Latest / Civil Engineering Made Simple / High Strength Bolts: A Primer for Structural Engineers
Transcript
- 0:00Speaker 1: We're jumping right into the guts of structural engineering today.
- 0:03Speaker 1: Our mission is to take the American Institute of Steel
- 0:07Speaker 1: Constructions guide on high strength bolts and really turn into
- 0:12Speaker 1: a clear roadmap.
- 0:13Speaker 2: Yeah, for anyone learning steel design or for young engineers
- 0:16Speaker 2: out on a job site, this is.
- 0:18Speaker 1: Your essential deep dive into the engineering physics and the
- 0:21Speaker 1: LRFD principles for bolted connections.
- 0:24Speaker 2: It's absolutely foundational knowledge. I mean, whether you're sizing a
- 0:26Speaker 2: connection or checking it on site, you have to understand
- 0:30Speaker 2: how these things transfer force and why the installation method
- 0:33Speaker 2: is so critical.
- 0:34Speaker 1: And we can't really skip the history, can we. It
- 0:36Speaker 1: sets the whole stage. I mean, until the nineteen fifties,
- 0:39Speaker 1: it was all hot rivets.
- 0:40Speaker 2: Oh exactly, the old A five O twos. It was
- 0:42Speaker 2: labor intensive, often inconsistent, and the big thing was you
- 0:46Speaker 2: had a completely uncertain clamping force.
- 0:48Speaker 1: You just didn't know, you didn't know.
- 0:50Speaker 2: The shift to high strength bolts was well, it was
- 0:52Speaker 2: a revolution. It gave us controlled, verifiable tension. Suddenly you
- 0:57Speaker 2: could install a fastener and know the force it was providing.
- 1:00Speaker 1: Which brings us to classification. Because there's a real hierarchy here.
- 1:03Speaker 2: There is at the bottom you've got your common bolts,
- 1:05Speaker 2: your AsTMa three oh seven's minimum tensile strength of what
- 1:10Speaker 2: sixty k si? Right, they're fine for static stuff, but
- 1:13Speaker 2: they're only installed snug type. The preload is low and
- 1:17Speaker 2: again totally uncertain.
- 1:19Speaker 1: Then you get to the serious structural stuff.
- 1:22Speaker 2: The workhorse A three twenty five bolts typically around one
- 1:26Speaker 2: hundred and twenty k si, and then the top tier
- 1:28Speaker 2: A four nineties, which are up at one hundred and
- 1:31Speaker 2: fifty k si.
- 1:32Speaker 1: And these are the ones that fall under the RCSSE,
- 1:34Speaker 1: the Research Council on Structural Connections.
- 1:36Speaker 2: Exactly, and that's key for these bolts. Controlled pre load
- 1:40Speaker 2: isn't just a nice to have, it's a structural necessity.
- 1:43Speaker 1: Okay, let's quickly lay out how we categorize connections based
- 1:46Speaker 1: on the load.
- 1:47Speaker 2: You can break it down by the force on the fastener.
- 1:49Speaker 2: So it's either sheer tension or a combination of the two.
- 1:52Speaker 1: And a classic sheer example would.
- 1:53Speaker 2: Be a double lap splice. You're pulling plates in opposite
- 1:56Speaker 2: directions trying to slice right through the bolt. The force
- 1:59Speaker 2: gets trans forred by the bolt shearing and the plate
- 2:01Speaker 2: bearing against the hole.
- 2:02Speaker 1: Pure tension.
- 2:03Speaker 2: Just picture a hangar hanging off the bottom of a
- 2:05Speaker 2: beam flange. The load is pulling straight down, putting the
- 2:09Speaker 2: bolt right into tension.
- 2:10Speaker 1: Right, And the real world is mostly some combination of
- 2:14Speaker 1: the two.
- 2:14Speaker 2: Most of the time. Yeah, But the main takeaway here
- 2:17Speaker 2: for anyone listening is you have to understand the flow
- 2:20Speaker 2: of forces. You need to be able to see it
- 2:22Speaker 2: with free body diagrams and trace how that load moves
- 2:27Speaker 2: through the plates and into the bolts.
- 2:29Speaker 1: Let's move to probably the most critical distinction and a
- 2:32Speaker 1: construction site, the installation state. We've said snug tight, and
- 2:36Speaker 1: then there's pretension. Why is this so important?
- 2:39Speaker 2: Well, snug tight is the baseline. It's what an iron
- 2:42Speaker 2: worker gets with the full effort of a spud wrench
- 2:45Speaker 2: or maybe the first few hits of an impact gun.
- 2:48Speaker 2: So it pulls the plates together, It pulls them compactly together. Yes,
- 2:51Speaker 2: but the internal force that preload is unreliable. It's fine
- 2:55Speaker 2: for a lot of standard building connections, you know static
- 2:57Speaker 2: gravity loads.
- 2:58Speaker 1: But when does the code force you to step up
- 3:00Speaker 1: to that fully pretentioned state.
- 3:02Speaker 2: You have to pretention when a connection is designated slip
- 3:05Speaker 2: critical so zero movement allowed, or if it sees load reversal,
- 3:10Speaker 2: serious vibrations, fatigue.
- 3:13Speaker 1: And pretensioning means hitting a specific.
- 3:15Speaker 2: Target, a very specific target. The RCSC specifies it as
- 3:19Speaker 2: seventy percent of the bolt's minimum ultimate tensile strength.
- 3:22Speaker 1: That seventy percent is the magic number, so guaranteeing you
- 3:26Speaker 1: hit that on site where friction can be all over
- 3:29Speaker 1: the place. That seems like the real challenge.
- 3:31Speaker 2: It is, and that's where the different methods come in
- 3:33Speaker 2: the gold standard. The most reliable is the turn of
- 3:35Speaker 2: nut method.
- 3:36Speaker 1: Okay, unpack that for us. How does just stretching a
- 3:40Speaker 1: bolt a certain amount get around all the problems with friction?
- 3:43Speaker 2: It's brilliant because it's based on elongation, not torque. Once
- 3:47Speaker 2: you're snug prit you turn the nut a prescribed amount,
- 3:49Speaker 2: like a half turn, you are physically stretching that bolt
- 3:52Speaker 2: well into its inelastic range.
- 3:54Speaker 1: You're deforming it permanently.
- 3:55Speaker 2: A little bit, yes, And because you're forcing a specific
- 3:58Speaker 2: large deformation, the final tension is incredibly consistent and always
- 4:02Speaker 2: well above that seventy percent minimum. It almost doesn't matter
- 4:05Speaker 2: what the initial snuck type condition was, so.
- 4:07Speaker 1: It's basically structural insurance against friction. But you still see
- 4:12Speaker 1: torque control used. Why is the calibrated wrench method still around.
- 4:16Speaker 2: Speed mostly, but it is risky. With a calibrated wrench,
- 4:21Speaker 2: you're controlling friction. You use a power wrench that's been
- 4:24Speaker 2: calibrated that day on a skidmore Ville helm device.
- 4:27Speaker 1: Little hydraulic load cell, right, and it's.
- 4:30Speaker 2: Set to stall at a torque that gives you the
- 4:32Speaker 2: right preload. But if you miss that daily calibration or
- 4:35Speaker 2: it starts to rain and the lubrication changes, your preload
- 4:38Speaker 2: could be way off.
- 4:39Speaker 1: And because it's all about friction, you have to use
- 4:42Speaker 1: hardened washers under whatever you're turning.
- 4:44Speaker 2: You must to standardize that friction surface.
- 4:47Speaker 1: And the worst case isn't just a loose bolt, it's
- 4:49Speaker 1: a slip critical joint that moves under service loads because
- 4:54Speaker 1: it never had the required clamping force precisely.
- 4:57Speaker 2: Then you have the specialized bolts, like tension control bolts.
- 5:00Speaker 1: The ones with the little spline on the end that
- 5:02Speaker 1: snaps off.
- 5:02Speaker 2: Yeah, the f eighteen fifty twos. They're great because you
- 5:05Speaker 2: can install them from one side, but you know it's
- 5:07Speaker 2: still a torque mechanism that shares the spline, so they
- 5:10Speaker 2: need the same daily pre installation check as a calibrated wrench.
- 5:13Speaker 1: And my favorite for just pure verification, the direct tension
- 5:17Speaker 1: indicators the DTIs.
- 5:20Speaker 2: DTIs are an elegant solution. I think they're basically special
- 5:23Speaker 2: washers with little bumps on them. As you tighten the bolt,
- 5:26Speaker 2: the bumps compress. You check the pretension by sticking a
- 5:29Speaker 2: feeler gauge in the gap. It's a direct measure of compression,
- 5:33Speaker 2: so it's not dependent on torque at all.
- 5:34Speaker 1: Much more reliable, much more okay, bolter en. Let's talk
- 5:37Speaker 1: about how they actually fail. We have to draw a
- 5:40Speaker 1: really clear line between serviceability the slip critical joint and
- 5:44Speaker 1: ultimate strength, which is the bearing type joint.
- 5:47Speaker 2: A slip critical joint is all about serviceability. Its only
- 5:51Speaker 2: job is to prevent any movement between the plates period.
- 5:54Speaker 1: So all of its resistance comes from friction. It's totally
- 5:57Speaker 1: dependent on that clamping force from.
- 5:59Speaker 2: The PRETENTI The resistance is just the bolt pretension times
- 6:03Speaker 2: the slip coefficient. If the load exceeds that friction, the
- 6:07Speaker 2: joint slips and it has failed its serviceability limits state.
- 6:11Speaker 1: And the moment it slips it becomes a bearing type joint.
- 6:14Speaker 1: That's right.
- 6:14Speaker 2: Now, it's relying on the bolt shank physically bearing against
- 6:17Speaker 2: the side of the whole. It's designed for the maximum
- 6:20Speaker 2: ultimate load, and.
- 6:21Speaker 1: Its capacity is governed by one of two things happening. Correct.
- 6:24Speaker 2: First is bolt sheer capacity, where the bolt itself just
- 6:27Speaker 2: shears in half. And here's that critical point again, the
- 6:31Speaker 2: ultimate sheer strength of a bolt is completely unaffected by
- 6:35Speaker 2: its initial pretension.
- 6:37Speaker 1: It feels so counterintuitive. We spent all this effort putting,
- 6:40Speaker 1: you know, seventy percent of its ultimate strength into it
- 6:43Speaker 1: as tension. How does that just disappear at the moment
- 6:46Speaker 1: of sheer.
- 6:46Speaker 2: Failure because the sheer deformation is just it's massive compared
- 6:51Speaker 2: to the tiny bit of elongation from the pretension. As
- 6:54Speaker 2: the bolt deforms in shear, that tensile stress is effectively released.
- 6:58Speaker 2: By the time it actually fails and sheer, the initial
- 7:00Speaker 2: preload is gone.
- 7:01Speaker 1: That clears up so much confusion. Now, in the LRFD formula,
- 7:05Speaker 1: the sheer strength is taken as zero point five times
- 7:07Speaker 1: the ten style strength, but testing shows it's closer to
- 7:10Speaker 1: point six to two. Why the twenty percent haircut.
- 7:13Speaker 2: That's a great example of practical design simplification. That reduction
- 7:16Speaker 2: from er point six to two down to point five
- 7:18Speaker 2: zero accounts for the joint length effect, meaning in a
- 7:22Speaker 2: real joint with a line of bolts, the volts always
- 7:25Speaker 2: take more than their fair share of the load. The
- 7:27Speaker 2: LRFD just bakes a twenty percent reduction right into the
- 7:30Speaker 2: formula to account for that uneven stress even for short joints.
- 7:34Speaker 2: It's a built in safety.
- 7:35Speaker 1: Factor, got it. And the second failure mode for bearing
- 7:39Speaker 1: is the plate itself.
- 7:40Speaker 2: Failing right the connected material bearing capacity. The bolt is
- 7:43Speaker 2: pushing so hard on the whole that the plate material
- 7:46Speaker 2: either yields too much or a chunk of it just
- 7:48Speaker 2: shears out. The resistance there depends on the plate thickness,
- 7:52Speaker 2: its strength, and the geometry you know, the edge distances.
- 7:55Speaker 1: Speaking of geometry, let's talk about sheer leg.
- 7:57Speaker 2: Sheer leg happens when you connect a member like an angle,
- 8:01Speaker 2: by only one of its legs. The force isn't flowing
- 8:04Speaker 2: through the entire cross section uniformly.
- 8:06Speaker 1: So the whole member isn't working efficiently.
- 8:08Speaker 2: Exactly the unconnected part well it lags behind. To account
- 8:12Speaker 2: for this, LRFD makes you reduce the net area to
- 8:15Speaker 2: what it calls an effective net area. You multiply by
- 8:18Speaker 2: a factor U which you can calculate or for simplicity,
- 8:21Speaker 2: just use standard values from the spec like ero point
- 8:24Speaker 2: seventy five.
- 8:24Speaker 1: Okay, last failure mode in this category block sheer. This
- 8:29Speaker 1: one sounds dramatic.
- 8:30Speaker 2: It is. It's when a whole block of material tears
- 8:33Speaker 2: right out of the end of the connection. It's a
- 8:35Speaker 2: combined failure. You get sheer failure along the line of
- 8:38Speaker 2: bolts and at the same time tension failure across the block.
- 8:42Speaker 1: And the lrfdspec gives us a couple of equations to
- 8:44Speaker 1: check for that.
- 8:45Speaker 2: Yes, you check two potential paths. The AISE Guide authors
- 8:49Speaker 2: often suggest that for things like gusset plates or coped beams,
- 8:54Speaker 2: the path of net tension fracture combined with gross sheer
- 8:56Speaker 2: yields tends to be the more realistic predictor of what
- 8:59Speaker 2: actually happens.
- 9:00Speaker 1: Let's switch gears to bolt's intension. If we have a
- 9:04Speaker 1: fully pretension bolt and we start pulling on it, how
- 9:07Speaker 1: does the force in the bolt change?
- 9:10Speaker 2: This is another one that bends your brain a bit.
- 9:12Speaker 2: As you apply external tension, the force in the bolt
- 9:14Speaker 2: itself barely increases, maybe five or ten percent. Why is
- 9:18Speaker 2: that because the connected plates are still clamped together in
- 9:20Speaker 2: compression and they are incredibly stiff. They're actually carrying most
- 9:24Speaker 2: of that external load.
- 9:25Speaker 1: They're acting like a really, really stiff.
- 9:27Speaker 2: Spring, a very stiff spring, exactly. But the second the
- 9:30Speaker 2: external load is bigger than the clamping force, the plates separate,
- 9:34Speaker 2: and at that instant the bolt force jumps from that
- 9:37Speaker 2: tiny increase to carrying one hundred percent of the external load.
- 9:40Speaker 1: But it's never that simple in the real world, no,
- 9:43Speaker 1: because you almost always have prying action AH where the
- 9:46Speaker 1: flange or the connecting element bends and acts like a
- 9:49Speaker 1: little lever trying to rip the bolt head off.
- 9:51Speaker 2: That's the perfect way to picture it. That prying introduces
- 9:54Speaker 2: an extra force QU into the bolt. So the total
- 9:58Speaker 2: force the bolt feels is your ex external load T
- 10:01Speaker 2: plus this extra prying force Q. The designer's job is
- 10:04Speaker 2: to make the flange stiff enough to keep Q as
- 10:07Speaker 2: small as possible.
- 10:08Speaker 1: And what about fatigue for sheer connections, You said the
- 10:11Speaker 1: bolt itself is rarely the problem.
- 10:13Speaker 2: That's right. In sheer fatigue happens in the plate. For
- 10:16Speaker 2: a slip critical joint, it's fretting on the gross section.
- 10:19Speaker 2: For a bearing joint, a crack starts at the hole
- 10:21Speaker 2: and goes through the net section, which is much worse.
- 10:24Speaker 1: But for bolts intention the bolt itself is at risk.
- 10:27Speaker 2: Absolutely, the failure starts at the root of the thread
- 10:30Speaker 2: and fatigue life here is incredibly sensitive to two things,
- 10:34Speaker 2: keeping that high pertension and minimizing those prying forces which
- 10:38Speaker 2: create nasty bending stresses in the threads.
- 10:40Speaker 1: Calculating that stress range can get complicated, so designers sometimes
- 10:44Speaker 1: just use a rule of thumb, like assuming the stress
- 10:46Speaker 1: range is twenty percent of the service load.
- 10:48Speaker 2: Right, which shows how sometimes we rely on conservative assumptions
- 10:51Speaker 2: to keep designs practical while making sure they're safe.
- 10:54Speaker 1: Now, let's get into those vital practical details things every
- 10:57Speaker 1: young engineer needs to watch for on site. Let's start
- 11:00Speaker 1: with washers. When are they non negotiable?
- 11:03Speaker 2: Two primary situations. First, anytime you're using a torque controlled
- 11:07Speaker 2: installation method so calibrated rench or TC bolts, you need
- 11:11Speaker 2: that washer to get a consistent friction surface.
- 11:13Speaker 1: Okay. In the second, when.
- 11:15Speaker 2: You use high strength A four ninety bolts to connect
- 11:17Speaker 2: to a softer steel something with a yield strength under
- 11:20Speaker 2: forty KI, the washer prevents the bolt head or nut
- 11:23Speaker 2: from galling and digging into the softer plate.
- 11:25Speaker 1: And what if we're using oversized or slotted holes for
- 11:28Speaker 1: erection tolerance.
- 11:30Speaker 2: Then you need to seriously upgrade your washer. A standard
- 11:33Speaker 2: washer isn't stiff enough for pretensioned or slip critical joints.
- 11:38Speaker 2: You have to use thick, stiff plate washers, usually five
- 11:41Speaker 2: sixteen of an inch thick, to bridge that gap. If
- 11:43Speaker 2: you don't, you simply can't achieve the required pre load.
- 11:46Speaker 1: Next up a big one galvanizing. Can you galvanize a
- 11:50Speaker 1: four ninety bolts?
- 11:51Speaker 2: Absolutely not. Never galvanize a four ninety bolts. Their high
- 11:56Speaker 2: strength makes them susceptible to hydrogen embrittlement. During the galvanizing
- 11:59Speaker 2: par process, the steel becomes brittle and can fail catastrophically
- 12:03Speaker 2: with no warning.
- 12:04Speaker 1: But a three twenty five bolts are okay to galvanize.
- 12:07Speaker 2: They are with some critical precautions. Galvanizing adds a lot
- 12:10Speaker 2: of friction to the threads, so the nuts have to
- 12:12Speaker 2: be tapped, oversized, and they have to be properly lubricated.
- 12:14Speaker 2: If you don't do that, the bolt will either strip
- 12:16Speaker 2: the threads or just twist off before it ever gets
- 12:18Speaker 2: to the required tension.
- 12:19Speaker 1: Finally, the question you hear on every job site, can
- 12:22Speaker 1: we reuse high strength bolts.
- 12:23Speaker 2: The rules are very clear. You may never reuse A
- 12:26Speaker 2: four ninety bolts and you may never reuse any galvanized
- 12:29Speaker 2: A through twenty five bolts.
- 12:30Speaker 1: Why the absolute ban.
- 12:32Speaker 2: Because once a bolt has been fully pretensioned, it has yielded,
- 12:36Speaker 2: it has been stretched into its inelastic range, its dubtility
- 12:39Speaker 2: is used up. A four nineties are already less ductile
- 12:42Speaker 2: than A three twenty fives, so reusing them is just
- 12:45Speaker 2: too big a safety risk.
- 12:47Speaker 1: But black A three twenty fives can sometimes be reused.
- 12:49Speaker 2: They're the only exception. They can be reused maybe once
- 12:52Speaker 2: or twice, but only if the nuts still runs freely
- 12:55Speaker 2: on the threads by hand. That's the test that pretty.
- 12:58Speaker 1: Much covers the whole spectrum from to the field.
- 13:00Speaker 2: I think so the core idea is always the relationship
- 13:03Speaker 2: between the installation state and the design function. Pretension gives
- 13:07Speaker 2: you the friction for slip resistance, but it doesn't change
- 13:10Speaker 2: the bolt's ultimate sheer capacity.
- 13:13Speaker 1: So let's leave you with a final thought a review question.
- 13:15Speaker 1: You're designing a heavily loaded two line trust plice with
- 13:18Speaker 1: A four ninety bolts, should you specify it as slip
- 13:21Speaker 1: critical or bearing type and how does that decision change
- 13:24Speaker 1: your inspection requirements on site?
- 13:26Speaker 2: Think about what a trust does the load reversals and
- 13:29Speaker 2: what that means for what the inspector needs to verify.
- 13:31Speaker 2: Answering that that's the difference between knowing the rules and
- 13:34Speaker 2: really understanding engineering.
- 13:36Speaker 1: Until next time, keep designing strong