- 0:00Speaker 1: Welcome to the deep dive. Today. We're strapping on our
- 0:03Speaker 1: hard hats and getting right into the decisions that well,
- 0:06Speaker 1: that really define world class steel design.
- 0:09Speaker 2: That's right, We're not just here to talk about code minimums.
- 0:12Speaker 2: We're going to explore the principles that make a building
- 0:14Speaker 2: genuinely economical.
- 0:16Speaker 1: And efficient and you could even say elegant. Our goal
- 0:21Speaker 1: today is pretty.
- 0:22Speaker 2: Focused, right, yeah, laser focused. We want to pull out
- 0:25Speaker 2: the practical, actionable rules from our source material, which is
- 0:29Speaker 2: heavily based on the AISC Design Guide five.
- 0:33Speaker 1: So these are the key insights that an engineering student
- 0:36Speaker 1: or a young professional really needs to know, the things
- 0:38Speaker 1: that help you deliver the most.
- 0:40Speaker 2: Value exactly, and that whole journey toward value. It doesn't
- 0:43Speaker 2: start with a calculator. It starts with a concept.
- 0:45Speaker 1: Okay, what's the concept.
- 0:46Speaker 2: The foundational principle for an economical design is to minimize
- 0:49Speaker 2: the number of fabricated and erected pieces period.
- 0:53Speaker 1: So it's not the raw weight of the steel that's
- 0:54Speaker 1: the main driver, not at all.
- 0:56Speaker 2: It's the labor, the cutting, the welding, the detailing, the hoisting,
- 1:00Speaker 2: what the costs are.
- 1:01Speaker 1: Which means you want to avoid complex connections like rigid
- 1:04Speaker 1: moment frames if you can, you'd rather stick with simple
- 1:07Speaker 1: sheer connections.
- 1:08Speaker 2: Precisely, And that same thinking applies to the material itself.
- 1:12Speaker 2: You've got this choice between say, mild steel that's thirty
- 1:15Speaker 2: six KC and high strength fifty KC steel.
- 1:19Speaker 1: And the assumption most people would make is that stronger
- 1:21Speaker 1: steel costs more. But that's not always the case, is
- 1:24Speaker 1: it not.
- 1:24Speaker 2: When you look at the price to strength ratio for
- 1:27Speaker 2: fifty KC steel beams, that ratio is about twenty five
- 1:32Speaker 2: percent lower than thirty.
- 1:33Speaker 1: Sixty C twenty five percent.
- 1:35Speaker 2: That's a huge difference, it is, And for columns it's
- 1:38Speaker 2: still ten to fifteen percent lower. This is where a
- 1:41Speaker 2: little bit of engineering knowledge gives you enormous leverage.
- 1:44Speaker 1: Can you give us a concrete example, put some numbers
- 1:46Speaker 1: on that.
- 1:46Speaker 2: Sure. Take a typical floor filler beam, a W twenty
- 1:49Speaker 2: one by forty four, made of thirty six KC steel
- 1:53Speaker 2: non composite. Its functional equivalent in a composite system is
- 1:57Speaker 2: a W sixteen by twenty six, a much lighter, much lighter,
- 2:00Speaker 2: but made of fifty c C steal. The material savings
- 2:04Speaker 2: alone are it's about three dollars and ninety cents per
- 2:06Speaker 2: linear foot, and.
- 2:07Speaker 1: When you multiplay that across an entire ten story building.
- 2:11Speaker 2: It becomes a massive number. You get better performance, less weight,
- 2:15Speaker 2: and a lower cost. It's a true win win.
- 2:18Speaker 1: Is there any time you'd still want to use the
- 2:20Speaker 1: old thirty six k s I steal?
- 2:22Speaker 2: Yeah, there is a small caveat for you know, small
- 2:27Speaker 2: non critical members, little angles channels. The economy swings back
- 2:31Speaker 2: to thirty six ca sie just because fabricators have tons
- 2:33Speaker 2: of bit in stock.
- 2:34Speaker 1: So for the small stuff, keep it simple.
- 2:36Speaker 2: And accessible exactly, don't over engineer it.
- 2:39Speaker 1: Okay, so we save money on the steel. Now let's
- 2:42Speaker 1: talk about adding long term value to the building itself.
- 2:44Speaker 1: This is where you start thinking more like a developer.
- 2:46Speaker 2: That's the mindset. The idea here is that larger bay
- 2:49Speaker 2: sizes and higher design live loads just make the building
- 2:52Speaker 2: more flexible, more serviceable.
- 2:54Speaker 1: And more rentable, which is what the owner cares about.
- 2:56Speaker 2: Right. A more robust building just ages better.
- 3:00Speaker 1: But I can already hear the young engineer saying, wait,
- 3:03Speaker 1: if I spec one hundred ps off live load instead
- 3:06Speaker 1: of the code minimum fifty, won't my columns and foundations
- 3:09Speaker 1: get huge?
- 3:10Speaker 2: And that leads us to what our sources call the
- 3:13Speaker 2: live load paradox.
- 3:14Speaker 1: It's fascinating right out for us.
- 3:17Speaker 2: Okay, let's imagine a ten story office building designed with ASD.
- 3:21Speaker 2: Scenario A uses it called a minimum fifty psf live
- 3:25Speaker 2: load plus twenty psf.
- 3:27Speaker 1: For partitions, got it, and scenario B.
- 3:29Speaker 2: Scenario B goes for a high capacity one hundred psf
- 3:33Speaker 2: live load with no separate partition allowance, so double the
- 3:37Speaker 2: floor load.
- 3:38Speaker 1: You'd expect the columns at the bottom to be much bigger.
- 3:40Speaker 2: You would, but building codes like ASC seven let you
- 3:44Speaker 2: take a live load reduction. The idea is that it's
- 3:47Speaker 2: nearly impossible for every single floor to be maxed out
- 3:50Speaker 2: at the same time.
- 3:51Speaker 1: Right, the statistical probability is tiny.
- 3:53Speaker 2: And that reduction can be up to sixty percent. When
- 3:56Speaker 2: you apply that maximum reduction, the final design load on
- 3:59Speaker 2: the column at the foundation is functionally identical, identical between
- 4:03Speaker 2: the fifty psf case and the hundred ps base identical.
- 4:05Speaker 2: So the heavy expensive things, columns, footings, they don't change.
- 4:09Speaker 2: Only the lighter, cheaper floor beams get a little bigger.
- 4:12Speaker 1: So what's the actual cost premium to do that upgrade?
- 4:14Speaker 2: It's astonishingly small, about nine cents per square foot. That's
- 4:19Speaker 2: less than one percent of the total structural cost.
- 4:22Speaker 1: For double the building's flexibility. That is an easy conversation
- 4:26Speaker 1: to have with an owner.
- 4:27Speaker 2: That's the definition of adding value.
- 4:29Speaker 1: And this connects right back to your first rule, minimize
- 4:32Speaker 1: the piece count. Let's see how bay size plays into that.
- 4:35Speaker 2: Okay, So compare a twenty five by twenty five foot
- 4:37Speaker 2: bay with a thirty x thirty foot bay. Okay, the
- 4:41Speaker 2: smaller bay needs one steel member for every one hundred
- 4:44Speaker 2: and twenty five square feet. The larger bay you jump
- 4:48Speaker 2: to one hundred and eighty square feet per member. Fewer
- 4:50Speaker 2: pieces to handle on site, which again is the priority.
- 4:55Speaker 2: And even though that thirty foot bay is a little
- 4:56Speaker 2: heavier per square foot, the total job cost is on
- 5:00Speaker 2: about three percent more.
- 5:01Speaker 1: And the fabricators and directors are happier.
- 5:03Speaker 2: They love it. Fewer pieces means their job is easier and.
- 5:06Speaker 1: Faster, and the source material has this great cautionary tale
- 5:09Speaker 1: about what happens when you forget that rule. Ah.
- 5:12Speaker 2: Yes, scheme three. This is where you take that nice
- 5:15Speaker 2: thirty by thirty bay and you try to save a
- 5:17Speaker 2: little material by adding an extra filler beam. You go
- 5:21Speaker 2: from three beams to.
- 5:22Speaker 1: Four, so the beams get lighter, but you have more.
- 5:24Speaker 2: Of them, a lot more of them, And that one
- 5:26Speaker 2: decision increases the total cost by ten percent with zero
- 5:29Speaker 2: improvement and performance none. The vibration rating is exactly the same.
- 5:34Speaker 1: The lesson couldn't be clearer. Labor dominates material in steel.
- 5:38Speaker 2: Construction every single time. Fewer heavier pieces beats more lighter pieces.
- 5:43Speaker 1: All right, let's move up to the floor system itself.
- 5:45Speaker 1: Composite construction, your standard metal deck, concrete fill, and steel
- 5:50Speaker 1: beams with headed studs.
- 5:51Speaker 2: Right, it's a high quality system, stiff, easy to fire proof.
- 5:56Speaker 2: And let's us talk about a really important design choice
- 5:59Speaker 2: ASD versus LRFD.
- 6:01Speaker 1: Allowable stress design versus load and resistance factor design. Yeah.
- 6:05Speaker 2: ASD is the older method. It's based on elastic analysis
- 6:08Speaker 2: and it's simple, but it often really underestimates the true
- 6:12Speaker 2: strength you can get from a composite section.
- 6:13Speaker 1: And that's where LRFD comes in.
- 6:15Speaker 2: LRFD is based on ultimate strength. It's a much more
- 6:18Speaker 2: accurate model of what actually happens at the connection between
- 6:22Speaker 2: the slab and the beam.
- 6:23Speaker 1: And it's not just more accurate, it can actually save money.
- 6:27Speaker 2: A lot of money for something with high loads like
- 6:31Speaker 2: a warehouse at two hundred and fifty psf Using LRFD
- 6:34Speaker 2: can save you about twenty percent in material cost compared
- 6:37Speaker 2: to ASD.
- 6:37Speaker 1: Twenty percent just from using a better analysis method.
- 6:40Speaker 2: It's a no brainer.
- 6:41Speaker 1: But what if the building's already up and a tenant
- 6:43Speaker 1: comes in and says, hey, I need to put a
- 6:45Speaker 1: bunch of heavy filing cabinets right here.
- 6:47Speaker 2: This is where composite construction is fantastic. You can get
- 6:49Speaker 2: a huge capacity boost just by welding a cover plate
- 6:52Speaker 2: to the bottom flange of the beam.
- 6:54Speaker 1: Why the bottom flange specifically, because.
- 6:56Speaker 2: The top flange is already doing its job working with
- 6:59Speaker 2: the concrete slab and compression, the bottom plange is intention
- 7:04Speaker 2: So by adding steel there you dramatically increase the beam's
- 7:08Speaker 2: moment capacity.
- 7:09Speaker 1: How dramatic are we talk, Well, take a.
- 7:11Speaker 2: W sixteen by thirty one beam, you add a six
- 7:14Speaker 2: by three quarter inch cover plate to it. That's maybe
- 7:17Speaker 2: a fifty percent increase in stell weight, but its live
- 7:21Speaker 2: load capacity can increase by nearly one hundred and fifty
- 7:24Speaker 2: percent under an LRFD analysis.
- 7:27Speaker 1: That's incredible leverage.
- 7:28Speaker 2: Yeah.
- 7:28Speaker 1: Now for the construction itself, there's always this debate shored
- 7:32Speaker 1: versus unshored slabs.
- 7:34Speaker 2: Right, unshored is simpler for the contractor, no temporary supports.
- 7:39Speaker 2: But the steel beams have to hold up all that
- 7:41Speaker 2: wet concrete by themselves before anything is composite, and you.
- 7:44Speaker 1: Have to account for ponding right the deflection.
- 7:46Speaker 2: You absolutely do. The wet concrete can pool in the
- 7:49Speaker 2: middle of the beams deflection, and you can end up
- 7:51Speaker 2: using ten percent more concrete than you plan for if
- 7:54Speaker 2: you're not careful.
- 7:55Speaker 1: So what's the advantage of shoring it?
- 7:56Speaker 2: Then with short construction you don't have to worry about
- 7:59Speaker 2: that wet load check. All your deflections are based on
- 8:01Speaker 2: the final much stiffer composite section.
- 8:04Speaker 1: But there's a critical detail the designer needs to add.
- 8:06Speaker 2: A very crucial detail. You must specify crack control reinforcement
- 8:11Speaker 2: in the slab right over the girders, because when those
- 8:15Speaker 2: shores come out, tension cracks are they're almost certain to
- 8:18Speaker 2: form that rebar is vital.
- 8:21Speaker 1: Okay, that makes sense. Let's shift from strength to serviceability.
- 8:24Speaker 1: Long term deflection.
- 8:25Speaker 2: Yeah, concrete creep and shrinkage. When you calculate that long
- 8:29Speaker 2: term deflection, the rule of thumb is to use a
- 8:32Speaker 2: reduced modulus of elasticity for the concrete. Basically you cut
- 8:35Speaker 2: the normal value in half.
- 8:37Speaker 1: And one last complication, yeah, under floor decks, the cellular decks, they're.
- 8:43Speaker 2: Great for office flexibility, but the trench headers, the access points,
- 8:47Speaker 2: they interrupt the composite action. And if you don't place
- 8:49Speaker 2: filler beams on both sides of that trench, the deck
- 8:52Speaker 2: there has to be designed as non composite.
- 8:54Speaker 1: And the result for the person walking on.
- 8:56Speaker 2: It, the floor can feel noticeably soft or spongy, not
- 9:02Speaker 2: good feeling.
- 9:02Speaker 1: Which brings us to our last major topic, and it's
- 9:04Speaker 1: a big one. Designing for lateral loads wind specifically.
- 9:08Speaker 2: Yes, for these load to medium rized buildings. This is
- 9:11Speaker 2: really where performance is defined. It's almost always about serviceability,
- 9:14Speaker 2: which means controlling drift.
- 9:16Speaker 1: And what's the industry standard target for that.
- 9:19Speaker 2: The long standing rule of thumb is keeping the deflection
- 9:22Speaker 2: over the height to about point zero zero zero two.
- 9:25Speaker 1: Five cave braced frames are a really common economical way
- 9:28Speaker 1: to do that. But we learned about a critical detail
- 9:31Speaker 1: in their geometry, a vital one.
- 9:33Speaker 2: It's all about the orientation of the apex of the cabrace.
- 9:36Speaker 1: So whether the VS points up or down.
- 9:38Speaker 2: Exactly, and you want it to point up. When the
- 9:39Speaker 2: apex points up, the diagonal loads go straight into the columns.
- 9:43Speaker 2: It basically eliminates story rotation and deflection from column strain
- 9:47Speaker 2: in that story.
- 9:48Speaker 1: And if you point the apex down.
- 9:50Speaker 2: The difference is it's huge. For a typical ten story frame,
- 9:54Speaker 2: changing the opex from up to down can increase your
- 9:57Speaker 2: maximum deflection by thirty five percent.
- 9:59Speaker 1: Thirty percent. That could be the entire difference between passing
- 10:02Speaker 1: and failing your drift check.
- 10:04Speaker 2: It often is. It's that big a deal.
- 10:05Speaker 1: Now, let's talk about unbraced frames using LRFD. The rule
- 10:10Speaker 1: for an economical design is to minimize the number of
- 10:13Speaker 1: moment frames right, maybe just on the perimeter.
- 10:15Speaker 2: Yes, And when you do that, there's a crucial stiffness
- 10:18Speaker 2: ratio you have to watch. It's the ratio of the
- 10:22Speaker 2: column stiffness to the girder stiffness I see over LC
- 10:27Speaker 2: divided by ig over LG.
- 10:29Speaker 1: And you have to keep that ratio below a certain number.
- 10:32Speaker 2: You want to keep it at or below one point five.
- 10:35Speaker 1: Why is one point five the magic number?
- 10:37Speaker 2: Because if you stay below one point five, you can
- 10:40Speaker 2: prove that the effect of length factor K for your
- 10:42Speaker 2: columns won't exceed one point five.
- 10:45Speaker 1: Okay, and what does that let you do?
- 10:46Speaker 2: It radically simplifies your P delta analysis. It means when
- 10:50Speaker 2: you're calculating the moment magnifier the B two factor, you
- 10:53Speaker 2: can just use K equals one point zero.
- 10:56Speaker 1: So just to unpack that for our listeners, P delta
- 10:58Speaker 1: is the secondary effect of gravity loads acting on the
- 11:02Speaker 1: display structure, and B two is the factor that accounts
- 11:04Speaker 1: for that.
- 11:05Speaker 2: Correct and being able to use K equals one simplifies
- 11:08Speaker 2: that calculation immensely. It stops you from having to oversize
- 11:11Speaker 2: your columns just to satisfy a stability check.
- 11:13Speaker 1: And this whole approach allows for what are called leaner
- 11:15Speaker 1: columns exactly.
- 11:17Speaker 2: These are interior gravity only columns. They don't resist the
- 11:21Speaker 2: lateral load themselves, but they rely on the stiff floor
- 11:24Speaker 2: diaphragm to get stability From the main moment frames. You
- 11:27Speaker 2: can design them with K equals one as well.
- 11:29Speaker 1: Okay, let's quickly touch on some of the more advanced
- 11:31Speaker 1: systems computers.
- 11:33Speaker 2: Let us use now right, you get into mixed systems.
- 11:36Speaker 2: Linked frames are a great example where you combine a
- 11:38Speaker 2: moment frame with a K braced frame. You get this
- 11:41Speaker 2: nice S shaped deflection curve, very efficient.
- 11:44Speaker 1: And hat and built trusses.
- 11:46Speaker 2: Those are fantastic for taller buildings. Their trusses at the
- 11:50Speaker 2: top or middle that connect everything together. They really cut
- 11:53Speaker 2: down on uplift forces and overall deflection.
- 11:55Speaker 1: What about the tubular concept where the whole building facade
- 11:59Speaker 1: acts as a tube.
- 12:00Speaker 2: Superfficient for very tall buildings, but for buildings under say
- 12:04Speaker 2: twenty five or thirty stories, it's usually not economical. You
- 12:07Speaker 2: get this effect called sheer lag because of all the
- 12:10Speaker 2: window openings, and it just compromises the efficiency too much.
- 12:14Speaker 1: So when we put this all together for the young
- 12:16Speaker 1: professional listening, it seems like the gap between just an
- 12:20Speaker 1: adequate design and a truly high performance one comes down
- 12:23Speaker 1: to just a few key decisions.
- 12:25Speaker 2: That's right. It's about minimizing the piece count, it's about
- 12:28Speaker 2: using the right steel, it's about boosting live load for value,
- 12:31Speaker 2: and it's about getting your lateral geometry right.
- 12:34Speaker 1: These aren't just minor technical details, No.
- 12:37Speaker 2: They're the financial and performance drivers of the whole project.
- 12:41Speaker 2: If you internalize these ideas, your designs won't just be sound,
- 12:44Speaker 2: they'll be superior.
- 12:46Speaker 1: And that brings us to your final application exercise. Imagine
- 12:50Speaker 1: you are designing a twelve story steel building. Wind drift
- 12:54Speaker 1: is controlling your lateral design. In your model, You've got
- 12:57Speaker 1: k Braising Bentz, but the apex of the braces points down.
- 13:00Speaker 1: Based on everything we've just discussed, why would you, as
- 13:03Speaker 1: the design engineer, immediately go check your drawings to make
- 13:06Speaker 1: sure that apex points up.
- 13:08Speaker 2: Think about that thirty five percent difference. The answer is
- 13:11Speaker 2: all about how that choice impacts story rotation and column stream.
- 13:14Speaker 1: If these details grabs your attention, we really encourage you
- 13:18Speaker 1: to go explore the Aisse Design Guide series. Design Guide
- 13:21Speaker 1: OH five was the backbone for today's deep dive. Until
- 13:24Speaker 1: next time, keep digging into the details.