Latest / The Electrical Show / Thomas Nagy and Paul Meenan cover PAT Testing
Transcript
- 0:01The Electrical Show with Thomas Najie sponsored by Bosch Professional Powerful power tools to measuring
- 0:07tools and experts accessories. Welcome to the Electrical Show here on Fix Radio with
- 0:15Bosch Professional on Thomas Najie and with you for the next hour in the studio.
- 0:21Next to me is Paul meena Now we are talking today about PAT testing
- 0:27everyone on site. What pat testing? Yes? Is it treated as a
- 0:32joke and do we actually take it seriously enough? That is what we are
- 0:36going to be talking about today on the show. Now, Paul, he's
- 0:41got his iPad and he's got lots of paper and pens. I've got a
- 0:44feeling he's going to be very vocal on this show, The Electrical Show on
- 0:49Fix Radio. I'm Thomas Nagie with Paul Meenan, and this afternoon we're talking
- 0:54about PAT testing. That first song out the Door actually Queen, it's a
- 0:58kind of magic bizarre. There's actually my absolute favorite Queen's song. I picked
- 1:03up it was a high. It sounds like a silly thing to say that.
- 1:06I actually picked up a runo traffic from Reno, and obviously from Reno
- 1:11they let me borrow it. Shut up producing he's getting a bit gobby here
- 1:14the producer. I picked up a higher van and Reno had they basic gave
- 1:19it to me for free for some sponsorship. And I was driving down the
- 1:22m one and I just turned the radio on. I didn't set it when
- 1:25I literally turned it on, and a kind of magic was playing and some
- 1:29reason, I don't know, that moment stuck in my head and it's not
- 1:30relevant to any of you on site, so I don't know why I said
- 1:33it. So we're going to move on to PAT testing now, Paul pat
- 1:37testing just sharing my life, you know, PAT testing or portable applied testing.
- 1:42There will be some trade he's listening that don't know exactly what it is.
- 1:46So in a nutshell, give us the gravy. Well, welcome to
- 1:49nighttime Naps with Paul and Tom. We're here talking about Paul appliant no so
- 1:55so straight off lefty bunk pat testing. So pat testing. Any electrician here
- 2:00is that word will just go, oh well god, this can be a
- 2:01boring month. So if we look at the IT Code of Practice, which
- 2:05is the fifth edition, now, one of the wonderful things it actually talks
- 2:09about is removing the term PAT testing. We shouldn't we call it PAT testing.
- 2:14In fact, the acronym now is is it, which is the in
- 2:19service inspection and testing of electrical equipment. So yeah, I don't think that's
- 2:23going to catch on. That's that's just doesn't flow off the time, doesn't
- 2:27know, Yeah is it? Is it? Yeah? Yeah, So it's
- 2:30changed now the word PAT testing should be removed from company procedures and policies.
- 2:35It's no longer portable appliance testing. It's well, it's actually portable appliance testing
- 2:39testing testing testing, yes, m yeah, it's basically the effectively for in
- 2:46a nutshell, it was stuff that would move years ago, and over the
- 2:51years, the the definition has been cloudy because if you think of a simple
- 2:54you pull into a service station, we all know fixed yre testing. Um,
- 2:59you know, that's part of the fabric. It goes to a few
- 3:00spur who does the hand rise, who tests and inspects them because they're not
- 3:06portable. So what they've done is they've actually come to realize, yes,
- 3:08there's a gap here. So fixed equipment is now part of what would be
- 3:14portable appliance testing, which is the definition of insanity because it's not portable.
- 3:19Henceforth, in service inspection and testing of electric line. Yeah, E is
- 3:25the acronym. We're just going to call it PAD testing for the rest of
- 3:29this show. That is now clarified. So we're trying to remove the gap
- 3:34because if you think of the amount of equipment electrical equipment out there that the
- 3:38public will handle, there is a gap. And so the IET Code of
- 3:42Practice is trying to encourage people to demark exactly what becomes part of the fixed
- 3:49wire testing on what becomes part of the portable appliance testing, which leads me
- 3:53on to our next question. Who do you think doesn't take it seriously enough?
- 3:57Is it the landlord, the business owner, the electrical contractor. They,
- 4:03I would say a lot of people do. I'll be honest with you.
- 4:05I've done the pat testing, city and guilds, I've managed electrical installations
- 4:11and I have I would be lying if I said I wasn't complacent with it.
- 4:15However, I have known people to get shocks off of stuff, and
- 4:17that's kind of sharpened the pencil and refocus the attitude, especially in modern years
- 4:24where we're importing stuff on Amazon and eBay and we don't really know whether it
- 4:27actually complies with any UK directives. It's more and more and more of it,
- 4:31and Electrical Safety First are doing lots and lots of good work, and
- 4:35the Office of Trading Standards there's lots of product standard websites where you can go
- 4:42and see all the recalls. Even i'd be careful, I haven't checked for
- 4:45ages, but I know and used to be able to go onto the NIC's
- 4:46website and used to type in the name of a contractor. It would bring
- 4:49up whether they were a domestic at stall or an approved contractor. But there
- 4:53was also a pack test tick if they've done the extra bolt on course for
- 4:57pat testing. I don't actually know if that's even still there or not.
- 5:00It was a while ago when I saw that last. But yeah, so
- 5:03there was the Seating Guilds two, three, seven, seven, Parts one
- 5:06and two, which was like the doing of pack testing and the management and
- 5:10oversight of pack testing. I've done. I did both. I'm sure they've
- 5:14probably been replaced now, just shows how rusty I am on it. But
- 5:17yeah, no, there was qualifications and you should have them because when I
- 5:21went and did my training course, I thought it was just a visual inspection
- 5:25and then I realized that actually there's a hell of a lot more to proving
- 5:28the integrity of the equipment. The trouble is is there's no law that says
- 5:33you will pat test. There's multiple laws in for all equipment shelby inspected or
- 5:39maintained. What level is down this is. We're actually going to talk about
- 5:43that in the next link, about how thoroughly this actually, how thoroughly this
- 5:46actually gets done. But what are the main concerns if it's not taken seriously
- 5:50because there are there's a lot of companies which don't I mean there's a lot
- 5:56of people who don't do it right. Okay, without going into law,
- 5:59this kind of a number of activities you can do. So there are the
- 6:01functional checks, so every time you pick a piece of equipment up, you'll
- 6:03always have a look at it and make sure it works, otherwise it won't
- 6:06work. There's then the formal visual inspection without testing and recording of you functional
- 6:13tests of this equipment works, it's got no damage, no breaks. And
- 6:16then there's what we call the combined inspection and testing, where you'll go along
- 6:19and annually or every three months, depending on where it is and what site
- 6:23you're using them. Because on site there are different test requirements than say in
- 6:26an office and the formal inspection and testing to say I have a record of
- 6:30what equipment I'm providing as the employer and what people are using, and I
- 6:34have a robust inspection and test regime sometimes occasionally and I'm sure everybody's got a
- 6:41story where they've heard of an office block where somebody's gone in dunpack testing and
- 6:44blown up half the monitors, or they've tested like six hundred items in a
- 6:46day, or they've done six hundred items in a day, okay, and
- 6:53what was the exact extent of the inspection and test or was it just go
- 6:56and stick, go and stick stickers on and right your initials on. Is
- 7:00is a bit of a problem in the industry. The Electrical Show on fixed
- 7:04radio. This is the Electrical Show. I'm Thomas Nagie with Paul Mean,
- 7:09and if you've just tuned in, we're talking about portable appliance testing otherwise known
- 7:14as testing, and whether it's being taken seriously enough. In this day and
- 7:18age, there are a lot of contractors that it's basically just a visual inspection
- 7:25that looks good, sticker on and six hundred a day later, and your
- 7:30invoice with many thousands of pounds for it. That is rife. What's your
- 7:34take on it? Fundamentally, that isn't a necessarily a bad thing. We're
- 7:41all supposed to be in. The employer is supposed to be in providing us
- 7:44safe workplaces and safe work equipment. We're supposed to treat the equipment well and
- 7:47not use it. I wouldn't want to use a piece of equipment that was
- 7:53damaged. And if somebody gave me a bit of equipment for the first time
- 7:56or whatever, I'd always have a quick look at it. You know,
- 7:59we as electricians are always looking at fred leads, damage plugs and what do
- 8:03you do? You cut it off, you repair it, you do what
- 8:05you need to do. Unfortunately, there is there is parts of the industry
- 8:09to treat it like a joke. There are parts of the industry to go
- 8:11around just putting stickers on and bill in was it one pound and appliance or
- 8:15one pound fifteen appliance? Now you try, Yeah, you try doing an
- 8:20office to say a tower block to ten story tower block, and let's say
- 8:22you've got six thousand appliances there. Now it's going to take ages to pull
- 8:28apart. If it's a full combined inspection and test. You have to pull
- 8:31apart these desks, which can be a labyrinth of extension leads and cables,
- 8:35plus a PC and a monitor and some other bits and bobs. Testing all
- 8:41that. Doing earth continuity, insulation resistance, full inspection and test, you're
- 8:46looking at hours and hours and hours and hours. And I mean I went
- 8:50went out to do an audit on some pack testers that I was employing,
- 8:54and they were like, yeah, we've priced to do it over two nights.
- 8:58And it was an entire office block and it was our head office.
- 9:01And I went out there and I went, right, let's do it properly,
- 9:03had the code of practice. It took us all night to do two
- 9:05bays to take them apart. And the other worst thing is at the end,
- 9:11the guy to Aronny said, I've learned loads. We don't normally do
- 9:13it like this. We just stick a plug on. I won't, but
- 9:16we found so many damaged extension leads, so many hazards, and if we
- 9:20wouldn't have pulled it all apart, we never would have found it, and
- 9:22eventually it would have hurt someone. All start, it's moldering. And that's
- 9:26what scares me, because you sit there and go, how are we even
- 9:28allowing this culture of one pound fifty? Fair enough, it's a visual inspection.
- 9:33But given the way some desks are wired, and you know now that
- 9:35we're doing fixed equipment as well, how much time do you allow on one
- 9:39pound fifty is a limited amount? I mean, yeah, I get it.
- 9:43How do you open up some of these components to get into the terminals
- 9:46to check the terminals if you've never done it before? And there are thousands
- 9:50and thousands of different pieces of equipment, so it's very much risk based everything
- 9:56it regards to maintenance and inspection of portable appliances or fixed u It does seem
- 10:01to be risk based now, and there is requirements in the Electricity at Work
- 10:05Regulation regulation for two for those who want to read it to reflect accurately the
- 10:09legal requirements. We are now going to the whelms of risk assessment. So
- 10:16years ago, there used to be a spreadsheet you could print out from the
- 10:18HSC and it would say three months for everyon site. You know, if
- 10:24you're in an office, you can do twelve months, forty eight months,
- 10:26thirty six months for let's say printers, photocopierses twelve months, So it would
- 10:33give you recommended frequencies, but just be clear they were only ever recommendations.
- 10:37As an employer, you can set wherever recommendation you can. You just need
- 10:41to have a defense in a court of law and say to someone or demonstrate
- 10:45that you've considered the risk of inspecting and testing electrical equipment. So the ITA
- 10:52COP says that a robust risk asession should be carried out in all cases to
- 10:54evaluate the frequency between inspection and testing. This is the responsibility of the due
- 11:00holder for the equipment risk encompas is many factor that can even you influence a
- 11:03final decision. So as a client, I'm an employer, I have a
- 11:07policy because we employ hundreds of people. Once you go above five, you
- 11:11have to start having policies, health and safety policies and all that. And
- 11:15in that you may make a statement that electrical equipment will be regularly inspected and
- 11:18maintained and fit for use. You then have to decide what that frequency is.
- 11:24And if you're doing work on site like you are TOM, then your
- 11:26frequency for checking that. Maybe all my guys are briefed at this start of
- 11:30every shift. Is your equipment fit for purpose? Is it identified, labeled
- 11:33up? Is it in a register. Do we need to do any continuity
- 11:37testing it? Do we need to do this? Do we get someone else
- 11:39in to do it, or do we do it ourselves. Some companies won't
- 11:43do that, even an office. They'll have someone come in every twelve or
- 11:46forty eight months or twenty four months, sorry, and just do a blanket
- 11:50of the whole office. Or you're really to a good point now because a
- 11:52lot of contractors, especially if you're just self employed and stuff, when you
- 11:58actually pick up a PARALLE tool, you'd basically carried out of dynamic risk assessment
- 12:01just when you picked it up and just start. You know, it's kind
- 12:05of like crossing the road. We look both ways. We don't think we're
- 12:07doing it, but we're doing theological contractors, this is easy. For non
- 12:11electrical contractors, this is very difficult. So I went, I went into
- 12:15work, and obviously I work in the railways, and I then said to
- 12:18my colleagues, right, pat testim, we're not supposed to be using the
- 12:20term. It's now is the in service inspection in tests, So I'm not
- 12:24laughingly acronym I know. And everyone saturday and went, can we just use
- 12:30the term PAT testing? I went, yes, of course, but the
- 12:33scope and extent needs to be considered. I was really pleased that they've done
- 12:35this because either them and say, okay, who does the Dyson head hand
- 12:39dryers, Well, that's done part of the fixed warren, isn't it.
- 12:41Noop, Nope, they stopped at the feed to the spur. There's a
- 12:45bit missing, and I think that's the cruxt of it. There's a piece
- 12:48missing. We need to get better at it. My biggest concern is the
- 12:50PAT testers will then potentially be exposing themselves to working on distribution boards doing isolations.
- 12:56Will they be checking the secondary side of a few? There becomes that
- 13:01do we want pat testers venturing into electricians world. It's actually a really good
- 13:05point because they've got to take the fuse but off, so to speak,
- 13:09if they want to test it stuff. And let's be perfect, there are
- 13:11guys out there doing PAT testing who are rocking hot at it but aren't qualified
- 13:16electricians. I actually never stopped thinking about that. That's right. Yeah,
- 13:20if you've got a protesting and they've got to start doing fixed equipment like on
- 13:24a in a train station, toilets, you've got hand rides. And I've
- 13:26met them and they are they are a beautiful creation of God could use that.
- 13:33Are obsessed with the caliber and quality of their pat testing, which is
- 13:37great, but they're not sparks. They're not sparks. So it's there's a
- 13:43health and safety risk there for electrical contractors. No, it's again opportunity.
- 13:46It's a really good point because by rights, I mean should they be taking
- 13:50that few spur off to then we start laying patests as working fuse boards?
- 13:54How do we define It's about defining the demarcation and assessing risks. So you
- 13:58assess the risk, you set your policy, and you define it. For
- 14:01me, I would rather my electricians do all of the testing all the way
- 14:05through to the final product, which I've briefed them on and said, right,
- 14:09if you're doing something and there's a fixed piece of equipment, you're going
- 14:11to do that when you're doing your ICRS, you're going to include the final
- 14:15equipment as well, so that we cover that. You can have a separate
- 14:20PPM regime which goes around plan preventive maintenance that goes around and just inspects these
- 14:24pieces of field equipment. It's made it better, but it's in highlighting the
- 14:28risk. But it's also made it worse because it's less descriptive and to want
- 14:31to shive you. There's so much stuff to do in workplace, as far
- 14:35as compliance and ELpH and safety, you just become tiresome of it. You
- 14:39just want to be told do this, do that, do that. Oh
- 14:41okay, I've got to tick the boxes. It may not be the right
- 14:43attitude, but unfortunately it is a culture that exists out there. For me,
- 14:46I like the risk assessment stuff. As long as you're communicating and being
- 14:50able to say to a judge or an HC inspector, everything is covered by
- 14:54an inspection regime somewhere and here are the records. You're fine, but I
- 14:58would most only recommend you get the fifth edition of the In Service Inspection PAT
- 15:03Testing Book. Fix Radio time to crack on. You're listening to the electrical
- 15:09show with Boss Professional. I'm Thomas Nagi and talking about pat testing. We're
- 15:15with Paul Meena today. Now pat testing, Paul, technically, it isn't
- 15:20actually compulsory, right, wrong, You need to have This is where Paul
- 15:28Meena want to take over the show. I'm going to make a cup of
- 15:30tea. Bye, see later. Okay, So there is a legal obligation
- 15:33to provide a safe work equipment just shut you down. There is a legal
- 15:37obligation to provide a safe work plant, equipment, workplace, etc. And
- 15:43pat testing comes under maintenance. So just to be clear, electricit Work Regulation
- 15:48five is where you would start in the electricit Work. But if you went
- 15:52higher than that, Health and Safety at Work Act Regulations two and three.
- 15:54If you did introduce a piece of electrical equipment and it caused a fatal shock
- 15:58and you were held bank to rights, you'd probably be done under Regulation three
- 16:03of Health and safetyt Work Act. There is duties also under the Management of
- 16:06Health and Safety Work Regulations. I think it's Regulation five Provision and Use of
- 16:10Workplace Equipment also known as pure Workplace Health and Safety Regulations ninety two, the
- 16:15Housing Act, the Housing Act of Scotland and Wales, the Electrical Equipment Safety
- 16:18Regulations two sixteen, Supply Machinery Safety two thousand and eight, Supply Goods Services
- 16:23Act nineteen eighty two, and the Plugs and Sockets Regulations of nineteen ninety four.
- 16:29All of these will be rolled you don't add a few more, no,
- 16:30no, no, All of these will be rolled up and you will
- 16:33be beaten to death by a lawyer or a solicit Yes, the man in
- 16:37a curly wig will try to insert them into you, and you must have
- 16:40a defense. Its maintenance. It doesn't have to be complex. There are
- 16:44many many pieces of legislation out there. And I scaffolder did the best training
- 16:48I've ever been on. And he turned around. He said elf and Safety
- 16:51at Work Act, and we went yeah. And then he listed out loads
- 16:53of other laws and he went, They're all load of rubbish and the only
- 16:56reason they're there is because nobody read the Health and Safety at Work Act.
- 17:00And he had this just brilliant way of talking about health and safety legislation.
- 17:03The fact of matters. You are legally obliged to provide safe workplace and equipment,
- 17:07whether you're an employer or you're an electrical contractor or you're on site.
- 17:10If you don't, and you have no mains regime, whether even it be
- 17:12dynamic assessment and some sort of log that says this is all the equipment I'm
- 17:17bringing onto an Let's just say, let's say we go to the ball builder
- 17:22site. We bring in a load of transformers and load of gear to help
- 17:25them out. We are up all less site tempts. That's wonderful, but
- 17:27we need to have a log of that and make sure it's safe because if
- 17:30one the ball builders gets hurt from normal use and operation, we're done for.
- 17:34And it will be very easy because it's a site and all this legislation
- 17:38will be just used to question us, what did you do? How did
- 17:41you assess the risk to do this? How did you provide safe equipment?
- 17:45Did you do any due diligence? Did you do any visual inspections? Did
- 17:48you any combined tests or inspections? If you haven't done any of that,
- 17:52then you'll get the book front of you to apply to that. That was
- 17:57a very closed That was a very closed sentence. It was a long sentence,
- 18:02But there's no more regulations you want to throw in. That's CDM if
- 18:06you want, If you want to carry on it, sorry, who's actually
- 18:10held accountable because there's it's a duty holder, the duty holder who assesses risk.
- 18:15So you are your duty holder for yourself. If you come to work
- 18:18on my route, technically you're working under me as a duty holder, and
- 18:22I have to make sure that none thing that I provide to you will hurt
- 18:26you or your stuff about inaccurate testing, like the people who just go past
- 18:30past I mean, because I could then turn around, well I've had all
- 18:33my testing done, I've had it all done all nine Yeah, if you've
- 18:37had nine thousand appliances testing, you've got a little sticker on it. That
- 18:41company who's got who's created them and taken the money. They're the ones that
- 18:45are going to be in the doctors is as me as the business owner.
- 18:48I don't get shouted at then, or because do I then do they turn
- 18:53around and say, well did you check and vet that company? Who did
- 18:56that? And this is the worst thing. Now you're probably thinking, what
- 19:00neverhood of anyone ever go into jail for PAT testing anything else? Put it
- 19:03like this, PAT testing is an emot on the day. Yeah, so
- 19:07you can get your car emot emoted and you can drive out no problem.
- 19:10And the day later you have a fatal crash and you go back to the
- 19:12garage. Maybe nothing to doing, just it was a snapshot on that time.
- 19:17They saw a moment on the day that the circumstances changed, and that
- 19:21employee would then be done under Section two or Section three of Health and safety
- 19:25workout because they don't look for PAT test in legislation. They look for other
- 19:30piece of legislation, So landlords electrical safety standards in the private rented Sector Regulations
- 19:33of twenty twenty they came into force, which which requires landlads to be doing
- 19:37pat testing. So who's doing that? How many landlads know they need to
- 19:41be doing it? I don't think, Maddie no, And I mean yeah,
- 19:45it's we're only going to learn the impact of this until somebody gets caught
- 19:49or there's a high profile prosecution. The trouble is is if you go on
- 19:52Google and look at prosecutions and look for EAWR Regulation five, they're always the
- 19:56highest legislation, which is the Health and Safety at work. Look at the
- 20:00minute you're getting paid for something, you're at work, one man band or
- 20:04not. How far do you take this? Yeah? How far? It's
- 20:07dynamic. It's down to you. If if you're an electrical contractor and you're
- 20:11employing skill qualified electrical persons, it's not beyond the realms of impossibility to be
- 20:15able to say you've got some common sense about you. I have a log
- 20:18because one my equipment is valuable. Yeah, I need to know when it
- 20:21was bought, So I've got a record and I can trace it so nobody
- 20:23pinches it. And two before it's before we start our work. The dynamic
- 20:27assessment every day is when you get your tools out, you set up your
- 20:30site, you check all equipment to make sure it's safe, there's no damage,
- 20:33etc. And you record and signed to say yes, I'm good to
- 20:37start now on smaller domestic stuff that probably doesn't happen on commercial industrial sort of
- 20:42sites. You know yourself. If you don't have the RAMS Risk Assessment meta
- 20:45statement and they're all signed up somewhere in there, there will be all equipment
- 20:48will be inspected and tests to have a PAT sticker, there will be a
- 20:51register. If not, you won't be about to start on site. If
- 20:55you're checked. Let's wrap the show up next, as we're running out of
- 20:59time here on fixed radio show. That can we just go and do some
- 21:03on the fixed radio stuff when this show is over Fixed Radio of the Builders
- 21:06stationed the Electrical Show with Thomas Nagie on Fixed Radio the Builders Station. That's
- 21:12it for today's electrical show, where we've talked about PAT testing and whether it
- 21:17should be taken more seriously. And it's a good point you raised earlier in
- 21:21the show that, like any ICR goes up to the few spur and if
- 21:25you've got like a hand or eye bolted on the wall, so the EICR
- 21:27goes up to the spur. But pat testing, if you get a pat
- 21:32tester who's not an electrician which buy rights, they don't have to be,
- 21:36it's a really grey era. I've never ever stopped to think about that.
- 21:37I think of it as an opportunity. How do you stand out from the
- 21:40crowd. You offer that service, You level up your knowledge and say I'm
- 21:45going to do you EICR. But by the way, any fixed equipment,
- 21:47I'm going to include that in my inspection regime for a small premium. But
- 21:52immediately you stand out from the crowd because then the only other stuff that needs
- 21:55to be done is the actual physical portable stuff that helps employers a lot.
- 22:00If you're offer that service, there's a there's a handy tip. Yeah,
- 22:03I actually it sounds really stupid, but I've never thought about that because you
- 22:07don't think you think portum appliances, but stuff that's bolted to the wall isn't
- 22:11part of any ICR. Yeah, it's a weird irony, but just to
- 22:12because the book says it's not necessarily porable down tools with Trevor rich Is moments
- 22:18away, so we're going to have to end it there. You can download
- 22:21This is a podcast from wherever you get them online and make sure you subscribe
- 22:25by the way to get all the new ones as they come out, and
- 22:27you can actually you can subscribe to the Electrical Show newsletter at Fixed Radio dot
- 22:33co dot uk. That will give you access to exclusive content, competitions and
- 22:38news about the industry and you'll also be entered into the draw to win a
- 22:44Maquita site radio. So to be honest, it's worth it just for that.