Latest / Civil Engineering Made Simple / Façade Attachments to Steel-Framed Buildings
Transcript
- 0:00Speaker 1: If you've ever driven into a multi story parking garage,
- 0:02Speaker 1: you probably didn't think twice about the engineering marvel supporting
- 0:06Speaker 1: your vehicle. But for civil engineers, these buildings are uniquely punishing.
- 0:11Speaker 2: They really are.
- 0:12Speaker 1: We're talking about highly specialized open deck structures that face
- 0:16Speaker 1: constant dynamic loads, relentless freeze thaw cycles, and well the
- 0:21Speaker 1: ultimate structural enemy, massive volumes of de icing salts.
- 0:25Speaker 2: It's an environment that seems almost designed to destroy concrete
- 0:28Speaker 2: and corrode steel. It truly is a recipe for accelerated deterioration.
- 0:33Speaker 1: So the fundamental challenge for designers is just how to
- 0:36Speaker 1: make it last?
- 0:37Speaker 2: Pretty much? How do you design for long term di
- 0:39Speaker 2: abiity in this extremely harsh setting, knowing that the structure's
- 0:43Speaker 2: life cycle cost is governed almost entirely by how well
- 0:46Speaker 2: it resists that environmental stress.
- 0:47Speaker 1: Okay, let's unpack this. We're doing a deep dive into
- 0:50Speaker 1: the blueprint for success here, drawing heavily from the industry's
- 0:53Speaker 1: gold standard, the AISC's Design Guide eighteen Steel framed open deck.
- 0:58Speaker 2: Parking Structures Fantastic Resource.
- 1:01Speaker 1: Our mission today is to distill the critical technical knowledge
- 1:05Speaker 1: you need to optimize these structures we want to cut
- 1:08Speaker 1: through the noise and get right to the decisions that
- 1:10Speaker 1: separate a high maintenance disaster from a decades long performer.
- 1:15Speaker 2: And what's fascinating is this shift here. Historically these were
- 1:19Speaker 2: concrete buildings through and through, but the move towards steel
- 1:24Speaker 2: framing has really accelerated.
- 1:26Speaker 1: And why is that why?
- 1:27Speaker 2: Steal well steel offers significant advantages. Now you're looking at
- 1:31Speaker 2: lower overall construction costs, much more rapid erection and long
- 1:36Speaker 2: term durability when it's properly protected.
- 1:38Speaker 1: I'd imagine the weight is a big factor.
- 1:40Speaker 2: Too, Oh, absolutely, Perhaps the most compelling reason is weight reduction.
- 1:43Speaker 2: Steel structures are often twenty percent lighter than their concrete equivalents.
- 1:48Speaker 1: That's a massive difference, especially if you're building in a
- 1:50Speaker 1: city with poor soil conditions. That kind of weight reduction
- 1:54Speaker 1: cuts costs right from the ground up exactly.
- 1:57Speaker 2: And that lighter system also inherently provides enhanced seismic performance,
- 2:01Speaker 2: which is a major benefit for stability and safety, especially
- 2:04Speaker 2: in active zones. It's an efficiency win win.
- 2:07Speaker 1: So let's transition into planning from a structural engineer's perspective.
- 2:12Speaker 1: What are the core components you're juggling.
- 2:14Speaker 2: The guide breaks it down into major focus areas. You're
- 2:17Speaker 2: looking at the deck systems. That's the concrete driving surface,
- 2:20Speaker 2: the steel framing systems that support them, fire protection, barriers
- 2:24Speaker 2: and facades of course, stairs and elevators, corrosion protection, and
- 2:29Speaker 2: finally a plan for structural maintenance.
- 2:32Speaker 1: Before we dig into the concrete and skill, we have
- 2:34Speaker 1: to talk about the legal environment. What are some of
- 2:37Speaker 1: the key code considerations that maybe catch engineers by surprise.
- 2:41Speaker 2: The biggest one, I think involves fire protection. Open deck
- 2:46Speaker 2: structures have a huge advantage here. The key exemption is
- 2:49Speaker 2: that structural steel members and an open deck parking structure
- 2:52Speaker 2: less than seventy five feet in height generally do not
- 2:55Speaker 2: require fire protection. That saves a substantial amount of time
- 2:58Speaker 2: and cost.
- 2:59Speaker 1: That's a great initial cost saver. But what's the fine
- 3:01Speaker 1: print on open deck? There's always fine print there is.
- 3:04Speaker 2: It's specific any point on the deck must be within
- 3:08Speaker 2: two hundred feet of an open side. And critically, that
- 3:11Speaker 2: seventy five foot height limit is measured to the deck
- 3:14Speaker 2: surface of the top parking tier, not to the top
- 3:16Speaker 2: of some decorative facade.
- 3:18Speaker 1: Ah, that's a key distinction. Knowing that specific measurement is
- 3:22Speaker 1: vital it is and beyond fire ratings, what about accessibility?
- 3:26Speaker 1: The EIGHTA guidelines must impact the geometry pretty heavily.
- 3:30Speaker 2: Absolutely, when planning the layout, you have to incorporate accessible spaces.
- 3:34Speaker 2: They need to be at least eight feet wide with
- 3:36Speaker 2: an adjacent five foot accessible aisle.
- 3:38Speaker 1: And van spaces are even more demanding.
- 3:41Speaker 2: Right for van accessible spaces, the vertical clearance needs to
- 3:44Speaker 2: jump up to a minimum of eight feet two inches
- 3:46Speaker 2: and they need a full eight foot wide aisle.
- 3:48Speaker 1: Then there are the ramps. If they handle pedestrians and vehicles,
- 3:51Speaker 1: the slope is tightly.
- 3:53Speaker 2: Controlled precisely for user safety. Those ramps shouldn't exceed a
- 3:57Speaker 2: five percent slope, with six percent being the app maximum.
- 4:00Speaker 2: In some conditions, that small number dictates your whole geometry.
- 4:04Speaker 1: Okay, let's talk loads. The code gives US minimums fifty
- 4:08Speaker 1: psf uniform live load and a two thousand pounds concentrated load.
- 4:13Speaker 1: As a young engineer, should I just design for those?
- 4:16Speaker 2: This brings up a critical point about optimization. Those are
- 4:19Speaker 2: the legal minimums, but if you actually look at the
- 4:21Speaker 2: realistic loading, it's often closer to thirty to thirty five psf.
- 4:26Speaker 1: So what do you do?
- 4:27Speaker 2: Well, you must always satisfy the code, but you also
- 4:29Speaker 2: have to check the realistic vehicle loading. You know, consider
- 4:33Speaker 2: rolling loads or pattern loading, the arrangement of cars that
- 4:36Speaker 2: creates the absolute worst case scenario.
- 4:38Speaker 1: And you design for whichever is more conservative.
- 4:41Speaker 2: You got it. It often means the concentrated load from
- 4:43Speaker 2: a heavy vehicle is what really governs the design, not
- 4:46Speaker 2: the uniform load.
- 4:47Speaker 1: Right, you can't rely on the empty spaces helping you
- 4:49Speaker 1: out exactly. Let's move to the real durability battleground, the
- 4:53Speaker 1: deck systems. This is where the life cycle cost is
- 4:56Speaker 1: one or lost. What is the molecular villain here?
- 5:00Speaker 2: It's chlorid contamination from de icing salts. This is the
- 5:03Speaker 2: single biggest threat to the integrity of the entire facility.
- 5:06Speaker 1: And what does it do? Exactly?
- 5:08Speaker 2: Once chlorides penetrate the concrete, they initiate corrosion of the rebar.
- 5:12Speaker 2: And here's the frightening statistic. It only takes abou zero
- 5:15Speaker 2: point two percent acid soluble chloride content to kick off
- 5:19Speaker 2: that process.
- 5:20Speaker 1: That sounds like a tiny amount. What happens when that
- 5:22Speaker 1: corrosion starts?
- 5:24Speaker 2: When steel rests, it expands. We are talking about internal
- 5:28Speaker 2: pressures of up to fifty thousand psi being generated inside.
- 5:32Speaker 1: The concrete fifty thousand ci.
- 5:34Speaker 2: Yeah, that isn't just a number, it's the pressure that
- 5:37Speaker 2: literally forces the concrete to fracture and pop off, creating spawling.
- 5:41Speaker 2: So if the steel is expanding with that force, crack
- 5:44Speaker 2: control has to be the engineer's absolute highest priority.
- 5:47Speaker 1: So if crack control is everything, let's compare the three
- 5:49Speaker 1: main deck types, starting with the standard cast in place
- 5:52Speaker 1: conventionally reinforced concretep.
- 5:55Speaker 2: CIP is the most traditional method. The drawback is that
- 5:58Speaker 2: it's inherently prone to cracking on the ten inside of
- 6:00Speaker 2: the slab.
- 6:01Speaker 1: So how do you fight that?
- 6:02Speaker 2: With street control? You need a minimum concrete strength of
- 6:06Speaker 2: forty five hundred psi, a very low water to cement
- 6:09Speaker 2: ratiomax point four, and critically, a minimum of one and
- 6:13Speaker 2: a half inches of clear cover for the top layer
- 6:15Speaker 2: of rebar, plus a full seven days of wick cure.
- 6:18Speaker 1: What happens if I'm a contractor in a rush and
- 6:21Speaker 1: I only provide one inch of cover.
- 6:23Speaker 2: That's the exact reason for so many early failures. That
- 6:26Speaker 2: half inch difference can dramatically reduce the time it takes
- 6:29Speaker 2: for chlorides to reach the steel, effectively cutting the decks
- 6:32Speaker 2: durable life span in half. That cover is your first
- 6:36Speaker 2: and best defense.
- 6:37Speaker 1: And for protecting a rebar itself.
- 6:39Speaker 2: You have several options. Epoxy coating is common or galvanizing.
- 6:43Speaker 2: You can also use corrosion inhibiting ad mixtures like calcium
- 6:46Speaker 2: nitrite or silica fume directly in the mix.
- 6:48Speaker 1: Okay, now let's talk about the heavy hitters, starting with
- 6:50Speaker 1: post tension slabs or pt.
- 6:53Speaker 2: PT slabs are widely considered the most durable deck system
- 6:56Speaker 2: for all climate zones, even with heavy salt use.
- 6:58Speaker 1: And why is that.
- 6:59Speaker 2: It's because the steel strands are tensioned after the concrete sets.
- 7:03Speaker 2: This action puts the entire slab into compression, and if
- 7:06Speaker 2: the slab is always in compression, cracking is minimized.
- 7:09Speaker 1: That compressive force is a fantastic defense mechanism. What's a
- 7:14Speaker 1: key design metric here?
- 7:15Speaker 2: A great rule of thumb for preliminary sizing is the
- 7:18Speaker 2: span to death ratio. It's typically around forty five. The
- 7:21Speaker 2: trade off is a slightly higher initial cost and the
- 7:25Speaker 2: need for very specialized.
- 7:26Speaker 1: Labor and finally, precast double tees. They offer speed, but
- 7:30Speaker 1: there's a catch.
- 7:31Speaker 2: A major maintenance caveat. Yes, double t's are a great
- 7:34Speaker 2: long span system, often up to sixty five feet, and
- 7:37Speaker 2: they use high quality, factory controlled concrete. Erection is very rapid,
- 7:42Speaker 2: but the joints. But the joints. The structure relies on
- 7:45Speaker 2: joints between every single tea and these become the weak
- 7:48Speaker 2: points where water and chlorides are guaranteed to penetrate. They
- 7:50Speaker 2: have to be meticulously sealed and replaced, typically every six
- 7:53Speaker 2: to eight years.
- 7:54Speaker 1: So with all these systems, drainage is obviously critical.
- 7:57Speaker 2: How important is the slope It's absolutelyotential. The design guide
- 8:01Speaker 2: suggests a minimum of one eighth inch per foot, but
- 8:04Speaker 2: a quarter inch per foot is strongly preferred. You have
- 8:07Speaker 2: to have positive drainage to minimize any ponding and quickly.
- 8:10Speaker 1: On topical protection. The difference between a sealer and a membrane, it's.
- 8:13Speaker 2: A cost benefit decision. A sealer is light, breathable, good
- 8:17Speaker 2: for uncracked concrete. A membrane, on the other hand, is
- 8:21Speaker 2: a heavy waterproof system, often required over occupied space, but
- 8:26Speaker 2: be warned membranes can cost four to five times more.
- 8:30Speaker 1: Let's transition to the steel framing systems. Since the frame
- 8:33Speaker 1: must work with the deck, what geometry is most economical.
- 8:36Speaker 2: For standalone garages long spans typically fifty five to sixty
- 8:40Speaker 2: five feet using standard AsTMa nine nine to two wide Flan
- 8:44Speaker 2: shapes are generally the most cost effective. It minimizes columns,
- 8:49Speaker 2: which is great.
- 8:49Speaker 1: For barking and when do we use composite action.
- 8:51Speaker 2: Composite beams where the slab and beam act as one unit,
- 8:54Speaker 2: are used for all cast in place slabs, but this
- 8:57Speaker 2: is precluded when you use precast double t's. There's just
- 9:00Speaker 2: no effective way to connect them to get that composite behavior.
- 9:03Speaker 1: For those PT flubs you mentioned, the steel interaction is specialized.
- 9:06Speaker 1: How does that post tensioning force affect the steel beams.
- 9:09Speaker 2: It's primarily a beneficial compressive force on the composite member.
- 9:12Speaker 2: It only causes a small stress increase, maybe three percent
- 9:15Speaker 2: in the main steel beams. The critical thing to remember
- 9:18Speaker 2: is crack restraint, meaning you have to limit the number
- 9:21Speaker 2: of beams spanning in the direction of the post tensioning.
- 9:25Speaker 2: Too much restraint from the steel and the concrete will crack.
- 9:28Speaker 1: I always find the shoring debate interesting. Short or unshored
- 9:31Speaker 1: construction for durability.
- 9:34Speaker 2: Unshored composite construction is often preferred with the beams cambered
- 9:38Speaker 2: a bit. Not because of costs, no, because of durability.
- 9:42Speaker 2: Perfectly level floors aren't critical, and avoiding shoring can actually
- 9:46Speaker 2: reduce cracking in the concrete deck over the girders. Again,
- 9:50Speaker 2: anything that reduces cracking is a good thing.
- 9:53Speaker 1: Okay. If we connect this to the bigger picture, vertical
- 9:55Speaker 1: framing is where thermal forces really come into play. This
- 9:59Speaker 1: is unique to open structures.
- 10:01Speaker 2: Absolutely, this is a critical insight. Because the structure is open,
- 10:05Speaker 2: it's not dimensionally stable. In northern States, you can see
- 10:08Speaker 2: a one hundred degree fahrenheit temperature variation through the year.
- 10:12Speaker 2: This causes significant lengthening and shortening.
- 10:15Speaker 1: And that movement creates a fatal flaw if the bracing
- 10:18Speaker 1: is in the wrong spot. Here's where it gets really interesting.
- 10:21Speaker 2: Yes, because of these length changes the brace bay or
- 10:26Speaker 2: shear wall, your lateral system must be located near the
- 10:30Speaker 2: center of mass of the structure.
- 10:31Speaker 1: So what's the cardinal sin the structural engineer must avoid.
- 10:36Speaker 2: You must never locate the latter bracing at the ends
- 10:38Speaker 2: of the building. Doing that tries to restrain the structure's
- 10:42Speaker 2: natural movement, which risks buckling or tension. Failure in the
- 10:46Speaker 2: braces and just as bad massive cracking in the deck.
- 10:50Speaker 1: The fixed point should be in the middle, letting it
- 10:52Speaker 1: breathe essentially.
- 10:53Speaker 2: Exactly, let it expand and contract symmetrically from the center.
- 10:56Speaker 1: And if you're using concrete shear walls around an elevator.
- 10:59Speaker 2: Core, they are very rigid, so they must be physically
- 11:02Speaker 2: isolated from the decks lab you have to detail that
- 11:05Speaker 2: connection to permit vertical deflection. Failure to do that was
- 11:08Speaker 2: a really common cause of early garage failures.
- 11:11Speaker 1: Let's talk about protecting the steel frame itself. What are
- 11:14Speaker 1: the best strategies.
- 11:15Speaker 2: You have two dominant high performance options, industrial coding systems,
- 11:20Speaker 2: paint basically or hot dip galvanizing with paint.
- 11:23Speaker 1: I imagine the application is key, it's everything.
- 11:26Speaker 2: A typical system is three coats zinc rich primer, an
- 11:30Speaker 2: epoxy intermediate, and a polyurethane top coat, but its long
- 11:33Speaker 2: term performance is critically dependent on surface preparation.
- 11:37Speaker 1: What level of prepper are we talking about?
- 11:39Speaker 2: You need commercial blast cleaning SSPCSP six or even near
- 11:43Speaker 2: white SP ten. If you fail to prep the surface
- 11:47Speaker 2: to that level, the coating will fail and that expensive system,
- 11:51Speaker 2: which can be ten to twenty per tent of your
- 11:52Speaker 2: steel cost is just a wasted investment.
- 11:55Speaker 1: What about galvanizing as an alternative.
- 11:57Speaker 2: Hot dip Galvanizing is gaining ground. It provides a unique
- 12:01Speaker 2: metallurgical bond and sacrificial protection. It's actually harder and thicker
- 12:05Speaker 2: at corners and edges, which are weak spots for paint,
- 12:08Speaker 2: and the lifespan you're looking at a thirty year plus
- 12:10Speaker 2: life and it's highly competitive with high performance paint systems,
- 12:13Speaker 2: especially where chloride exposure is relentless.
- 12:16Speaker 1: We should also mention the one material to avoid.
- 12:18Speaker 2: Yes weathering steel AsTMa five eighty eight. It must be avoided.
- 12:22Speaker 2: It performs very poorly near chlorides, and the restaurantoff stains
- 12:26Speaker 2: everything to concrete, the cars. It's a liability nightmare.
- 12:29Speaker 1: Finally, let's look at the pumimit of barriers, the last
- 12:32Speaker 1: line of defense.
- 12:33Speaker 2: They need to be incredibly robust. Code requires them to
- 12:37Speaker 2: withstand a ten thousand pound ultimate point load applied eighteen
- 12:41Speaker 2: inches above the surface.
- 12:42Speaker 1: Table barriers are common for.
- 12:44Speaker 2: That, very common and efficient. They convert that impact load
- 12:47Speaker 2: into tension, but designing them is tricky. How So it
- 12:51Speaker 2: requires iterative calculations to balance deflection and tension. And here's
- 12:55Speaker 2: a critical warning. If you apply too much pretensioning force
- 12:59Speaker 2: to the cable, you can easily overload small columns, particularly
- 13:03Speaker 2: corner columns.
- 13:04Speaker 1: And one final check on the facade itself.
- 13:07Speaker 2: You have to maintain the code required openness, typically at
- 13:10Speaker 2: least twenty percent of the total perimeter wall area. If
- 13:13Speaker 2: you enclose it too much, you trigger requirements for mechanical
- 13:16Speaker 2: ventilation and you can lose that fire protection exception.
- 13:19Speaker 1: So what does this all mean for the engineer. This
- 13:22Speaker 1: is really an exercise in balancing initial cost against decades
- 13:25Speaker 1: of maintenance.
- 13:26Speaker 2: That's the whole game. The critical decisions choosing the right
- 13:29Speaker 2: deck for the climate, prioritizing drainage, isolating your bracing, and
- 13:33Speaker 2: selecting high performance corrosion protection, those are your keys to success.
- 13:38Speaker 1: To reinforce that, let's leave everyone with a quick calculation exercise.
- 13:41Speaker 1: Imagine you were designing a steel framed parking structure with
- 13:45Speaker 1: a cast in place post tension deck.
- 13:47Speaker 2: Okay, and your desired clear span between beams is twenty
- 13:52Speaker 2: two point five feet. The question is what is the
- 13:55Speaker 2: required minimum slab thickness in inches? Assuming you use the
- 13:59Speaker 2: industry standard span to depth ratio of forty five.
- 14:03Speaker 1: That formula is pretty straightforward. It's the span in feet
- 14:05Speaker 1: times twelve. Then you divide that by the span to
- 14:08Speaker 1: depth ratio of forty five.
- 14:09Speaker 2: Correct. So twenty two point five feet multiplied by twelve
- 14:12Speaker 2: inches per foot divided by forty five yields six point
- 14:15Speaker 2: zero inches. A six inch slab is your minimum required
- 14:19Speaker 2: thickness for that PT system.
- 14:20Speaker 1: And here is a final provocative thought to leave you
- 14:23Speaker 1: with one that really underscores everything we've discussed. The durability
- 14:26Speaker 1: of that expensive steel frame rests entirely on the integrity
- 14:29Speaker 1: of the concrete.
- 14:30Speaker 2: Deck above it. It's a simple truth.
- 14:32Speaker 1: Therefore, spending an extra few dollars per square foot initially
- 14:35Speaker 1: on premium concrete using a low water to cement ratio
- 14:39Speaker 1: proper curing good sealers that isn't just a material cost.
- 14:44Speaker 1: It is the lowest cost, most effective insurance policy you
- 14:47Speaker 1: can buy against decades of expensive steel corrosion maintenance.
- 14:49Speaker 2: Below a great reminder that in structural design, the best
- 14:53Speaker 2: solution is often the one that buys you time.
- 14:55Speaker 1: Absolutely thanks for joining us for the deep dove. We'll
- 14:57Speaker 1: see you next time.