Latest / Civil Engineering Made Simple / Design Of Concrete Structures
Transcript
- 0:00Speaker 1: Welcome to the deep Dive. Our mission here is simple.
- 0:03Speaker 1: You bring the reading material and we cut straight through
- 0:06Speaker 1: the complexity, giving you the critical actionable knowledge you need.
- 0:10Speaker 2: Right, we're providing that streamline path to expertise.
- 0:12Speaker 1: And today we are focused on well, the cornerstone of
- 0:16Speaker 1: the construction.
- 0:17Speaker 2: World, reinforced concrete structures. Yeah, this deep dive is built
- 0:21Speaker 2: around the essential knowledge in the foundational text design of
- 0:25Speaker 2: concrete structures. Our goal is to give you that comprehensive
- 0:28Speaker 2: practical overview every civil engineer or you know, devanced learner
- 0:33Speaker 2: really needs.
- 0:34Speaker 1: And when we look at the source material, the authority
- 0:36Speaker 1: is just immediately apparent. We're drawing from a lineage that
- 0:39Speaker 1: traces back through giants like Winter and Nilsen.
- 0:43Speaker 2: It's a heavy hitting lineup.
- 0:44Speaker 1: It is I mean, the credentials of one of the
- 0:46Speaker 1: current authors, David Darwin, a licensed professional engineer and ACI
- 0:51Speaker 1: fellow veteran of the US Army Corps of Engineers. It
- 0:54Speaker 1: tells you this isn't just academic theory, not at all.
- 0:56Speaker 2: This is established industry wisdom. It's built on decades of
- 1:00Speaker 2: real world practical application. It's the definitive guide really blending
- 1:05Speaker 2: theory and code.
- 1:06Speaker 1: So at the heart of everything we're discussing is reinforced
- 1:09Speaker 1: concrete or RC.
- 1:11Speaker 2: Right. It's a remarkable composite material. Fundamentally, it's a synergistic
- 1:15Speaker 2: marriage between two seemingly disparate ingredients, concrete and steel.
- 1:21Speaker 1: We know concrete is cheap, it's plentiful, but what does
- 1:24Speaker 1: it bring to that marriage and why is it so
- 1:26Speaker 1: dependent on steel?
- 1:27Speaker 2: Well, concrete is the champion of compression. It's low cost,
- 1:31Speaker 2: it has excellent fire resistance, and because it starts as
- 1:34Speaker 2: a liquid, you can form it into almost any shape. Okay,
- 1:37Speaker 2: but it has one fatal flaw. It has virtually no
- 1:41Speaker 2: usable tensile strength. If you try to pull it apart,
- 1:44Speaker 2: it just fails catastrophically.
- 1:45Speaker 1: And that's where the steel comes in.
- 1:47Speaker 2: That's where we embed steel rods. The steel provides the
- 1:49Speaker 2: high tensile strength, the ductility, and the toughness that concrete
- 1:52Speaker 2: just doesn't have. This union is what allows for the
- 1:55Speaker 2: ubiquity of our sea structures, from bridges and dams to
- 1:58Speaker 2: high rise buildings.
- 2:00Speaker 1: Let's start right there with the foundation, the concrete itself.
- 2:03Speaker 1: The data confirms that Type I normal Portland cement is
- 2:07Speaker 1: the workhorse. It's in over ninety percent of US construction.
- 2:10Speaker 1: So why is this detail about Type I so important
- 2:13Speaker 1: for the timeline?
- 2:15Speaker 2: It really sets the pace of the project. Type I
- 2:18Speaker 2: has a very predictable time curve, so typically we're talking
- 2:21Speaker 2: about one to two weeks for the concrete to gain enough.
- 2:25Speaker 1: Strength before you can strip the forms.
- 2:27Speaker 2: Exactly before the forms supporting that beamer slab can be
- 2:30Speaker 2: safely stripped. That period dictates the whole schedule and critically
- 2:35Speaker 2: the cost of renting all that formwork.
- 2:37Speaker 1: But the industry isn't just sticking to the basics. The
- 2:40Speaker 1: sources highlight this dramatic performance jump we're seeing with high
- 2:43Speaker 1: strength materials.
- 2:44Speaker 2: Oh. Absolutely, we can now get concrete that's four or
- 2:48Speaker 2: five times stronger and steal three or four times stronger
- 2:51Speaker 2: than ordinary materials.
- 2:52Speaker 1: And what does that do for the engineer?
- 2:54Speaker 2: That's where the engineering optimization really begins. The huge practical advantages.
- 2:59Speaker 2: You can reduce the c sections of the structural members.
- 3:01Speaker 1: So smaller columns, smaller beams.
- 3:04Speaker 2: Right, a smaller column means a lighter structure, which reduces
- 3:07Speaker 2: the dead load, and that lets you achieve much longer spans.
- 3:11Speaker 2: It just opens up space and architectural possibility.
- 3:14Speaker 1: And we noted a critical trade off here. While high
- 3:16Speaker 1: strength concrete is a performance upgrade, the text also mentions
- 3:20Speaker 1: it tends to be.
- 3:21Speaker 2: More brittle exactly. That brittleness is something we have to
- 3:25Speaker 2: account for, particularly in seismic design, where we absolutely depend
- 3:29Speaker 2: on ductility, you know, the structure's ability to bend without snapping.
- 3:34Speaker 1: So there's a tension there, a.
- 3:35Speaker 2: Central challenge in modern design, for sure, the tension between
- 3:39Speaker 2: high strength and reliable toughness.
- 3:41Speaker 1: Before we leave materials, the sources offered a fascinating environmental angle.
- 3:46Speaker 1: Producing a cubic yard of concrete generates about two hundred
- 3:50Speaker 1: and fifty pounds of CO two.
- 3:52Speaker 2: Which sounds like a lot.
- 3:53Speaker 1: It does, but the resulting structures provide long term energy benefits.
- 3:57Speaker 2: That's right. The environmental cost of production is offset by
- 4:00Speaker 2: the long term benefit of the building's thermal mass. Concrete's
- 4:04Speaker 2: ability to absorb and slowly release heat means you use
- 4:07Speaker 2: less energy for heating and cooling over the structured service life,
- 4:11Speaker 2: which can be decades.
- 4:12Speaker 1: Okay, let's move to defining the properties we actually use
- 4:14Speaker 1: in the calculations. Specified compressive strength that's f prime C
- 4:19Speaker 1: is the baseline. We also need the modulus of elasticity
- 4:23Speaker 1: E subc the stiffness. What's the quick takeaway on calculating that?
- 4:28Speaker 2: The key takeaway is that for standard normal weight concrete,
- 4:32Speaker 2: the stiffness isn't a constant, it's proportional to the square
- 4:36Speaker 2: root of its compressive strength. This gives us that common
- 4:39Speaker 2: simplified relationship where E subc is approximately fifty seven thousand
- 4:44Speaker 2: times the square root of f prime c in CSI.
- 4:47Speaker 1: But there's a catch.
- 4:48Speaker 2: There is. The important nuance here is that for high
- 4:51Speaker 2: strength concrete, that equation often starts to overestimate the actual stiffness,
- 4:55Speaker 2: so you might need more refined testing.
- 4:57Speaker 1: Okay, let's talk theory, because the entire DOES design framework
- 5:01Speaker 1: hinges on a couple of foundational assumptions about how this
- 5:03Speaker 1: material behaves. What are those two critical ones?
- 5:06Speaker 2: The first is simple plane sections remain plain during bending.
- 5:09Speaker 2: This basically dictates that the strained distribution across the member
- 5:12Speaker 2: is linear. In the second one, the second, which is
- 5:15Speaker 2: maybe the most profound simplification in RC design, is the
- 5:18Speaker 2: assumption that concrete resists no tension, stresses, whatever.
- 5:22Speaker 1: But wait, concrete does resist some tension before it cracks,
- 5:26Speaker 1: So why do we just completely ignore that?
- 5:27Speaker 2: We ignore it because we want a single reliable model.
- 5:31Speaker 2: By assuming the steel carries all the tension, we simplify
- 5:35Speaker 2: the complex nonlinear behavior of concrete into a workable formula.
- 5:40Speaker 1: Ah like the rectangular stress block exactly.
- 5:44Speaker 2: That famous method allows engineers to calculate the ultimate flexual
- 5:47Speaker 2: capacity predictably. This simplification really forms the entire theoretical basis
- 5:53Speaker 2: for the ultimate strength design method we use today.
- 5:55Speaker 1: And before we move on, we have to touch on
- 5:57Speaker 1: its high performing sibling, dressed concrete.
- 6:01Speaker 2: Pre Stressed concrete is a specialized beast. We use very
- 6:04Speaker 2: high strength steel which is tensioned or jacked against the
- 6:07Speaker 2: concrete before service loads are even applied.
- 6:10Speaker 1: So you're squeezing the concrete on purpose.
- 6:12Speaker 2: You're putting it into pre compression. Yeah, this induces a counterload,
- 6:16Speaker 2: creating these internal compressive stresses that significantly delay cracking, dramatically
- 6:21Speaker 2: reduced deflections, and let us achieve much longer spans and
- 6:24Speaker 2: smaller cross sections.
- 6:26Speaker 1: Okay, now that we understand the material, let's look at
- 6:28Speaker 1: how we use it. This takes us to the three
- 6:31Speaker 1: distinct stages of flexual analysis for a beam. Walk us
- 6:34Speaker 1: through that.
- 6:35Speaker 2: Sure stage one is low loads. Stresses are small. The
- 6:38Speaker 2: concrete hasn't cracked yet, The entire section is effective and
- 6:42Speaker 2: it all behaves elastically.
- 6:44Speaker 1: Stage two is the AHA moment for students. The cracked section.
- 6:48Speaker 2: Exactly once the applied tensile stress exceeds the concrete's modulus
- 6:52Speaker 2: of rupture, cracks form in the tension zone. The analysis
- 6:56Speaker 2: immediately throws out the cracked concrete below the new neutral axis.
- 7:00Speaker 1: So you just assume it's gone.
- 7:01Speaker 2: We assume it's carrying zero load. All the tension is
- 7:04Speaker 2: now carried by the steel, and this causes the neutral
- 7:07Speaker 2: axis to shift upward. Closer to the compression phase is
- 7:10Speaker 2: the effective working area shrinks.
- 7:12Speaker 1: So we're knowingly designing structures that will crack under normal loads.
- 7:15Speaker 1: How do you square that with safety?
- 7:17Speaker 2: Well, we rely on the ductile steel to safely carry
- 7:20Speaker 2: those tension loads. The cracking is expected, it's controlled.
- 7:24Speaker 1: And that leads to stage three.
- 7:26Speaker 2: Stage three is the ultimate strength stage. Failures predicted when
- 7:30Speaker 2: the concrete at the compression phase reaches its maximum usable strain,
- 7:34Speaker 2: which is typically about point zero zero three. We confirm
- 7:38Speaker 2: the steel has yielded, and then we calculate the maximum
- 7:41Speaker 2: moment based on the resulting tension force. This model very
- 7:44Speaker 2: accurately predicts the member's capacity.
- 7:46Speaker 1: Let's get practical. Cover requirements are huge for durability and
- 7:50Speaker 1: fire protection. Why the massive difference between say, a slab
- 7:54Speaker 1: and a footing.
- 7:55Speaker 2: It all comes down to exposure. Interior slabs only need
- 7:59Speaker 2: about three quarters of an inch of clear cover, mostly
- 8:02Speaker 2: for fire rating. Beams being larger, need one and a
- 8:05Speaker 2: half inches. But footings, which are in direct contact with
- 8:08Speaker 2: aggressive environments soil, moisture or chemicals, they need at least
- 8:12Speaker 2: three inches of cover to prevent corrosion that could threaten
- 8:15Speaker 2: the whole structure.
- 8:16Speaker 1: And on the construction side, the sources remind us that
- 8:18Speaker 1: overall beam dimensions BNH are almost always rounded up.
- 8:22Speaker 2: It's a simple point, but essential for constructibility. I mean,
- 8:25Speaker 2: form work is built using simple measurements. Complex fractional dimensions
- 8:29Speaker 2: just slow down the crew and increase cost.
- 8:31Speaker 1: Now, when a slab and beam act together we get
- 8:34Speaker 1: a T beam. How do we determine how much of
- 8:37Speaker 1: that slab is actually helping the beam?
- 8:39Speaker 2: We use what's called the effective flange with B subf.
- 8:43Speaker 2: The code limits this to prevent us from assuming the
- 8:46Speaker 2: entire slab acts as a huge flange.
- 8:48Speaker 1: And how does that affect the math well.
- 8:51Speaker 2: The location of the neutral axis then dictates the analysis.
- 8:54Speaker 2: If the axis is within the flange, it's analyzed as
- 8:57Speaker 2: a simple rectangle. If the axis drops in the web,
- 9:00Speaker 2: the calculation for the compression area becomes more complex. You
- 9:03Speaker 2: have to account for the stem and the flange separately.
- 9:06Speaker 1: Moving from strength to serviceability, deflection and crack control. Calculating
- 9:10Speaker 1: deflection is mandatory for pre stressed members, But what's the
- 9:13Speaker 1: key insight for long term deflections? In ordinary RC?
- 9:17Speaker 2: The insight is that long term deflection which is largely driven.
- 9:20Speaker 1: By creep, which is the concrete deforming under a constant load.
- 9:24Speaker 2: Exactly continuous deformation under sustained load that can be significantly
- 9:28Speaker 2: reduced by placing reinforcement on the compression side. This compression
- 9:32Speaker 2: steel reduces the creep deformation, mitigating those long term sagging
- 9:36Speaker 2: issues and for crack control. For crack control, we limit
- 9:40Speaker 2: the maximum spacing of the tension bars. It's based on
- 9:43Speaker 2: the clear cover and the calculated steel stress under expected
- 9:46Speaker 2: service conditions, just to keep those cracks tight and less noticeable.
- 9:50Speaker 1: Bending is usually the first thing we check, but sheer
- 9:53Speaker 1: forces can be just as critical and often more dangerous.
- 9:57Speaker 1: Why are engineers so fearful of sheer.
- 9:59Speaker 2: Failure because sheer failure, which is initiated by diagonal tension cracking,
- 10:04Speaker 2: is inherently brittle and sudden. It happens at a pretty
- 10:07Speaker 2: low shear stress too, so.
- 10:09Speaker 1: It gives no warning, almost none.
- 10:11Speaker 2: So to prevent this abrupt collapse and ensure the member
- 10:13Speaker 2: can actually reach its full flectual capacity, web reinforcement those
- 10:18Speaker 2: U shaped stirrups is mandatory in almost all beams.
- 10:21Speaker 1: Here's where it gets really interesting. Torsion. Oh yeah, we're
- 10:24Speaker 1: not talking about simple twisting. We're talking about two fundamentally
- 10:27Speaker 1: different types of torsion exactly.
- 10:29Speaker 2: We differentiate between equilibrium torsion and compatibility torsion. Equilibrium torsion
- 10:33Speaker 2: is non negotiable. It's required by static equilibrium. Think of
- 10:38Speaker 2: the twisting force on a beam supporting a candilabored balcony.
- 10:41Speaker 1: If you ignore it, it falls down.
- 10:43Speaker 2: The structure will fail. Compatibility torsion, though, that arises from
- 10:47Speaker 2: the continuity of members in a statically indeterminate frame. The
- 10:51Speaker 2: frame just needs to maintain alignment, and.
- 10:53Speaker 1: The reinforcement reflects that difference.
- 10:56Speaker 2: Right absolutely does. Torsion requires closed stirrups. The the U
- 11:00Speaker 2: shaped bars we use for shar just won't work because
- 11:03Speaker 2: torsional stresses acts on all four faces of the member.
- 11:06Speaker 2: You need a closed loop to contain that tension.
- 11:09Speaker 1: Let's pivot to how force gets into the steel itself,
- 11:13Speaker 1: anchorage and development length L SUBD.
- 11:16Speaker 2: Think of L subd as the required grip strength. The
- 11:19Speaker 2: steel rebar has to be embedded deep enough into the
- 11:22Speaker 2: concrete to develop its full yield strength before the bar ends.
- 11:26Speaker 1: If it's too short.
- 11:27Speaker 2: If L subd is too short, the bar just slips
- 11:29Speaker 2: out and the structure fails. We have precise calculations for
- 11:32Speaker 2: it based on cover and spacing, or we can use
- 11:34Speaker 2: simplified code tables.
- 11:35Speaker 1: What if you just run out of room for that
- 11:37Speaker 1: straight bar.
- 11:37Speaker 2: That's where special anchorage comes in. We use ninety degree
- 11:41Speaker 2: or one hundred eighty degree hooks or increasingly headed bars,
- 11:45Speaker 2: which provide mechanical anchorage. They essentially bypass the need for
- 11:49Speaker 2: a long straight development length by locking the bar into
- 11:52Speaker 2: the compression zone.
- 11:54Speaker 1: Finally, let's analyze columns. They're rarely under pure axial love.
- 11:58Speaker 1: There's always some bending. How does the failure mode shift
- 12:01Speaker 1: depending on where that load is?
- 12:03Speaker 2: For short columns, the load's position. The eccentricity is key.
- 12:07Speaker 2: If the load is very close to the center, the
- 12:09Speaker 2: entire section is in compression and failure is brittle the
- 12:13Speaker 2: concrete crushes.
- 12:14Speaker 1: And if the load is far out.
- 12:15Speaker 2: If the load moves far out, the bending dominates and
- 12:18Speaker 2: failure is initiated by the tension steel yielding, which is
- 12:21Speaker 2: a much more ductial failure.
- 12:22Speaker 1: And this relationship is all summarized by the interaction diagram.
- 12:26Speaker 2: That diagram is the designer's roadmap. It shows every combination
- 12:29Speaker 2: of axial load and bending moment the section can safely resist.
- 12:33Speaker 1: And what about when a corner column is bending about
- 12:35Speaker 1: both axes by axial bending.
- 12:37Speaker 2: For that, we often use approximate methods like the reciprocal
- 12:41Speaker 2: load method, but it's crucial to remember that this approximation
- 12:45Speaker 2: is only reliably accurate for design when the axial load
- 12:48Speaker 2: is greater than ten percent of the concentric capacity. If
- 12:52Speaker 2: your column is dominated by bending, that method loses accuracy.
- 12:56Speaker 1: Fast and we have to mention slender columns where the
- 12:59Speaker 1: length just complicates everything.
- 13:01Speaker 2: Slender columns are those where strength is significantly reduced because
- 13:05Speaker 2: of lateral deflection when the column bends the axial load
- 13:10Speaker 2: acting on That deflection creates an additional secondary moment. We
- 13:13Speaker 2: call it the p delta.
- 13:14Speaker 1: Effect, So you have to account for that.
- 13:16Speaker 2: You do. Designing these requires calculating a moment magnification factor
- 13:20Speaker 2: to accurately account for this effect.
- 13:22Speaker 1: Okay, moving to floor systems. Two A. Slabs supported on
- 13:26Speaker 1: all four sides are very efficient, especially flat plate slabs
- 13:30Speaker 1: poured without any beams or capitals.
- 13:32Speaker 2: Right.
- 13:32Speaker 1: What's the achilles heel of a flat plate system punching sheer?
- 13:36Speaker 2: This is often the governing factor for the slab's thickness.
- 13:39Speaker 2: The column literally attempts to punch right through the slab.
- 13:41Speaker 1: And there's a specific place you check for that.
- 13:43Speaker 2: Yep, the critical failure surface is checked around the column
- 13:46Speaker 2: face at a distance of d over two. If the
- 13:49Speaker 2: concrete alone can't handle it, we have to provide localized
- 13:53Speaker 2: sheer reinforcement like stirps or specialized shearheads right around that
- 13:57Speaker 2: column perimeter.
- 13:58Speaker 1: Circling back to pre stress, let's elaborate on losses. The
- 14:02Speaker 1: effect of stressing force is always less than what you
- 14:05Speaker 1: put in initially always. Can you categorize the types of
- 14:09Speaker 1: losses for us?
- 14:10Speaker 2: Certainly, they fall into two main categories instantaneous and time dependent.
- 14:15Speaker 2: Instantaneous losses happen right away when you're tensioning, friction from
- 14:19Speaker 2: the tendon curving or wobbling, anchorage slip, and the elastic
- 14:23Speaker 2: shortening of the concrete itself when the force is transferred, and.
- 14:25Speaker 1: The time dependent ones. Those sound more complex.
- 14:28Speaker 2: They are. They're the most tedious to calculate because they're
- 14:30Speaker 2: cumulative and happen over years. These include concrete creep, concrete shrinkage,
- 14:35Speaker 2: and the relaxation of the high strengths steel itself.
- 14:38Speaker 1: So the effective force is what's left over.
- 14:40Speaker 2: It's what remains after you account for all of those losses.
- 14:44Speaker 2: And for pretension strand we talk about total development length.
- 14:47Speaker 2: That's the sum of the initial transfer length plus the
- 14:50Speaker 2: length needed to ramp the stress up to its ultimate value.
- 14:53Speaker 1: Finally, let's discuss the gold standard of safety a seismic design.
- 14:57Speaker 1: It's all about ductility, maximum ductility. If a structure is
- 15:02Speaker 1: in a high seismic hazard category, what specialized philosophy dictates
- 15:06Speaker 1: the design.
- 15:07Speaker 2: We must employ capacity design and detail the structure as
- 15:11Speaker 2: a special mode frame. The core philosophy is well, it's simple,
- 15:15Speaker 2: force the structure to fail in the way we want
- 15:17Speaker 2: it to, which is, we want ductile, predictable flexual failure
- 15:21Speaker 2: in the beams, not brittle shear failure in the joints
- 15:23Speaker 2: or columns.
- 15:24Speaker 1: So you're intentionally over designing certain elements.
- 15:27Speaker 2: Precisely, we impose specific geometric constraints on beams, like a
- 15:31Speaker 2: minimum clear span of four times the effective depth and
- 15:34Speaker 2: a minimum fidth of ten inches to ensure flexual failure dominates.
- 15:38Speaker 2: And crucially, the shear design is governed by the seismic
- 15:40Speaker 2: shear force.
- 15:41Speaker 1: Vsub which is calculated using the probable moment strength.
- 15:44Speaker 2: Exactly m subpri.
- 15:45Speaker 1: Explain that concept M subpr based on one point two
- 15:49Speaker 1: five times f sub y Why one in a quarter
- 15:52Speaker 1: times the nominal yield strength, because.
- 15:54Speaker 2: We know that steel rarely yields exactly at its specified
- 15:59Speaker 2: nominal strength. It often yields higher, and when it strain hardens,
- 16:03Speaker 2: it can develop forces even twenty five percent greater than
- 16:06Speaker 2: F sub y.
- 16:07Speaker 1: Ah, So you're designing for the worst case real world strength.
- 16:10Speaker 2: By using one point two five f subwy, we are
- 16:13Speaker 2: ensuring that we calculate the maximum possible sheer force the
- 16:16Speaker 2: beam can ever generate when it forms a plastic hinge.
- 16:20Speaker 2: We then design the connecting joint and the column to
- 16:23Speaker 2: safely handle that maximum actual force, guaranteeing that the joint
- 16:27Speaker 2: is stronger than the beam. That is capacity design and action.
- 16:30Speaker 1: That progression from defining the basic strength of concrete to
- 16:33Speaker 1: calculating these complex load paths under seismic conditions. It just
- 16:37Speaker 1: shows how foundational material properties govern every single design decision.
- 16:41Speaker 2: Right, You're layering complexity onto these simple fundamentals.
- 16:44Speaker 1: So what does this all mean for the learner understanding
- 16:47Speaker 1: this level of detail? Why type is cement dictates the schedule,
- 16:51Speaker 1: the nuance between equilibrium and compatibility, torsion, and that critical
- 16:55Speaker 1: role of one point two five f sub y is
- 16:58Speaker 1: what separates a code follower from professional engineer.
- 17:01Speaker 2: It is it's what allows you to design safe, serviceable,
- 17:04Speaker 2: and economical structures. Lets you anticipate structural behavior and apply
- 17:07Speaker 2: true professional judgment rather than just relying on prepackaged software.
- 17:12Speaker 1: Results to reinforce that concept. Here's a question for you
- 17:15Speaker 1: to consider. Assume our rectangular column has a concentric load
- 17:18Speaker 1: capacity P sub zero of one thousand kIPS, It is
- 17:22Speaker 1: subjected to an axial load P s abent of sixty
- 17:25Speaker 1: kIPS and biaxial bending based on the source material's guidance
- 17:29Speaker 1: regarding the approximate reciprocal load method. Would this method be
- 17:33Speaker 1: considered reliable for checking the design adequacy of this column?
- 17:37Speaker 2: And finally, a provocative thought to mull over, if we
- 17:40Speaker 2: acknowledge the tension that high strength concrete is generally more brittle,
- 17:44Speaker 2: and yet modern design pushes towards smaller member cross sections
- 17:47Speaker 2: using these materials, what long term changes might be necessary
- 17:51Speaker 2: in our design philosophy to maintain the core assumption of
- 17:54Speaker 2: structural ductility and failure mode behavior, especially in seismic zones
- 17:58Speaker 2: where that toughness is paramount. That structural paradox is where
- 18:02Speaker 2: the next generation of concrete research will surely focus