Latest / NTC's Temporal 3 / Episode 35 | Michael Ventola from Space Age Electronics, committee participation, ADA and accessibility on fire safety, and more
Transcript
- 0:01SPEAKER_01: Hello again, everyone, and welcome to the Temporal Three Podcast.
- 0:06SPEAKER_01: I'm your host, Brian McLean.
- 0:07SPEAKER_01: We're joined today by our special guest, Mr.
- 0:09SPEAKER_01: Michael Ventola.
- 0:10SPEAKER_01: Good morning, Michael.
- 0:12SPEAKER_01: Morning, Brian.
- 0:13SPEAKER_01: And my co-host, Mr.
- 0:14SPEAKER_01: Charles Elder.
- 0:15SPEAKER_01: Hello, Charles.
- 0:16SPEAKER_01: Good day.
- 0:17SPEAKER_01: Good day.
- 0:19SPEAKER_00: So, Michael, since you're a guest today, tell us a little bit about yourself.
- 0:22SPEAKER_00: What do you do?
- 0:23SPEAKER_00: So I'm currently working for Space Age Electronics.
- 0:27SPEAKER_00: I've been there for about 13 years now.
- 0:30SPEAKER_00: And when I do presentations, you know, people tell the audience how many years you've been in the industry.
- 0:37SPEAKER_00: Well, I use decades.
- 0:38SPEAKER_00: So I've been around for four decades and have really been in a number of roles.
- 0:44SPEAKER_00: I have a background in electronic engineering.
- 0:48SPEAKER_00: So I started on the technical side in the industry back in 86.
- 0:52SPEAKER_00: And, you know, from there I kind of progressed into sales and then design and working with engineers.
- 0:59SPEAKER_00: But along the way, you know, you kind of pick up all of this industry knowledge.
- 1:03SPEAKER_00: And then about four or five years ago with SpaceAge, I said, look, we need to be represented on the committee levels, NFPA, SFPE, you know, those of folks that know NISET, we've engaged with them.
- 1:18SPEAKER_00: But being at the table, you know, discussing the changes in the industry and what's coming is important.
- 1:24SPEAKER_00: So I went into industry relations, and now I get to draw on those four decades of experience and kind of bring that real-world application into code changes, code debate, and so forth.
- 1:36SPEAKER_00: So um so yeah, I sit on a number of committees, NFPA 92 for smoke control, 780s lightning protection, a new one, 461, is launch facilities and spaceports, and NFPA 72.
- 1:49SPEAKER_00: I'm on the uh IDS section there.
- 1:53SPEAKER_00: Awesome.
- 1:54SPEAKER_01: Well, thank you for sitting on the committees.
- 1:55SPEAKER_01: We appreciate when our industry professionals uh sit on committees and participate and help make things better, hopefully for the rest of us in fire protection.
- 2:03SPEAKER_01: So we uh we definitely appreciate that.
- 2:05SPEAKER_02: Well, I think it takes a special temperament and personality to be able to sit on a committee, Brian.
- 2:13SPEAKER_02: I don't know that you're suited for that.
- 2:15SPEAKER_02: No.
- 2:16SPEAKER_01: No.
- 2:17SPEAKER_01: I've been in this for 45 years, so I'm right there with you, Michael.
- 2:20SPEAKER_01: And uh Charles has got a number of years as well.
- 2:22SPEAKER_01: Uh old guy's rule.
- 2:24SPEAKER_01: So um, yeah, 45 years for me, but yeah, committee, sitting on a committee uh is not not ideal for me.
- 2:29SPEAKER_01: I don't play well with others.
- 2:32SPEAKER_00: Yeah, well, you know, seeing how the sausage is made, so to speak.
- 2:36SPEAKER_00: Um, and look at it, it's important, and I'll and I'll I'll kind of point this out to the audience because this process that NFPA has set up, and it's been used for over a hundred years, right?
- 2:48SPEAKER_00: Um, and it's gotten better.
- 2:50SPEAKER_00: But there is also this legislative debate that's going on at the state level.
- 2:56SPEAKER_00: And um, you know, state houses, their Senate and their Congress, are making changes, law changes to safety and construction, and they're doing it around the process.
- 3:08SPEAKER_00: And we could debate, people could rationalize why they're doing that.
- 3:12SPEAKER_00: Some of the some of the rationales are good, right?
- 3:15SPEAKER_00: But going outside the process just sets things up for failure, and that's not a good thing.
- 3:22SPEAKER_00: You have to have people with experience in the room debating what's being changed and why it's being changed.
- 3:29SPEAKER_01: So Absolutely, yeah.
- 3:30SPEAKER_01: And there's been a lot of that going on lately.
- 3:32SPEAKER_01: I agree.
- 3:33SPEAKER_01: We'll more than we could talk about in this one podcast.
- 3:36SPEAKER_01: That's a different, that's a different subject.
- 3:37SPEAKER_01: But yeah, there's I've heard a lot of scary things lately, and that that really uh concerns me as a fire protection professional.
- 3:43SPEAKER_01: I'm sure it concerns both you guys as well.
- 3:46SPEAKER_01: So, guys, first topic I'd like to talk about today is training and adding more acronyms to the end of your name.
- 3:53SPEAKER_01: My opinion is that the more acronyms that you have at the end of your name, the more valuable you are to your current employer and potential employers.
- 4:01SPEAKER_01: Michael, um, what certifications?
- 4:03SPEAKER_01: I know you've got multiple certifications, what certifications do you think are important in this industry?
- 4:09SPEAKER_00: Early on in my career, I was encouraged to go for NISAT.
- 4:13SPEAKER_00: So being technical and in the field, you know, getting those NISAT level one, two, all the way up to NISAT four on fire alarm and level two on special hazards.
- 4:24SPEAKER_00: But getting those accreditations does a number of things.
- 4:28SPEAKER_00: Number one, it certainly expands your knowledge base, makes you more valuable to your employer, but it also comes with the salary increases, or you could pretty much demand more from your employer.
- 4:39SPEAKER_00: Um, after that, I went in and got my CFPS, which is a certified fire protection specialist, which is a much more difficult undertaking.
- 4:48SPEAKER_00: That took me two years.
- 4:49SPEAKER_00: I didn't pass on the first test.
- 4:51SPEAKER_00: And where NISAT is pretty focused in a module or discipline, that CFPS, which is which is actually governed through NFPA, you know, that book is this thick.
- 5:02SPEAKER_00: So it's a pretty broad undertaking.
- 5:05SPEAKER_00: You know, aside from that, you know, you know, engineering degree in electronics, which is associate engineering degree, just being involved with industry training and education might not come with some letters at the end of your end of your name, but you know, you could say you attended these cer certification programs, uh, which is important, right?
- 5:27SPEAKER_00: Learning the technology, whether it's BDA systems or programming logic on uh addressable fire alarm system, all of that helps the individual in the future.
- 5:38SPEAKER_01: Absolutely.
- 5:40SPEAKER_01: Charles, I know you're a big proponent of NIFESET, as I am as well, and obviously as Michael is.
- 5:44SPEAKER_01: What's your take on this?
- 5:45SPEAKER_01: What acronyms uh would you like to add to the end of your name?
- 5:49SPEAKER_02: Well, I I think it's an important consideration that the learning comes first and the acronyms come second.
- 5:57SPEAKER_02: Great point.
- 5:58SPEAKER_02: In our profession, the acronyms are an indication of our professionalism and what we've learned over the course of experience.
- 6:07SPEAKER_02: So I think that's an important aspect of it uh in a really big way.
- 6:13SPEAKER_02: An ISAT certification for fire alarm systems is really, really a big deal.
- 6:20SPEAKER_02: There's so many other trainings out there that are available.
- 6:24SPEAKER_02: Uh the NFTA C FTS certification, as uh we've already discussed, is one of the big ones.
- 6:32SPEAKER_02: Um any training we get and any certification that we get just adds to the professionalism that we occupy in this industry space.
- 6:43SPEAKER_02: Absolutely.
- 6:44SPEAKER_01: Michael, I see that you guys offer uh something that you were involved in as uh CEUs for ICC certification.
- 6:51SPEAKER_01: Are you starting to see ICC certification or ICC programs uh becoming more widely accepted in fire alarm or fire sprinkler?
- 7:01SPEAKER_00: Yes, certainly in many of the life safety disciplines.
- 7:05SPEAKER_00: So that International Code Council, the ICC um website actually has a kind of like a side portal where manufacturers or content providers, Space Age is one of those, can sign up in their preferred program and then facilitate these trainings.
- 7:27SPEAKER_00: So about two and a half years ago, we Space Age, we put together this series, Ignite training series, and we focused on the specific disciplines where Space Age excels.
- 7:39SPEAKER_00: It's in our wheelhouse, so to speak.
- 7:41SPEAKER_00: Sure.
- 7:41SPEAKER_01: Yeah.
- 7:41SPEAKER_00: But using ICC as the accreditation body, we could submit our course content, the synopsis, and then get the CEU accredited, and then we could offer those CEUs once uh individuals take our programs.
- 7:58SPEAKER_00: And these are free.
- 7:58SPEAKER_00: We offer them free twice a month.
- 8:00SPEAKER_00: You can find it from our onesae.com website, Ignite series, and some of the topics that we focused on smoke control, which is one of my expert areas, two-way communications, service protection, emergency control functions.
- 8:17SPEAKER_00: We're doing one, it's a new one actually this month, it'll be out.
- 8:20SPEAKER_00: Um, NFPA 241, which we actually sit on that, I'm not on that uh committee, but Kyle Jarvinpa's on that committee.
- 8:27SPEAKER_00: NFPA 241 is safety in new construction, renovation, and alteration.
- 8:33SPEAKER_00: So if anybody's been watching the news or on LinkedIn and you see these construction sites burned to the ground, right?
- 8:39SPEAKER_00: They're wood frame construction, typically that medium apartment complex, four-story, five-story type of construction, and they're gone in minutes, you know, under an hour.
- 8:51SPEAKER_00: Wow.
- 8:51SPEAKER_00: That's NFPA 241, that's safety uh for construction sites.
- 8:55SPEAKER_00: So I do a presentation on that, and that's coming up on I think it's the 27th of this month.
- 9:02SPEAKER_01: Awesome.
- 9:03SPEAKER_01: So those of you that may have missed it, I'll repeat the website one the number onesae.com, and it's the Ignite series program, and you can uh find out more information there, and uh obviously want to join and check out Michael, uh, one of his events on there and get your ICC CEUs.
- 9:19SPEAKER_01: And also, uh, if it is related to your certification, it could be applied for nice at CPD points as well.
- 9:25SPEAKER_01: That's correct.
- 9:26SPEAKER_01: Yeah.
- 9:27SPEAKER_01: Well, next topic I'd like to talk about, guys, is from NFPA 70, and that's fire alarm circuit identification.
- 9:33SPEAKER_01: And 760.30, which is in part one general requirement, says fire alarm circuits shall be identified at termination and junction locations in a manner that helps prevent unintentional signals on the fire alarm system circuits during testing, servicing, and of other systems.
- 9:50SPEAKER_01: So very vaguely, 70 tells us is basically at circuits and junctions, we have to identify them.
- 9:58SPEAKER_01: Now it does leave the identification method, how it's identified, up to the AHJ.
- 10:04SPEAKER_01: So it's really interesting.
- 10:05SPEAKER_01: We always have this discussion with our students, particularly in our NISAC classes, because everybody's under the impression that fire alarm cable has to be red, that fire alarm junction boxes have to be red because it says it in the code.
- 10:17SPEAKER_01: And actually, you will not find the term red in Article 760.
- 10:21SPEAKER_01: So they don't just say required identification, but add a method acceptable to the AHJ.
- 10:26SPEAKER_01: And in the eyes of most AHJs, fire alarm is red.
- 10:30SPEAKER_01: So anything having to do with fire alarm will be red.
- 10:33SPEAKER_01: There's a common, a couple of common different methods of identification.
- 10:36SPEAKER_01: What method are you commonly seeing, Michael?
- 10:38SPEAKER_01: What have you generally seen as the method of identification?
- 10:41SPEAKER_00: So it's certainly red.
- 10:43SPEAKER_00: It's marking the collars on conduit boxes.
- 10:47SPEAKER_00: So Space Age, who's only been in the industry for a little over 64 years.
- 10:54SPEAKER_00: So we can see you use decades against.
- 10:57SPEAKER_01: Newcomers.
- 10:58SPEAKER_01: New covers.
- 10:59SPEAKER_00: Yeah.
- 10:59SPEAKER_00: We're American-made.
- 11:00SPEAKER_00: We've always bought locally in our steel markets.
- 11:03SPEAKER_00: But we've always been the proponent of putting forth new well-listed solutions for life safety.
- 11:11SPEAKER_00: And I I know in in 760 or NFPA 70, when we get into 760, which is where fire alarm is, you know, it kind of alludes to terminal cabinets and junction boxes being read, being marked and identified, primarily because when these systems are in place, let's use a hospital as an example, and you go above a ceiling, there is conduit everywhere with duct work, HVAC, you know, systems and so forth, not to mention any medical gas piping, which has also got its own color coding.
- 11:47SPEAKER_00: Right.
- 11:48SPEAKER_00: So you have to identify this stuff.
- 11:50SPEAKER_00: And when electricians are up there making adjustments, maybe it's lighting, you don't want to be messing with anything red, right?
- 11:56SPEAKER_00: So SpaceJase has always promoted that.
- 11:59SPEAKER_00: Now, there's also phraseology in the codes and standards that reference products that are listed for their intended purpose, shall be used.
- 12:10SPEAKER_00: It's not maybe you could use them or you should use them.
- 12:13SPEAKER_00: It's a shall.
- 12:14SPEAKER_00: And our products, the terminal cabinets, for example, are actually UL864 listed accessories.
- 12:20SPEAKER_00: And one of the best things it's corrosion resistance.
- 12:24SPEAKER_00: So all our products are powder coated and every surface is finished, which means there's no exposure to any oxidizers for rust to build up.
- 12:34SPEAKER_00: And those are guaranteed for a minimum of 10 years, most likely longer.
- 12:38SPEAKER_00: That's one of the differences between a non-UL864 accessory versus somebody that buys a Galvey box and screws some terminals in the back of it and there's no offset off the back.
- 12:50SPEAKER_00: You know, who knows how long that's gonna last, right?
- 12:53SPEAKER_00: And then it's not marked.
- 12:54SPEAKER_00: It's not red.
- 12:56SPEAKER_00: They don't paint them.
- 12:57SPEAKER_00: The other thing that we like to see is when you actually are putting in terminal cabinets, put the name on the door.
- 13:04SPEAKER_00: It's a damper control interface.
- 13:06SPEAKER_00: Maybe it's just a terminal cabinet.
- 13:08SPEAKER_00: Maybe it's an elevator recall cabinet, right?
- 13:12SPEAKER_00: Where terminations are made inside these enclosures.
- 13:14SPEAKER_00: And what it does is later on, 10 years, when they're servicing this equipment and a technician goes back out there, oh, there's the damper cabinet.
- 13:23SPEAKER_00: This is the elevator recall cabinet.
- 13:25SPEAKER_00: I had a contractor, he did a big box plant, like an Amazon warehouse, one of those things.
- 13:30SPEAKER_00: And he and they put terminal, they put surge protection on all the PIVs and water flow switches.
- 13:36SPEAKER_00: But they put a box, they put the surge protector in there, and they didn't label any of them.
- 13:41SPEAKER_00: Wow.
- 13:41SPEAKER_00: So when they had a problem, they didn't know which boxes had surge protection and which boxes had the module behind it.
- 13:49SPEAKER_00: Right.
- 13:50SPEAKER_00: So they they couldn't tell.
- 13:52SPEAKER_00: So it was really difficult for them.
- 13:54SPEAKER_00: But once again, you mark something like that, and it just makes the technician's life much easier, as well as the owner, when they have to go back and say, Yeah, we gotta we've got to upgrade our system.
- 14:04SPEAKER_00: You know, these are the these are the boxes we have to access and and maybe take stuff out and put a new product in.
- 14:10SPEAKER_00: Absolutely.
- 14:11SPEAKER_01: Charles, from your experience working in the field.
- 14:15SPEAKER_02: NFTA 70 has a term workman like manager.
- 14:21SPEAKER_02: And what exactly does that mean?
- 14:23SPEAKER_02: Well, I think it goes to our earlier discussion, at least in part, that we as professionals in the industry need to have some certifications.
- 14:33SPEAKER_02: Well, on the job site, when we install equipment, we should do that in a professional manner too.
- 14:41SPEAKER_02: And the items that uh Michael has been discussing, that is what makes a difference between a professional installation and something that looks other than workmanlike.
- 14:54SPEAKER_02: Using a Sharpie on a uh box trucker that says fire alarm probably is outside that workmanlike manner, and it's certainly not something someone with acronyms behind their names and uh professionalism in the industry would want to use.
- 15:11SPEAKER_02: So going with space age products and other things that help make that installation professional is absolutely the way to go.
- 15:21SPEAKER_02: Fire alarm systems are not cheap, they're very expensive, and adding this level of professionalism is a minor cost in the overall budget of a of a system, in my view.
- 15:35SPEAKER_00: Yeah.
- 15:35SPEAKER_00: Also, just to add Charles, you know, in different parts of the country they spell fire differently.
- 15:41SPEAKER_00: It could be fur alarm.
- 15:44SPEAKER_00: We don't know how it's gonna be spelled on that box in the in the stairwell.
- 15:49SPEAKER_01: Um I was just gonna say that, Michael, that in the South we spell it Farlarm.
- 15:54SPEAKER_01: Right.
- 15:57SPEAKER_01: Plus, if you have handwriting like mine, Charles, you've seen my handwriting.
- 16:00SPEAKER_01: I write like a doctor writing a prescription.
- 16:03SPEAKER_01: So I it would be a completely undiagnosable.
- 16:05SPEAKER_01: Michael, you bring up an excellent point about the uh identification of the boxes because we always think, well, it's on the record drawings.
- 16:13SPEAKER_01: And the thing is, with the record drawings, first of all, they may not necessarily be completely up to date and accurate, and they may not be accessible.
- 16:20SPEAKER_01: You know, they're they're the responsibility of the property owner.
- 16:22SPEAKER_01: What does the property owner immediately do with them?
- 16:24SPEAKER_01: He lose them because it's not important.
- 16:26SPEAKER_01: Now the technician comes out 10 years later, and it's so great to know where the elevator interface is, where the surge protection device is, where everything is.
- 16:36SPEAKER_01: And having that documentation on the box is so important.
- 16:41SPEAKER_01: And uh something that isn't specifically covered by Co.
- 16:44SPEAKER_01: but is great practice.
- 16:45SPEAKER_01: Charles?
- 16:46SPEAKER_02: Brian, if there was only uh someone who had a product like a terminal box that had a memory uh storage device attached to it, you could just digitally download the uh the record drawings or whatever to, that would be so nice.
- 17:05SPEAKER_01: Yeah.
- 17:06SPEAKER_02: You guys should get on that, Michael.
- 17:09SPEAKER_00: You know, funny story, and uh on that on the document box, system record document box, which is required in chapter 14 of NFPA 72, has been since 2013, folks.
- 17:21SPEAKER_00: So that's 13 years ago.
- 17:23SPEAKER_00: Space Age was actually making a system record document box before it was actually in the standard.
- 17:30SPEAKER_00: Why do we do that?
- 17:32SPEAKER_00: Because we know that there's a need for a solution as simple as that is, a box, right, red that says system record documents on it.
- 17:42SPEAKER_00: We were doing that before it was needed.
- 17:44SPEAKER_00: That means that when a customer does need it or is held to that standard, there's a place to get it.
- 17:51SPEAKER_00: Okay.
- 17:51SPEAKER_00: One better.
- 17:53SPEAKER_00: Wouldn't it be nice with all of the lock sets on the entire job side to be keyed the same as the fire alarm control panel?
- 18:02SPEAKER_00: A little thing like that.
- 18:03SPEAKER_00: We've been doing that for decades, right?
- 18:06SPEAKER_00: So the dock box key is the same, the fire alarm panel key is the same, the battery box keys are the same, all of the terminal box keys are the same, and you got one key.
- 18:16SPEAKER_00: And once again, a little thing like that, which no one really thinks about, but we thought about it, and we offer that.
- 18:23SPEAKER_00: There's no extra cost for that.
- 18:24SPEAKER_00: If you order that with that key set, you're gonna get it.
- 18:27SPEAKER_00: So it's the same price.
- 18:28SPEAKER_00: It's not like you're paying more.
- 18:30SPEAKER_00: So why not just do it right in the professional manner that Charles was paying?
- 18:35SPEAKER_00: Exactly.
- 18:36SPEAKER_02: You're destroying something that's integral to our society.
- 18:42SPEAKER_02: Uh in the fire alarm industry, the older the tech, the bigger the keyring.
- 18:49SPEAKER_01: Yes.
- 18:51SPEAKER_02: You're eliminating that with only one key, dude.
- 18:54SPEAKER_01: I was just gonna bring that up.
- 18:56SPEAKER_01: You're gonna disappoint all the older techs out there that have the huge keyrings with all the keys on it.
- 19:01SPEAKER_00: Well, you can you can still have all the manufacturer's keys.
- 19:06SPEAKER_00: So if you're working, you can still have a dozen or so of those.
- 19:11SPEAKER_01: Well, gentlemen, our our next topic, our final topic today is from a student.
- 19:16SPEAKER_01: What is an area of refuge or area of rescue system?
- 19:19SPEAKER_01: So this is something that is covered by NFPA 72.
- 19:22SPEAKER_01: Something really good that uh NFPA did back in 2010 was incorporate emergency communication systems, which include or rolled in voice EVAC, but also other voice systems in the building uh into a chapter of NFPA 72.
- 19:39SPEAKER_01: So that's been what, 16 years now that that's been in there.
- 19:42SPEAKER_01: And uh chapter 24 covers emergency communication systems.
- 19:46SPEAKER_01: And within chapter 24, they classify one-way and two-way systems.
- 19:51SPEAKER_01: An area of refuge system is classified as a two-way emergency communication system.
- 19:56SPEAKER_01: And these systems, in general, two-way emergency communication systems are used by building occupants or emergency responders for two-way communication.
- 20:07SPEAKER_01: So the two-way part of it includes things like firemen's phones, which obviously are used by the first responders.
- 20:12SPEAKER_01: And I know that's kind of gone by the wayside since radio ERXES is much more easier to deal with, uh, but also includes area of rescue, elevator telephone, stairwell communications, anything else that allows two-way communication.
- 20:28SPEAKER_01: And 24.10 talks specifically about ECS for rescue assistance.
- 20:33SPEAKER_01: Michael, do you want to talk a little bit about that, about what the requirements are and how that works?
- 20:38SPEAKER_00: Yes.
- 20:39SPEAKER_00: So that chapter 24 in NFPA 72, it does have the BDA system or ERCS systems as part of one of the emergency communication systems.
- 20:48SPEAKER_00: In there is firefighter telephones, there's stairwell communication systems, and then emergency communication systems, which is which we call the area.
- 20:57SPEAKER_00: It was called the area of refuge system, but that was a problem, right?
- 21:01SPEAKER_00: Because and those are two different things.
- 21:03SPEAKER_00: An area of refuge is different from the two-way emergency communication system that goes into an area of refuge.
- 21:10SPEAKER_00: So where does this all start?
- 21:12SPEAKER_00: It all started, and I'll I'll do it quickly here, but it all started back in 1991 with the American with Disabilities Act.
- 21:21SPEAKER_00: And basically, with that law, where you have the public entering and leaving, has to be capable of accessibility to everyone.
- 21:31SPEAKER_00: And that accessibility means that an individual that may be in a wheelchair could get in and out of a building safely, using ramps and so forth.
- 21:41SPEAKER_00: Uh maybe a blind person is able to read signage using braille, hearing impaired people, there's provisions uh put in place in these public spaces for those individuals.
- 21:52SPEAKER_00: It's accessibility to everyone.
- 21:56SPEAKER_00: And it's important to understand because in chapter 10 of the I.
- 22:00SPEAKER_00: IBC, that is the chapter on means of egress out of a structure, out of a building.
- 22:06SPEAKER_00: So you're building an office building, a high-rise office building, okay, that's going to be in chapter four of IBC.
- 22:15SPEAKER_00: But the means of egress of that building is going to be clearly defined.
- 22:21SPEAKER_00: And what is the means of egress?
- 22:23SPEAKER_00: It is from a location within the building, an unobstructed path.
- 22:29SPEAKER_00: Most buildings require two.
- 22:30SPEAKER_00: And in that means of egress, in that path, there has to be an area of refuge if the accessibility out of the building is not facilitated for all, meaning they're stuck.
- 22:43SPEAKER_00: They can't use the stairs.
- 22:44SPEAKER_00: They're not using the elevators, aren't designated as a means of egress, meaning they don't have backup power.
- 22:50SPEAKER_00: They don't have the safety provisions that someone in a wheelchair could get into an elevator, push the button, and get out of the building.
- 22:57SPEAKER_00: Right.
- 22:58SPEAKER_00: That area of refuge, once they have those defined, okay, and it's based on occupancy.
- 23:03SPEAKER_00: So typically the cutoff is about 200.
- 23:07SPEAKER_00: But the area of refuge is based on the occupancy and how many wheelchair spaces will be in there.
- 23:12SPEAKER_00: You you shall have this two-way communication system.
- 23:16SPEAKER_00: Okay.
- 23:16SPEAKER_00: So so the the means of egress out of the building, that's the path, has to have an area of refuge, right?
- 23:23SPEAKER_00: Unless there's ramps, but typically any building over two stories or more, and you don't have ramps to get out of the building, you're going to have to have an area of refuge.
- 23:31SPEAKER_00: Right.
- 23:32SPEAKER_00: Right.
- 23:33SPEAKER_00: Where that is could be in a stairwell, it could be in an elevator lobby, it could be in a horizontal exit.
- 23:38SPEAKER_00: Okay.
- 23:38SPEAKER_00: That has to be defined by the architects.
- 23:40SPEAKER_00: But wherever that is, you'll have this two-way communication system.
- 23:44SPEAKER_00: Now, prior to 2022, these systems that were being used were just like intercom systems.
- 23:52SPEAKER_00: You know, you'd uh those that watch Seinfeld, you know, hey, George buzzes in and he hits the buzzard down to the front door, right?
- 24:00SPEAKER_00: That's what they were using.
- 24:01SPEAKER_00: They were they were using these intercom systems.
- 24:04SPEAKER_00: You push the button, you talk, and you know, you somebody's at down at the entrance.
- 24:08SPEAKER_00: Um, unsupervised, no backup power, susceptible to transient voltages, the whole nine years, right?
- 24:15SPEAKER_00: Sometimes not weatherproof, weather-rated, so forth.
- 24:19SPEAKER_00: But now in 2022, UL comes out with 2525.
- 24:23SPEAKER_00: UL2525 is the standard by which this equipment is tested against.
- 24:28SPEAKER_00: And for those of us in the fire alarm industry, we're very familiar with UL864, right?
- 24:33SPEAKER_00: Where that's testing of the fire alarm control units in today's two-way communication systems, UL2525 listed, um, do all those same testing.
- 24:42SPEAKER_00: It's not as rigorous, it's not as much as fire alarm, but there is supervision, there's battery chargers, low battery, battery faults.
- 24:51SPEAKER_00: You've got to pick all those troubles up and report them off-site.
- 24:55SPEAKER_00: So there's an off-site communicator that would be required.
- 24:58SPEAKER_00: The person in the area of refuge pushes the button, it calls down to a head-end unit.
- 25:03SPEAKER_00: If that's not a 24-hour manned location, it could be a security desk.
- 25:08SPEAKER_00: Okay, fine.
- 25:09SPEAKER_00: But if it's not, it has to call off-site to a central station.
- 25:13SPEAKER_00: And then that central station can talk back into the building and communicate with the individual on whatever level they're at.
- 25:22SPEAKER_00: So I know it's a lot there.
- 25:24SPEAKER_01: Um no, no, that's that's perfectly fine.
- 25:26SPEAKER_01: And um, you know, I see it as an opportunity for fire alarm people because we're already in the building doing the fire alarm.
- 25:31SPEAKER_01: It's a natural extension, it's a code requirement.
- 25:33SPEAKER_01: You know, we in fire alarm, we live code.
- 25:36SPEAKER_01: So it's something that uh fire alarm people should be looking at uh if they're doing a project.
- 25:43SPEAKER_01: Is there an area of refuge, area rescue system required in the building?
- 25:47SPEAKER_01: There's a lot of the manufacturers in fire alarm that offer this product or you know, something that you can get, but the fact that the standby power requirements, 24 hours, standby, four hours of operation, supervision of the circuits, the remote communication to a monitoring facility, uh, all that stuff kind of falls in our wheelhouse.
- 26:06SPEAKER_01: And uh something that we definitely should look at doing if it's on a project.
- 26:11SPEAKER_01: Charles, what do you think about this topic?
- 26:14SPEAKER_02: Yeah, I've had very limited experience with uh this myself in the field, so I can read the information out of the code, but as far as practical application goes, I'm very limited in my experience of that.
- 26:30SPEAKER_01: I do have experience with it from distribution, and I do remember when that change occurred that, yeah, uh Michael's absolutely right.
- 26:37SPEAKER_01: Back in the old days, they were basically just intercom systems, and then the code came out and the changes came out, and all of a sudden there are these new ones.
- 26:44SPEAKER_01: You know, they have the indicator that indicates a connection, has to have an audible and visible indication.
- 26:49SPEAKER_01: The remote communication wasn't in there previously, that's something that got added in.
- 26:54SPEAKER_01: Um, all that stuff changed, and uh, that equipment went from being just uh basically a basic intercom to something that was much more sophisticated when uh that code change occurred.
- 27:06SPEAKER_01: Yeah.
- 27:06SPEAKER_01: And um, yeah, I remember that from distribution and all those new products or that new, wasn't just like you said, Michael, just a straight up intercom, a Seinfeld uh doorbell intercom type of thing.
- 27:17SPEAKER_01: Now the new equipment doesn't take doesn't take Festivus off.
- 27:20SPEAKER_01: It has to work on Festivus.
- 27:21SPEAKER_00: Right, right, right.
- 27:22SPEAKER_00: Well, and look to throw a little more complexity into this.
- 27:25SPEAKER_00: So for those that are familiar with pathway designation, pathway survivability, which is in chapter 12 of NFPA 72, these systems are in a, let's say, typically a two-hour rated enclosure.
- 27:40SPEAKER_00: So it's a two-hour compartment stairwell that's gonna survive fire attack for two hours, right?
- 27:48SPEAKER_00: So that's like your type one construction, A or B, typically it's gonna be two hours.
- 27:53SPEAKER_00: Well, the pathway, which is the wiring connections, between the head end unit, which may be in the fire command center, to all of the stations that are in all of the area of refuges has to be survivable.
- 28:07SPEAKER_00: So if the building's rated for two hours, that pathway has to be two hours.
- 28:12SPEAKER_00: If it's a one-hour rated building, so a type type two or type three, and some of some of the newer construction that they do this um they call a one over five type one base, which is a concrete, you know, steel base, and then they do the type five construction, which is wood, small dimensional lumber wood on top of it.
- 28:32SPEAKER_00: These are these are typically these lower cost apartment built or condos.
- 28:36SPEAKER_00: Well, you're gonna have to have an area of refuge system in there.
- 28:38SPEAKER_00: Area of refuge with the two-way mirrors of communication system in there.
- 28:42SPEAKER_00: Well, do you do two-hour pathway or do you do one hour in the one-hour structure?
- 28:46SPEAKER_00: These are some of the engineering decisions that have to be made up front.
- 28:50SPEAKER_00: Because we all know that cable they call CI cable.
- 28:54SPEAKER_00: Right.
- 28:55SPEAKER_00: That's it stands for cost intensive.
- 28:57SPEAKER_00: It's yeah, not easy to work with and it's very expensive.
- 29:03SPEAKER_00: And the thing about that cable, it's not just the cable, it's the system.
- 29:08SPEAKER_00: Right.
- 29:08SPEAKER_00: So when you all test that system, it's the anchors, it's the it's the uh branch circuits, or any of the turns, as well as the cable.
- 29:19SPEAKER_00: So the system has to hold up for two hours under fire threat, which is pretty intense.
- 29:26SPEAKER_00: And and it's not just a piece of wire, right?
- 29:29SPEAKER_00: With some ceramic jacketing on it.
- 29:31SPEAKER_00: It's the system.
- 29:33SPEAKER_00: And and it has to be installed correctly.
- 29:35SPEAKER_00: If it's not even installed correctly, I don't care what wire you put in there, where you put it, it's gonna fail.
- 29:41SPEAKER_00: And that's the problem.
- 29:43SPEAKER_00: Absolutely.
- 29:44SPEAKER_01: Well, gentlemen, I appreciate the lively and interesting discussion on fire alarm today.
- 29:50SPEAKER_01: I want to thank all our listeners for joining us.
- 29:52SPEAKER_01: And please uh remember to like and subscribe to this podcast.
- 29:56SPEAKER_01: Michael, thank you again for your time.
- 29:58SPEAKER_01: Thank you, Michael.
- 29:59SPEAKER_02: It was very, very informative.
- 30:02SPEAKER_02: I appreciate all the knowledge that you've shared with us too.
- 30:05SPEAKER_02: Absolutely.
- 30:06SPEAKER_00: Thank you, Brian.
- 30:07SPEAKER_00: Thank you, Charles.
- 30:07SPEAKER_00: It was a pleasure.
- 30:08SPEAKER_00: I'm glad you reached out.
- 30:10SPEAKER_00: Awesome.
- 30:11SPEAKER_00: Well, great.
- 30:12SPEAKER_00: We'll see you all next time.
- 30:14SPEAKER_00: All right, take care.