Latest / Civil Engineering Made Simple / Steel Design Guide: Floor Vibrations Due to Human Activity
Transcript
- 0:00Speaker 1: Welcome to the deep dive, the place where we take
- 0:02Speaker 1: complex engineering standards, you know, the really dense stuff, and
- 0:06Speaker 1: break it down into the knowledge you can actually use.
- 0:08Speaker 2: Today, we're tackling a topic that well every structural engineer
- 0:12Speaker 2: runs into, how floors react when people move on them.
- 0:16Speaker 2: We're doing a full analysis of the AIIC design Guy
- 0:19Speaker 2: eleven floor vibrations due to human activity, and.
- 0:23Speaker 1: It really does transform what feels like a tricky, almost
- 0:26Speaker 1: subjective serviceability issue into practical design criteria.
- 0:31Speaker 2: It does. Our mission today is pretty straightforward. We want
- 0:33Speaker 2: to equip you, whether you're a student, young professional, or
- 0:36Speaker 2: just someone curious, with the principles you need to design
- 0:40Speaker 2: steel framed floors that feel solid not.
- 0:43Speaker 1: Springy, right, because that's the real problem is it is.
- 0:46Speaker 2: This deep dive is so important because well, we've learned
- 0:48Speaker 2: the hard way that the old rules, you know, the
- 0:50Speaker 2: static stiffness limits like span over three sixty, they just
- 0:54Speaker 2: earn enough anymore.
- 0:54Speaker 1: Especially with modern construction.
- 0:57Speaker 2: Exactly about thirty years ago, designs got life, spans got longer,
- 1:01Speaker 2: and suddenly resonance became the thing we had to worry about.
- 1:05Speaker 2: We have to think dynamically now.
- 1:06Speaker 1: Okay, so let's start there, let's unpack the basic mechanics,
- 1:09Speaker 1: frequency and resonance.
- 1:11Speaker 2: So frequency F is just the reciprocal of the period
- 1:15Speaker 2: measured and hurts, pretty simple. But resonance that's the whole game.
- 1:19Speaker 2: It's what happens when a forcing frequency like the beat
- 1:22Speaker 2: of someone walking, matches the structure's own natural frequency.
- 1:26Speaker 1: F sub n, and when they line up.
- 1:28Speaker 2: The structure amplifies the motion. I mean, it amplifies it dramatically,
- 1:32Speaker 2: and almost this entire guide is about how to avoid that,
- 1:36Speaker 2: or if you can't, how to control it.
- 1:38Speaker 1: And we're dealing with different kinds of loads here, right, we.
- 1:41Speaker 2: Have to differentiate. You've got transient loads that's a single
- 1:44Speaker 2: impulse like one footstep or someone dropping something. And then
- 1:47Speaker 2: you have periodic.
- 1:48Speaker 1: Loads, the repetitive stuff.
- 1:49Speaker 2: The repetitive stuff like dancing or aerobics or even some
- 1:52Speaker 2: industrial machines.
- 1:54Speaker 1: So for those continuous forces, how do we model them?
- 1:57Speaker 2: We use a FOURYA series. It basically breaks down a
- 2:00Speaker 2: complex repeating force into a bunch of simple sin ways,
- 2:03Speaker 2: which we call harmonics. And for walking, the key thing
- 2:07Speaker 2: to know is that the force magnitude for each harmonic,
- 2:10Speaker 2: this alpha coefficient, it drops off really really fast.
- 2:14Speaker 1: So the first harmonic is the biggest punch by far.
- 2:17Speaker 2: The first four might have coefficients like point five point two,
- 2:20Speaker 2: point one point oh five. That primary force is the biggest. Yeah,
- 2:24Speaker 2: but it's often those smaller, faster harmonics that actually line
- 2:28Speaker 2: up with the floors frequency and trigger resonance.
- 2:31Speaker 1: Okay, last basic concept damping beta. This is the system's
- 2:35Speaker 1: ability to just bleed off energy.
- 2:38Speaker 2: Right, It's the system's ability to dissipate that mechanical energy,
- 2:41Speaker 2: and we usually express it as a percentage of critical damping.
- 2:44Speaker 2: And yet, to be careful here, there's true modal damping
- 2:47Speaker 2: energy loss or friction inside the material. And then there's
- 2:50Speaker 2: something called geometric.
- 2:51Speaker 1: Dispersion, which isn't really damping at all.
- 2:53Speaker 2: Not really, No, it's just energy radiating away from the
- 2:56Speaker 2: source moving through the floor to the supports. Once you
- 3:00Speaker 2: filter that out, you find that for a typical office building,
- 3:03Speaker 2: the real modal damping is usually in a pretty tight range,
- 3:06Speaker 2: maybe three to five percent.
- 3:08Speaker 1: Okay, so we've got the inputs to find. Let's talk
- 3:10Speaker 1: about the goal section one acceptance criteria. How much movement
- 3:15Speaker 1: is actually too much? Because that feels incredibly subjective.
- 3:19Speaker 2: It is entirely subjective, and the criteria which come from
- 3:23Speaker 2: an isostandard are purely performance based. It all depends on
- 3:27Speaker 2: what the person is doing and where they are.
- 3:29Speaker 1: So what does that sensitivity spectrum look like?
- 3:31Speaker 2: Well, for quiet places, thing residences, private offices, people expect
- 3:35Speaker 2: almost no movement. Their tolerance the limb is super low,
- 3:40Speaker 2: but half a percent of gravity's acceleration or zero point
- 3:43Speaker 2: five percent G.
- 3:44Speaker 1: Okay.
- 3:45Speaker 2: But if you're in a busier area like a shopping
- 3:47Speaker 2: mall or a restaurant, people will accept more, maybe up
- 3:49Speaker 2: to about one point five percent G. And then you know,
- 3:52Speaker 2: if you're the one making the vibration, like in an
- 3:54Speaker 2: aerobics class, you'll tolerate five percent G or even more so.
- 3:58Speaker 1: The core of the design for walking is all one formula, right,
- 4:01Speaker 1: the one for peak acceleration.
- 4:02Speaker 2: It is the formula compares your estimated peak acceleration at
- 4:06Speaker 2: over G to that occupancy limit a limb over G.
- 4:10Speaker 2: But the most critical insight in that whole equation is
- 4:13Speaker 2: the exponential decay term E to the minus zero point
- 4:16Speaker 2: three P five FN.
- 4:18Speaker 1: What does that tell us?
- 4:19Speaker 2: It shows that as your floor's natural frequency FN goes up,
- 4:23Speaker 2: the dynamic impact of walking goes down exponentially, So increasing
- 4:28Speaker 2: FN is your single most powerful tool for killing vibration
- 4:31Speaker 2: from walking.
- 4:31Speaker 1: That's a huge takeaway. But what if a floor is
- 4:34Speaker 1: already super stiff? Do you stn't need to check it? Oh?
- 4:36Speaker 2: Absolutely, The guide has a specific check for floors with
- 4:39Speaker 2: a very high frequency, say above nine or ten hertz.
- 4:41Speaker 2: At that point, resonance isn't really a concern. But the
- 4:45Speaker 2: immediate thump of a footstep, that impulse still matters, the thud,
- 4:49Speaker 2: the thud exactly. Yeah, So for those high frequency floors
- 4:52Speaker 2: in offices or homes, you still have to check for
- 4:54Speaker 2: a minimum static stiffness of one killing Newton's per millimeter
- 4:57Speaker 2: under a print load that prevents those an localized impacts.
- 5:01Speaker 1: It's kind of wild that we're using a static calculation
- 5:04Speaker 1: to figure out a dynamic property, which brings us to
- 5:08Speaker 1: section two, maybe the most important part of the guide.
- 5:12Speaker 1: It's all about natural frequency s N. How can static
- 5:17Speaker 1: deflection tell us about frequency?
- 5:20Speaker 2: It's one of the most elegant simplifications in dynamics. Really.
- 5:24Speaker 2: The fundamental equation tells us that FN is inversely proportional
- 5:28Speaker 2: to the square root of the static midstand deflection delta.
- 5:32Speaker 1: So less deflection means a higher frequency exactly.
- 5:35Speaker 2: Less deflection means a stiffer floor, which means a higher
- 5:37Speaker 2: frequency and a better performing floor from a vibration standpoint.
- 5:41Speaker 2: It's a direct link.
- 5:42Speaker 1: But of course most floors aren't simple beams. You've got
- 5:44Speaker 1: joists on girders and a slab on top of that.
- 5:47Speaker 1: How do you combine all those individual frequencies into one
- 5:50Speaker 1: system frequency.
- 5:51Speaker 2: We use an approximation called the Dunkerly relationship. It basically
- 5:54Speaker 2: says that the flexibility of the whole system is the
- 5:57Speaker 2: sum of the flexibilities of its parts. So you combine
- 5:59Speaker 2: the Joye frequency and the girder frequency using that inverse squared.
- 6:03Speaker 1: Formula, which is really just another way of saying the
- 6:05Speaker 1: total deflection is the choice deflection plus the girder deflection.
- 6:09Speaker 2: Precisely, and when you're calculating these things, the guide points
- 6:14Speaker 2: out two really critical adjustments that a lot of young
- 6:18Speaker 2: engineers miss. First, for amendment of inertia, you should always
- 6:22Speaker 2: assume composite action.
- 6:24Speaker 1: Even without structural sheer connectors.
- 6:27Speaker 2: Even without them for dynamic loads, the friction and any
- 6:31Speaker 2: tack welds are usually enough to make the slab and
- 6:33Speaker 2: beam work together.
- 6:34Speaker 1: And the second one is that adjustment for concrete. Why
- 6:37Speaker 1: does the guide say to use one point three five
- 6:40Speaker 1: times the normal modulus of elasticity for concrete?
- 6:43Speaker 2: That thirty five percent bump is crucial. See under a
- 6:46Speaker 2: rapid dynamic load that a footstep, the concrete doesn't have
- 6:49Speaker 2: time to creep or develop the microcracks it would under
- 6:52Speaker 2: a long term static load.
- 6:53Speaker 1: Ah, so its instantaneous stiffness is just higher, it's higher.
- 6:57Speaker 2: So using one point three to five ec gives you
- 6:59Speaker 2: a much more accurate picture of how the floor will
- 7:01Speaker 2: actually behave under vibration.
- 7:03Speaker 1: That's a great physical insight. And for the weight, the
- 7:05Speaker 1: W that causes all this deflection, we need to be realistic, right,
- 7:08Speaker 1: we're not using our conservative design live loads.
- 7:10Speaker 2: No, definitely not. If you use overly conservative loads here,
- 7:14Speaker 2: you'll calculate an artificially low frequency and you might end
- 7:17Speaker 2: up overdesigning the floor. The guide recommends something like eleven
- 7:21Speaker 2: pubs for offices and maybe six pfs for residential areas,
- 7:25Speaker 2: just actual everyday loads.
- 7:27Speaker 1: Okay, let's move to section three practical application. Let's talk
- 7:32Speaker 1: about walking. We have a formula, but we need to
- 7:35Speaker 1: define W the effective panel weight.
- 7:38Speaker 2: Right, and W is the total mass it's actually participating
- 7:41Speaker 2: in the vibration. It's calculated from the weight per area
- 7:44Speaker 2: the span in this thing called the effective width, and
- 7:47Speaker 2: that's where you really need some design intuition.
- 7:49Speaker 1: Let's talk about a classic design headache then, mezzanine floor
- 7:52Speaker 1: edges or beams along an atrium. Why do those always
- 7:56Speaker 1: seem to have vibration problems.
- 7:58Speaker 2: It's all about that reduced effective mass that w an
- 8:01Speaker 2: interior beam when it vibrates, it drags a big area
- 8:04Speaker 2: of the slab along with it. You're effective with coefficient
- 8:07Speaker 2: might be.
- 8:07Speaker 1: Two, but at a free edge.
- 8:09Speaker 2: At a free edge there's much less slab to drag along.
- 8:12Speaker 2: The effective with coefficient alpha J can drop down to one.
- 8:15Speaker 2: It's half the participating mass.
- 8:17Speaker 1: I feel like a lot of engineers learn that the
- 8:19Speaker 1: hard way you design it. It's fine for strength, but
- 8:22Speaker 1: because it's only supporting half the mass of an interior beam,
- 8:25Speaker 1: it just feels like a trampoline.
- 8:27Speaker 2: That's spot on. The guide has an example four point
- 8:30Speaker 2: seven that shows this perfectly. A standard design fails with
- 8:33Speaker 2: something like zero point six three percent G when the
- 8:37Speaker 2: limit for an office is zero point five, and to
- 8:40Speaker 2: fix that small failure. You often have to massively stiffen
- 8:43Speaker 2: that edge member, sometimes a fifty percent increase in its
- 8:46Speaker 2: moment of inertia.
- 8:47Speaker 1: Wow. And the damping ratio beta, that's tied to all
- 8:50Speaker 1: the nonstructural stuff, right, the things that absorb energy.
- 8:53Speaker 2: Yes, an open floor plan or a footbridge has very
- 8:56Speaker 2: low damping. Maybe beta is point oh one. But an
- 8:59Speaker 2: office full of partitions, furniture, ceilings, all that stuff absorbs energy,
- 9:03Speaker 2: and you can get beta up to point oh five.
- 9:05Speaker 2: Those partitions are doing a real dynamic job for you.
- 9:08Speaker 1: We should also quickly mention open web joists. They're everywhere,
- 9:11Speaker 1: but they have their own unique issues they do.
- 9:14Speaker 2: The standard seats on those joists just aren't stiff enough
- 9:17Speaker 2: to give you full composite action with the girder they
- 9:20Speaker 2: sit on, So the guide makes you reduce the girder's
- 9:23Speaker 2: effective moment of inertia to account for that connection flexibility.
- 9:27Speaker 2: It's a crucial little detail.
- 9:29Speaker 1: Okay, let's shift gears. Section four rhythmic excitation. Now we're
- 9:34Speaker 1: talking about aerobics, dancing, big crowds, jumping. These loads are
- 9:38Speaker 1: way way more severe.
- 9:39Speaker 2: They are orders of magnitude more severe. The forces are
- 9:42Speaker 2: so large and so repetitive that you know, unlike with walking,
- 9:46Speaker 2: you can't really control the resonance just by adding a
- 9:48Speaker 2: bit of damping or mass. It's too extreme.
- 9:50Speaker 1: So the whole design philosophy has to change.
- 9:52Speaker 2: It completely shifts. It goes from control to resonance avoidance, so.
- 9:56Speaker 1: You're not trying to manage it anymore, you're just trying
- 9:58Speaker 1: to get out of its way exactly.
- 10:00Speaker 2: The goal is to make sure your fundamental natural frequency
- 10:03Speaker 2: fd N is safely above the forcing frequency of the
- 10:07Speaker 2: highest harmonic that could cause trouble. Think about aerobics, the
- 10:10Speaker 2: step frequency is maybe one and a half to three.
- 10:13Speaker 1: Herts, but the harmonics go higher.
- 10:15Speaker 2: Right They generate significant force up to the third harmonic,
- 10:20Speaker 2: So that means you have to avoid resonans all the
- 10:22Speaker 2: way up to nine herts.
- 10:23Speaker 1: So what does a place like a gem need for
- 10:26Speaker 1: a minimum frequency.
- 10:27Speaker 2: Then, for serious jumping exercises, the bar is set really high.
- 10:31Speaker 2: You need an FN of about nine hertz. If you
- 10:35Speaker 2: have say a dining area next to a dance floor,
- 10:37Speaker 2: it's a bit less sensitive. The requirement there is around
- 10:40Speaker 2: seven point three herts. But these are absolute minimums to
- 10:44Speaker 2: prevent people from feeling really uncomfortable.
- 10:46Speaker 1: The guide also mentioned something interesting. For tall buildings, the
- 10:50Speaker 1: columns themselves can cause problems.
- 10:52Speaker 2: Yes, because of axial shortening, the column acts like a
- 10:56Speaker 2: big vertical spring, and for very cold buildings fifteen stories
- 10:59Speaker 2: are more, the column's own natural frequency can be low
- 11:02Speaker 2: enough to actually resonate with the second harmonic.
- 11:04Speaker 1: Of jumping, and then it would transmit that vibraction vertically
- 11:07Speaker 1: through the whole building, which is a.
- 11:09Speaker 2: Huge problem, a very difficult transmission path to fix after
- 11:12Speaker 2: the fact.
- 11:13Speaker 1: Okay, section five another big shift. We're moving away from
- 11:17Speaker 1: human comfort and into high tech function designing for sensitive equipment.
- 11:22Speaker 1: You can't use a half percent G limit for an
- 11:25Speaker 1: electron microscope.
- 11:26Speaker 2: No, you can't. Here the criteria change completely. We stop
- 11:30Speaker 2: talking about acceleration and we start talking about vibrational velocity
- 11:34Speaker 2: V usually micrometers per second.
- 11:36Speaker 1: And why of velocity.
- 11:38Speaker 2: Because for most sensitive equipment, the maximum allowable velocity stays
- 11:42Speaker 2: pretty constant across the frequency range we care about, and
- 11:45Speaker 2: the range is huge. General computers might allow two hundred
- 11:49Speaker 2: micrometers per second, but high end microchip manufacturing they might
- 11:53Speaker 2: demand a limit as low as three.
- 11:55Speaker 1: So the design rule directly links the floor's flexibility to
- 11:58Speaker 1: that velocity limit. Can you rate down the physics of
- 12:00Speaker 1: that for us, because it seems like the stiffness requirements
- 12:03Speaker 1: can get out of hand really fast.
- 12:04Speaker 2: They can. It's a quadratic relationship. Velocity V is proportional
- 12:10Speaker 2: to the square root of the floor's flexibility, which means
- 12:12Speaker 2: flexibility is proportional to V squared.
- 12:14Speaker 1: Wait, so if you need to cut the allowable velocity
- 12:17Speaker 1: in half.
- 12:17Speaker 2: If you cut V in half, say from fifty down
- 12:21Speaker 2: to twenty five, you have to reduce the flexibility by
- 12:23Speaker 2: a factor of one half squared, which is one fourth.
- 12:26Speaker 1: So you have to make the floor four times stiffer.
- 12:29Speaker 2: Four times stiffer for sensitive equipment. Stiffness is absolutely king,
- 12:34Speaker 2: There's no getting around it.
- 12:35Speaker 1: So if you can't just over design the entire floor,
- 12:38Speaker 1: what are the best mitigation strategies?
- 12:40Speaker 2: Location? Location, location, Put the sensitive gear near columns, the
- 12:44Speaker 2: stiffest points, and keep it away from busy corridors. You
- 12:47Speaker 2: can use isolation devices, but they only really work if
- 12:50Speaker 2: the structure they're sitting on is already pretty stiff and.
- 12:53Speaker 1: The guide gives a pretty serious warning about raised floors.
- 12:56Speaker 2: A major warning. Never put sensitive equipment on a raised
- 12:59Speaker 2: floor or where people walk. Unless you provide rigid pedestals
- 13:02Speaker 2: that go directly to the structural slab, that raised floor
- 13:06Speaker 2: is just another flexible system, another trampoline that will amplify
- 13:09Speaker 2: the motion.
- 13:10Speaker 1: Okay, finally section six. The worst case scenario. The floor
- 13:14Speaker 1: is built and it vibrates. What are the options for
- 13:16Speaker 1: evaluation and well fixing it?
- 13:19Speaker 2: The evaluation starts with just observing performance tests, but for
- 13:24Speaker 2: a real professional assessment, you're doing vibration measurements, usually heel
- 13:29Speaker 2: drop tests with accelerometers to capture the real FN, the
- 13:32Speaker 2: damping and the mode shape.
- 13:34Speaker 1: Of the floor. And if you have to retrofit it,
- 13:36Speaker 1: what's the most effective fix?
- 13:38Speaker 2: Adding a new column is always the best, but it's
- 13:40Speaker 2: rarely practical. So if you need to stiffen an existing member,
- 13:44Speaker 2: welding or clamping a queen post haangar to the bottom
- 13:47Speaker 2: flange is incredibly effective provided you have a ceiling space. Yeah,
- 13:51Speaker 2: it adds a ton of stiffness.
- 13:53Speaker 1: And what are the retrofits that people try that just
- 13:56Speaker 1: don't work?
- 13:57Speaker 2: Just welding some cover plates or rods to the bottom
- 13:59Speaker 2: of an open waub joist is usually waste of time.
- 14:01Speaker 2: It might add a little flexial stiffness, But it does
- 14:04Speaker 2: nothing to address the deformation from sheer and joint eccentricity,
- 14:08Speaker 2: which is where most of the problem is.
- 14:09Speaker 1: With choists.
- 14:10Speaker 2: You also have passive control options like tuned mass dampers
- 14:14Speaker 2: or TMDs.
- 14:15Speaker 1: Right, these secondary masses.
- 14:16Speaker 2: Yeah, they can be amazingly effective, sometimes cutting acceleration by
- 14:20Speaker 2: a factor of ten. But and this is a big butt.
- 14:24Speaker 2: The only work if the floor has one single dominant
- 14:27Speaker 2: mode of vibration, and they're useless for rhythmic activities that
- 14:31Speaker 2: are off resonance.
- 14:32Speaker 1: And what about that weird wave like vibration you can
- 14:35Speaker 1: get in big open plan offices with lots of identical joists.
- 14:39Speaker 2: Ah, the beating decay. That's a problem of symmetry. All
- 14:43Speaker 2: those identical joys transmit the vibration like a wave. The
- 14:46Speaker 2: fix is to break the symmetry periodically, change the stiffness
- 14:50Speaker 2: or the spacing of the joists. Maybe make every third
- 14:52Speaker 2: day fifty percent stiffer. That'll inter the wave and stop
- 14:55Speaker 2: the transmission.
- 14:56Speaker 1: So after all this, what does it all mean for
- 14:58Speaker 1: you the designer?
- 14:59Speaker 2: It means that serviceability design is complex. You have to
- 15:03Speaker 2: think beyond just strength and stability. You have to directly
- 15:06Speaker 2: consider how people perceive motion and what equipment needs to function.
- 15:10Speaker 2: It's about matching the specific dynamic load walking versus rhythmic
- 15:13Speaker 2: to the specific tolerance, whether that's an acceleration limit for
- 15:16Speaker 2: people or a velocity limit for a machine.
- 15:18Speaker 1: You really have to embrace dynamic analysis for what seemed
- 15:22Speaker 1: like everyday situations you do.
- 15:24Speaker 2: Vibration analysis really is about the user experience. It's amazing
- 15:28Speaker 2: how a small change in frequency can change absolutely everything.
- 15:32Speaker 1: Okay, now for a quick challenge for you listening. Imagine
- 15:35Speaker 1: a lightweight office floor with a fundamental natural frequency FN
- 15:38Speaker 1: of five hurtz. A new tenant wants to bring in
- 15:41Speaker 1: sensitive lab equipment that requires the floor to meet a
- 15:44Speaker 1: vibrational velocity limit V that is one third of what
- 15:48Speaker 1: the current design allows. By what approximate factor must you
- 15:52Speaker 1: increase the floor's stiffness to satisfy that new requirement.
- 15:55Speaker 2: And here's a final provocative thought to leave you with.
- 15:58Speaker 2: We know that rhythmic activities like aerobics require the floors
- 16:01Speaker 2: fn to be well above the highest forcing harmonic maybe
- 16:05Speaker 2: nine hertz. But thinking about how columns is a very
- 16:08Speaker 2: tall building also have their own low natural frequencies from
- 16:11Speaker 2: axial shortening. What kind of unexpected resonance problem might you
- 16:15Speaker 2: run into if you decided to put a gym on
- 16:17Speaker 2: a very very high floor.