, and high seismic on the other.
- 2:40Speaker 1: Why is that distinction so important?
- 2:42Speaker 2: Because you're designing for totally different behaviors, and when or
- 2:45Speaker 2: low sizemic zones, we're typically just following standard LRFD specs.
- 2:49Speaker 2: The design moment we're using is rarely the full strength
- 2:53Speaker 2: of the beam, So a lot of the time the
- 2:55Speaker 2: column can pass the local checks on its own, so you.
- 2:57Speaker 1: Can often get away with no stiffeners at all.
- 3:00Speaker 2: That's the ideal scenario. Yeah, rely on the column's bare strength.
- 3:04Speaker 2: But when you get into high seismic areas, so special
- 3:07Speaker 2: or intermediate moment frames SMF or IMF, you're now expecting
- 3:11Speaker 2: that connection to yield to go in elastic.
- 3:14Speaker 1: Ah, so you're actually designed and for it to deform exactly.
- 3:17Speaker 2: You're designing for ductility and energy dissipation, not just you know,
- 3:21Speaker 2: surviving elastically. So for those you have to follow the
- 3:24Speaker 2: AISC seismic provisions. We generally mandate transverse stiffeners, not just
- 3:30Speaker 2: because the column might fail a strength check, but because
- 3:32Speaker 2: we need the extra stiffness to make sure the connection
- 3:34Speaker 2: behaves properly during those repeated cyclic earthquake loads.
- 3:38Speaker 1: It's a total shift from a strength based design to
- 3:41Speaker 1: a stiffness based one, it really is. Okay, before we
- 3:44Speaker 1: dive into the five local checks, we have to talk
- 3:46Speaker 1: about the panel's own sheer strength. This is kind of
- 3:48Speaker 1: the big picture check for that whole web area.
- 3:50Speaker 2: Is Yeah, that's a great way to put it. It's
- 3:52Speaker 2: a check for the web's capacity within the depth of
- 3:54Speaker 2: the beam. The sheer force in that panel is a
- 3:58Speaker 2: combination of the moments from the beams and the overall
- 4:01Speaker 2: story share. The guide gives us formulas for it, and
- 4:05Speaker 2: they can get a little complex depending on the axial
- 4:07Speaker 2: load on the column.
- 4:09Speaker 1: How does the columns existing axial load play into that.
- 4:12Speaker 2: It's a huge factor. It directly reduces the web's ability
- 4:15Speaker 2: to handle that shear. The formulas actually have a term
- 4:19Speaker 2: for the ratio of the factored axial load p subu
- 4:22Speaker 2: to the column's axial yield capacity pace of by.
- 4:25Speaker 1: So if the column is already being squeezed pretty.
- 4:27Speaker 2: Hard, right, if that PU over py ratio is high,
- 4:30Speaker 2: the web is already stressed out. Its ability to take
- 4:33Speaker 2: on more shear from the beams drops, and it drops
- 4:35Speaker 2: off pretty fast. That's why you have to check the
- 4:37Speaker 2: panel zone even if all the other local checks pass.
- 4:40Speaker 1: That makes a lot of sense. You're checking to see
- 4:42Speaker 1: if the column is already halfway to its limit before
- 4:44Speaker 1: the lateral load even shows up. Okay, so let's pivot
- 4:47Speaker 1: to those local weak spots. For a standard wind or
- 4:51Speaker 1: low seismic design, there are five critical limit states we
- 4:55Speaker 1: check against that pce of UF. What are the main
- 4:58Speaker 1: types of failure we're looking for for, Well.
- 5:01Speaker 2: They really fall into two main categories, how the column
- 5:04Speaker 2: flange reacts and then how the column web reacts.
- 5:06Speaker 1: Let's start with the flange itself. What's the key failure
- 5:09Speaker 1: mode there?
- 5:10Speaker 2: That would be local flange bending. This check measures the
- 5:13Speaker 2: column flange's ability to resist being bent out of plane
- 5:17Speaker 2: by a tensile force from the beam. Just imagine the
- 5:19Speaker 2: column flange as a little cantilevered plate that's being pulled
- 5:22Speaker 2: away from the web.
- 5:23Speaker 1: And this is probably worse for certain connection types, right.
- 5:25Speaker 2: Oh, absolutely, it's especially critical when you directly weld the
- 5:29Speaker 2: beam flange to the column, or if you're using something
- 5:31Speaker 2: like an extended end plate connection. The formula for the
- 5:34Speaker 2: check actually changes a bit depending on the connection geometry.
- 5:37Speaker 1: So if the column flange is too thin that tension
- 5:40Speaker 1: force and the beam just peels it.
- 5:42Speaker 2: Right off, that's a good way to visualize it.
- 5:44Speaker 1: Yeah.
- 5:44Speaker 2: Now, if we move from the flange inward to the web,
- 5:47Speaker 2: we've got a few related checks, and.
- 5:49Speaker 1: The first couple are about the steel just yielding, right.
- 5:53Speaker 2: Yes, The first is local web yielding. You check this
- 5:56Speaker 2: for both tension and compression forces. It's basically check looking
- 6:00Speaker 2: to see if the web itself yields right where that
- 6:02Speaker 2: concentrated force from the flan spreads out. And then related
- 6:06Speaker 2: to that is web crippling. This one is only for
- 6:09Speaker 2: a compressive force. It's not yielding so much as a
- 6:12Speaker 2: local buckling failure of the web and it's usually most
- 6:14Speaker 2: critical when the force is applied really close to the
- 6:17Speaker 2: end of the column.
- 6:18Speaker 1: I feel like I remember hearing that web crippling doesn't
- 6:20Speaker 1: actually control the design all that often for bigger columns.
- 6:24Speaker 1: Is that true.
- 6:25Speaker 2: That's a great practical point. For most of the heavy
- 6:28Speaker 2: wide flange shapes we use in moment frames, their web
- 6:31Speaker 2: crippling strength is actually quite high. It really only tends
- 6:34Speaker 2: to govern the design for some of the lighter rolled shapes,
- 6:37Speaker 2: like maybe a W twelve by fifty or a W
- 6:40Speaker 2: ten by thirty three. On a big W fourteen, you're
- 6:42Speaker 2: much more likely to fail in flange bending or web
- 6:45Speaker 2: yielding first.
- 6:46Speaker 1: Okay, and the final local check is one of this
- 6:48Speaker 1: more about gravity loads.
- 6:50Speaker 2: That's compression buckling of the web. This one's a bit
- 6:52Speaker 2: of a niche check. It's only required when you have
- 6:55Speaker 2: two compressive flange forces that are directly opposite each other
- 6:59Speaker 2: on the.
- 6:59Speaker 1: Web, like from beams on both sides of the column.
- 7:02Speaker 2: Exactly if you have beams framing in from both sides
- 7:04Speaker 2: and gravity loads are putting both of their bottom flanges
- 7:07Speaker 2: into compression at the same level, the web is effectively
- 7:10Speaker 2: being squeezed from both directions. That's when you check it.
- 7:14Speaker 1: That sounds like a lot of calculations to run through,
- 7:16Speaker 1: especially if you're trying out different column sizes. I assume
- 7:19Speaker 1: the guide offers.
- 7:19Speaker 2: Some help, a huge help. The appendices in DG thirteen
- 7:23Speaker 2: are a lifesaver. They have tables that list the design
- 7:26Speaker 2: strengths for all five of these limit states for a
- 7:29Speaker 2: whole range of common W shapes. So for a W
- 7:32Speaker 2: fourteen by seventy four, say you don't calculate anything, you
- 7:36Speaker 2: just look up the numbers. If you are required force,
- 7:39Speaker 2: your PWF is higher than any of those five values,
- 7:42Speaker 2: you need stiffeners. It's a fantastic shortcut, and that.
- 7:45Speaker 1: Shortcut leads us directly to the economics. The guide is
- 7:50Speaker 1: very very clear on this point. The most economical solution
- 7:54Speaker 1: is usually to avoid stiffs completely. Why is that? Why
- 7:58Speaker 1: not just weld on a plate instead of buying a
- 8:00Speaker 1: heavier column.
- 8:01Speaker 2: It all comes down to one thing. Fabrication labor. Steel
- 8:04Speaker 2: material is expensive, sure, but the labor involved in detailing, fitting,
- 8:09Speaker 2: and then performing high quality inspected structural welds, that cost
- 8:14Speaker 2: is just skyrocketing.
- 8:16Speaker 1: You're saying. An engineer might look at the table, see
- 8:18Speaker 1: that a W fourteen by fifty three fails a check,
- 8:20Speaker 1: and instead of designing a stiffener, they just spec a
- 8:23Speaker 1: W fourteen by seventy four just to avoid the welding.
- 8:25Speaker 2: That is the classic example from the guide itself. They
- 8:28Speaker 2: show a case where the extra material cost of going
- 8:30Speaker 2: from the fifty three to the seventy four was way
- 8:33Speaker 2: way less than the total cost of fabricating and installing
- 8:35Speaker 2: stiffeners and a web doubler plate. You just eliminate so
- 8:38Speaker 2: much complexity and risk.
- 8:39Speaker 1: And speaking of complexity, the guide seems to have a
- 8:42Speaker 1: particular problem with web doubler plates. Is there some fabrication
- 8:45Speaker 1: nightmare that comes with those?
- 8:47Speaker 2: Oh, there is a very specific nightmare, and it's called
- 8:50Speaker 2: the K area. That's the little filat region where the
- 8:53Speaker 2: column flange curves to meet the web. It's a sensitive
- 8:57Speaker 2: area to put a web doubler plate in. You have
- 9:00Speaker 2: to do a lot of welding with high heat right
- 9:02Speaker 2: in that K area, and historically welding there has caused
- 9:06Speaker 2: huge problems. It can lower the notch toughness of the steel,
- 9:09Speaker 2: making it brittle. Plus all that heat and the shrinkage
- 9:12Speaker 2: as the weld cools can actually distort the column's shape.
- 9:15Speaker 2: The guide basically says, if you can avoid welding in
- 9:18Speaker 2: the k area, do it just upsize the column.
- 9:21Speaker 1: That is a very strong recommendation. Okay, but let's say
- 9:24Speaker 1: we have the stiffin. Maybe the size jump is just
- 9:26Speaker 1: too big, or there are architectural limits. What are the
- 9:30Speaker 1: best practices for doing it economically?
- 9:32Speaker 2: If you can't avoid it, you focus on efficiency. For
- 9:35Speaker 2: transverse stiffeners, the little plates that go perpendicular to the web,
- 9:38Speaker 2: try to use partial depth stiffeners. They're way cheaper than
- 9:41Speaker 2: full depth ones. Because the fabricator doesn't have to carefully
- 9:44Speaker 2: cut and fit them between the column flanges.
- 9:46Speaker 1: It is weld them right to the web right.
- 9:48Speaker 2: And another simple thing is just consistency. Try to limit
- 9:52Speaker 2: how many different thicknesses of plate you're using for stiffeners
- 9:55Speaker 2: across the whole project. The fabricator gains a lot of
- 9:59Speaker 2: efficiency if they're not constantly switching materials.
- 10:02Speaker 1: What about those doubler plates If we really need a
- 10:05Speaker 1: thick one.
- 10:05Speaker 2: For share, So if you need reinforcement that say, thicker
- 10:08Speaker 2: than about five eighths of an inch, the guide suggests
- 10:11Speaker 2: using two thinner plates, one on each side of the
- 10:14Speaker 2: web instead of one really thick one to spread out
- 10:17Speaker 2: the heat exactly. It reduces that localized heat input and
- 10:21Speaker 2: mitigates the risk of distortion and shrinkage from those massive
- 10:25Speaker 2: single pass welds.
- 10:26Speaker 1: Okay, fantastic, So we fail to check and we have
- 10:29Speaker 1: to add stiffeners. We're now in the toolbox section of
- 10:31Speaker 1: the guide. How do we figure out how strong these
- 10:34Speaker 1: new plates need to be?
- 10:35Speaker 2: We use a really practical, simplified approach. The stiffening elements,
- 10:39Speaker 2: whether it's a transverse stiffener or a doubler plate, only
- 10:42Speaker 2: have to carry the force in excess of what the
- 10:44Speaker 2: bare column could already handle, so the column still.
- 10:47Speaker 1: Does some of the work. If the column is good
- 10:49Speaker 1: for eighty kIPS but we need one hundred, the stiffeners
- 10:52Speaker 1: only need to be designed for that extra twenty kIPS.
- 10:55Speaker 2: That's it exactly. For a transverse stiffener, you take your
- 10:58Speaker 2: total factored flange force SUBUF, and you subtract the bare
- 11:02Speaker 2: column's design strength for that limit state. The leftover part
- 11:06Speaker 2: is what your stiffner has to resist. Same idea for
- 11:09Speaker 2: a web doubler plate and shear, you only size it
- 11:12Speaker 2: for the sheer the column web couldn't take on its own.
- 11:15Speaker 1: Let's get into the details for transfer stiffeners. Say we
- 11:18Speaker 1: failed in local flange bending. We need stiffners. What are
- 11:22Speaker 1: the key details for attaching them.
- 11:24Speaker 2: The welding is critical, and it actually depends on whether
- 11:26Speaker 2: the force is tension or compression. If the stiffeners are
- 11:29Speaker 2: for a tensile force pulling the flange out, then the
- 11:32Speaker 2: stiffener must be welded to that column flange to work properly.
- 11:35Speaker 2: But if it's for a compressive force and a low
- 11:37Speaker 2: seismic job, it can either just bear tightly against the
- 11:40Speaker 2: inside of the flange or it can be welded. Steel
- 11:43Speaker 2: is great in bearing, so you have an option there.
- 11:45Speaker 1: That's a really important difference. What about the weld that
- 11:48Speaker 1: connects the stiffener to the column web.
- 11:51Speaker 2: That weld is always required, and it has to be
- 11:54Speaker 2: designed to transfer the unbalanced force from the stifter into
- 11:57Speaker 2: the web's panel zone. And if you have a situation
- 12:00Speaker 2: with reverse curvature bending like from lateral loads, you have
- 12:04Speaker 2: to weld the stiffners to the web to make sure
- 12:07Speaker 2: the shear gets distributed properly along the edge of that
- 12:09Speaker 2: stiffener plate.
- 12:10Speaker 1: Okay, and quickly on doubler plates, once we know how
- 12:13Speaker 1: thick it needs to be for the extra shear, what's
- 12:16Speaker 1: the main thing to watch out for in the shop.
- 12:19Speaker 2: It's the well detail where the plate meets the inside
- 12:21Speaker 2: of the column flange. To get its full sheer capacity,
- 12:24Speaker 2: it has to be welded along those edges. You can
- 12:27Speaker 2: use file at welds or groove welds, and fabricators usually
- 12:30Speaker 2: just pick whichever one uses less weld metal. But here's
- 12:34Speaker 2: the kicker. If you go with a full at weld,
- 12:36Speaker 2: you often have to grind a small bevel on the
- 12:39Speaker 2: edge of the doubler plate just so it can physically
- 12:41Speaker 2: clear the file at radius and the columns k area.
- 12:43Speaker 2: It's a small detail, but it can drive up costs
- 12:46Speaker 2: if you don't plan for it.
- 12:47Speaker 1: That really brings the design requirements right down to the
- 12:50Speaker 1: shop floor.
- 12:51Speaker 2: Okay, finally, let's circle back to that philosophical difference with
- 12:54Speaker 2: high seismic design. We said stiffness governs, not strength. What
- 12:59Speaker 2: is that mean in practice for an engineer.
- 13:01Speaker 1: It means you can't just run those five strength checks
- 13:04Speaker 1: and call it a day. For SMF and IMF systems,
- 13:08Speaker 1: even if your column is huge and it passes all
- 13:10Speaker 1: the elastic strength checks easily. The seismic provisions still normally
- 13:15Speaker 1: require you to put in trans faced stiffeners, so.
- 13:18Speaker 2: Even the biggest column might need stiffeners just for the
- 13:20Speaker 2: stiffness itself.
- 13:21Speaker 1: Absolutely, the goal is often just to limit local deformation
- 13:25Speaker 1: so that the stresses get distributed evenly across the connection.
- 13:28Speaker 1: You want it to behave, Like the connections that were
- 13:30Speaker 1: qualified in all those seclic tests at FEMA, for instance,
- 13:34Speaker 1: a common rule is that the stiffener thickness has to
- 13:37Speaker 1: match the beam blanche thickness.
- 13:39Speaker 2: And the guide has that great example that really drives
- 13:41Speaker 2: this point home.
- 13:42Speaker 1: It does.
- 13:42Speaker 2: It looks at a massive W fourteen by four to
- 13:45Speaker 2: twenty six column with a reduced beam section an RBS
- 13:49Speaker 2: connection in a special moment frame. That column is a beast,
- 13:53Speaker 2: its web is plenty sick for shar but the guide
- 13:56Speaker 2: shows that you still have to put in transverse stiffeners,
- 13:59Speaker 2: not for strength, solely to provide the stiffness and confinement
- 14:02Speaker 2: needed for that connection to behave in a ductile way
- 14:05Speaker 2: when the beam yields during a quake. That difference designing
- 14:08Speaker 2: for controlled failure versus elastic survival is the most important
- 14:12Speaker 2: thing to understand. For seismic work.
- 14:13Speaker 1: That strength versus stiffness distinction is just It's the core
- 14:17Speaker 1: of ductile design and maybe the most critical takeaway for
- 14:20Speaker 1: anyone designing these frames. We've hit the five limit states,
- 14:23Speaker 1: panel zone shear, the surprising economics that favor bigger columns
- 14:27Speaker 1: over fabrication labor, and those non negotiable stiffness rules for
- 14:30Speaker 1: high seismic zones.
- 14:31Speaker 2: I think the ultimate goal of DG thirteen is just efficiency.
- 14:34Speaker 2: Being smart upfront designing a system that minimizes labor, minimizes
- 14:38Speaker 2: risk in that carrier, and maximizes reliability. Every time you
- 14:41Speaker 2: open it, the question should be how can I avoid
- 14:43Speaker 2: this weld?
- 14:43Speaker 1: Excellent? And now for you our listener, a challenge to
- 14:47Speaker 1: tie all these concepts together. Let's say your preliminary design
- 14:50Speaker 1: for a special moment frame in a high seismic area
- 14:53Speaker 1: shows that the column web is highly stressed. Actually, your
- 14:57Speaker 1: PU over p Y ratio is getting clear two point four.
- 15:01Speaker 1: If you check the guide and find that your column
- 15:03Speaker 1: fails both the panel zone web cheer check and the
- 15:06Speaker 1: local flange bending check, how many total required stiffening elements
- 15:10Speaker 1: must you specify? And why might it be more economical
- 15:13Speaker 1: to automatically jump two column sizes up. Rather than specifying
- 15:17Speaker 1: all required reinforcement.
- 15:18Speaker 2: Plates, think about the different elements you'd need to fix
- 15:21Speaker 2: the sheer failure versus the flange bending failure, and the
- 15:23Speaker 2: fabrication labor that comes with each of those solutions.
- 15:26Speaker 1: We'll leave you with that structural puzzle until the next
- 15:28Speaker 1: deep dive. Keep those steel connections strong.