Latest / Pharmacy Made Simple / Atlas of Polysomnography
Transcript
- 0:00Speaker 1: Welcome back to the deep dive. If you're involved in pharmacology,
- 0:03Speaker 1: maybe creating educational content, or frankly, any clinical health role,
- 0:07Speaker 1: you know, good treatment relies on solid diagnostics. Today we're
- 0:11Speaker 1: getting into the real nuts and bolts of sleep medicine,
- 0:14Speaker 1: polysymnography or PSG. Our goal here is to give you
- 0:18Speaker 1: really precise summary drawing straight from a key source, the
- 0:21Speaker 1: Atlas of Polysymnography, second edition. We're focusing on those technical
- 0:25Speaker 1: standards that ensure you get accurate results.
- 0:27Speaker 2: Absolutely, if you're interpreting a sleep study, maybe deciding on medication,
- 0:31Speaker 2: understanding titration effects, you have to know these technical rules.
- 0:35Speaker 2: I mean, if the signals aren't captured right or events
- 0:38Speaker 2: are scored wrong, well your whole management plan could be
- 0:42Speaker 2: based on faulty data.
- 0:43Speaker 1: So this knowledge is fundamental for rational.
- 0:45Speaker 2: Treatment exactly, it's the prerequisite.
- 0:47Speaker 1: Okay, let's unpack this. We've moved a long way from
- 0:49Speaker 1: those nineteen seventies analog paper charts to today's digital systems.
- 0:55Speaker 1: What's the biggest technical game changer with digital?
- 0:58Speaker 2: Oh? Easily the sampling, right, it's fun I'm mental. That's
- 1:00Speaker 2: how often we convert the continuous analog body signal into
- 1:04Speaker 2: digital points. If that rate's too low for the signal,
- 1:07Speaker 2: you literally lose information, You distort the picture.
- 1:10Speaker 1: How low is too low? Does it vary?
- 1:12Speaker 2: It does. For signals that change quickly, like brain waves
- 1:15Speaker 2: EEG or muscle activity EMG, you need high rates. We're
- 1:19Speaker 2: talking two hundred and fifty hertz, maybe even higher. And
- 1:22Speaker 2: here's why it matters so much. Imagine the eye movement channel.
- 1:26Speaker 2: If your sampling rate is too slow, a quick, sharp,
- 1:29Speaker 2: rapid eye movement REM, which defines rem sleep, well, it
- 1:33Speaker 2: might get smoothed out, distorted and look like a slow
- 1:35Speaker 2: eye movement or SEM, which defines stage N one sweep precisely.
- 1:39Speaker 2: So a simple technical setting error leads to misstaging the
- 1:42Speaker 2: patient's sleep. It's that critical.
- 1:43Speaker 1: Wow. So faster signals need faster sampling. What about slower
- 1:46Speaker 1: ones like breathing.
- 1:47Speaker 2: Yeah, for things like chess movement breathing effort, you only
- 1:50Speaker 2: need maybe twenty hurts much slower. But the beauty of
- 1:53Speaker 2: digital is the flexibility too. You can zoom out use
- 1:57Speaker 2: a compressed tin scale to spot things like periodic leg
- 2:00Speaker 2: movements happening over say twenty or thirty seconds, or you
- 2:05Speaker 2: can instantly zoom in expand the timescale to examine really
- 2:09Speaker 2: brief events like tiny EEG spikes, maybe apleictiform activity or
- 2:13Speaker 2: a K complex.
- 2:14Speaker 1: Right, that makes sense. Before we leave the sort of
- 2:17Speaker 1: hardware side, let's quickly touch on amplifiers. Differential amplifiers are key.
- 2:21Speaker 1: They look at the difference between two points.
- 2:22Speaker 2: They also need to ignore background.
- 2:24Speaker 1: Noise, right exactly how do they do that?
- 2:25Speaker 2: That's where the common mode rejection ratio where CMRR comes in.
- 2:29Speaker 2: It's a measure of how well the amplifier rejects noise
- 2:32Speaker 2: that's present on both input lines, like the sixty hertz
- 2:35Speaker 2: hum from electrical wiring. A good CMRR ensures we're amplifying
- 2:39Speaker 2: the patient's physiology, not the room's electrical noise.
- 2:41Speaker 1: And we need standard polarity too. Input one negative relative
- 2:45Speaker 1: to input two means the pen goes up or the
- 2:47Speaker 1: signal to flex upward on screen. Seems small, but consistency
- 2:51Speaker 1: is vital.
- 2:52Speaker 2: For scoring, absolutely vital.
- 2:53Speaker 1: Now, filters they clean up the signal. But there's a
- 2:56Speaker 1: catch with the low frequency filter.
- 2:58Speaker 2: The LFS yes, a big one. Filters are essential for
- 3:01Speaker 2: removing unwanted noise. The LFF cuts out slow frequencies. The
- 3:06Speaker 2: HFF cuts out fast ones, but the LFF introduces a
- 3:09Speaker 2: significant phase shift. It makes the waveform appear slightly earlier
- 3:13Speaker 2: in time than it actually occurred.
- 3:15Speaker 1: Okay, why is that a problem practically? Why should someone
- 3:18Speaker 1: thinking about, say, medication, care about a phase shift?
- 3:21Speaker 2: Because if you're trying to pinpoint the exact timing relationship
- 3:24Speaker 2: between a brain event like an epileptic discharge and maybe
- 3:27Speaker 2: a muscle twitch, that phase shift can mess things up.
- 3:31Speaker 2: It might make the EEG event look like it precedes
- 3:34Speaker 2: the muscle event when maybe it doesn't, or the timing
- 3:36Speaker 2: is different. It clouds the interpretation of brief events.
- 3:39Speaker 1: I see. So technical detail impacts diagnostic interpretation directly. Okay,
- 3:43Speaker 1: Just to round this off, a standard PSG pulls together EEG,
- 3:47Speaker 1: EOG for eyes, EMG for muscle airflow, breathing effort, oxygen
- 3:51Speaker 1: saturation SA you two EKG for heart.
- 3:53Speaker 2: And limb movements, snoring. Yeah, that's a whole system. Stapshot.
- 3:56Speaker 1: All right, we've got the signals recorded accurately. Now we
- 3:59Speaker 1: need the rule book to interpret the language of sleep science. Yeah,
- 4:03Speaker 1: let's talk about defining the sleep period itself, the architecture.
- 4:06Speaker 1: What are those key metrics?
- 4:07Speaker 2: Okay, First, the basic time blocks. Total monitoring time TBT
- 4:12Speaker 2: is simple lights out to lights on, easy enough. Total
- 4:15Speaker 2: sleep time TST is just the sum of all the
- 4:18Speaker 2: time spent actually a sleep, so stages N one, N two,
- 4:22Speaker 2: and three R plus any movement time ETPOX and.
- 4:26Speaker 1: Sleep period time SPT. That's slightly different.
- 4:29Speaker 2: Yeah, SPT starts from when the patient first falls asleep
- 4:32Speaker 2: until their final awakening, so it includes TST plus anytime
- 4:35Speaker 2: you woke up during the night after initially falling asleep.
- 4:37Speaker 1: Which is way so awake after sleep on set makes.
- 4:40Speaker 2: Sense exactly, And from those we get a key quality measure,
- 4:43Speaker 2: sleep efficiency.
- 4:44Speaker 1: How's that calculated?
- 4:45Speaker 2: Simple ratio TST divided by TBT then multiplied by one
- 4:49Speaker 2: hundred to get a percentage hire is generally better.
- 4:51Speaker 1: Got it? And then there are the latencies, right.
- 4:54Speaker 2: Two main ones. Sleep latency is how long it takes
- 4:57Speaker 2: from lights out until the very first epoch of any
- 5:00Speaker 2: sleep stage. And REM latency is the time from that
- 5:04Speaker 2: first sleep epoch until the first epoch of REM sleep
- 5:08Speaker 2: and that REM latency it can be really informative clinically.
- 5:11Speaker 1: We'll come back to that. Okay, let's get into the
- 5:13Speaker 1: EEG definitions for the actual sleep stages epoch by epoch,
- 5:17Speaker 1: starting with just being awake.
- 5:19Speaker 2: Right, If the patient is awake with their eyes closed,
- 5:22Speaker 2: you'll see prominent alpha activity. That's the eight to thirteen
- 5:25Speaker 2: hertz rhythm, and it needs to be there for more
- 5:27Speaker 2: than half the thirty second epoch.
- 5:29Speaker 1: Okay, Then they drift off into stage N one light sleep.
- 5:33Speaker 2: Now the ELF activity drops off. It occupies less than
- 5:35Speaker 2: fifty percent of the epoch. You get a lower voltage,
- 5:37Speaker 2: mixed frequency pattern, and often you'll see those slowy movements
- 5:40Speaker 2: the sums we mentioned earlier.
- 5:41Speaker 1: And then comes stage in two, which is where most
- 5:44Speaker 1: people spend a lot of their sleep time. What defines
- 5:46Speaker 1: end two N.
- 5:47Speaker 2: Two needs very specific markers. You need to see at
- 5:50Speaker 2: least one K complex that's a big, sharp looking biphasic
- 5:53Speaker 2: wave lasting more than half a second. Or you need
- 5:56Speaker 2: to see a sleep spindle that's a burst of faster
- 5:58Speaker 2: waves twelve to fourteen hurts lasting between half a second
- 6:01Speaker 2: and one point five seconds.
- 6:03Speaker 1: So either a K complex or a spindle marks the
- 6:05Speaker 1: arrival of end two.
- 6:06Speaker 2: Yes, but there's a crucial condition. The epoch must have
- 6:09Speaker 2: less than twenty percent slow wave activity. If it has
- 6:12Speaker 2: more than that, it tips into end three.
- 6:14Speaker 1: Okay, so that leads us to stage N three deep
- 6:17Speaker 1: sleep or slow wave sleep. It's all that those slow
- 6:20Speaker 1: waves exactly.
- 6:21Speaker 2: The rule is simple. More than twenty percent of the
- 6:23Speaker 2: epoch must consist of slow wave activity, and that activity
- 6:26Speaker 2: itself has strict criteria. The waves have to be slow
- 6:29Speaker 2: frequency less than two hertz, and they have to be
- 6:31Speaker 2: high amplitude over seventy five microvolts peak to peak. That's
- 6:34Speaker 2: the definition of restorative deep sleep.
- 6:36Speaker 1: And finally, Stage R or rem sleep.
- 6:38Speaker 2: Remsleep looks different again. The EG is low voltage, mixed frequency,
- 6:42Speaker 2: a bit like N one or wakefulness. Actually, but you
- 6:45Speaker 2: see definite, jerky rapid eye movements remms and the absolute
- 6:49Speaker 2: key physiological sign is a drop in chin muscle tone.
- 6:52Speaker 2: The EMG signal becomes relatively flat. That's muscle atonia.
- 6:55Speaker 1: Any other characteristic wave forms in rem.
- 6:57Speaker 2: You might see saw tooth waves. They're sort of notched
- 7:00Speaker 2: waves in the theater range around three to seven hrtz,
- 7:03Speaker 2: often preceding the rum bursts themselves.
- 7:06Speaker 1: Now, the alice points out clinical factors affect this staging
- 7:09Speaker 1: right like sleep.
- 7:10Speaker 2: Apnea, Oh, definitely, severe obstructive sleep apnea can just obliterate
- 7:14Speaker 2: in three sleep patients might get none, and it often
- 7:18Speaker 2: reduces REM sleep too.
- 7:19Speaker 1: And that REM latency you mentioned earlier.
- 7:21Speaker 2: Yeah, if someone enters remsleep really quickly, say less than
- 7:24Speaker 2: seventy minutes after falling asleep, that can be a flag
- 7:26Speaker 2: for things like depression or even narcolepsy. It's a significant finding.
- 7:30Speaker 1: And scoring kids is totally different.
- 7:32Speaker 2: Completely different rule book, especially for newborns. They don't have
- 7:35Speaker 2: the same mature EEG patterns. You score active sleep, which
- 7:39Speaker 2: is like REM, quiet sleep, like n REM and indeterminate sleep,
- 7:44Speaker 2: and their sleep cycles are much shorter, maybe forty five
- 7:47Speaker 2: to sixty minutes, not the ninety one hundred minutes we
- 7:49Speaker 2: see in adults.
- 7:50Speaker 1: Let's shift gears to respiratory events. This is obviously core
- 7:53Speaker 1: for diagnosing sleep apnea. Yeah, and the h I score
- 7:56Speaker 1: drives treatment, So the monitoring tech matters hugely. How do
- 8:00Speaker 1: we measure air flow?
- 8:01Speaker 2: Well, there are basically two main approaches. The older method
- 8:04Speaker 2: uses thermisters or thermocouples. They detect temperature changes between inhaled
- 8:09Speaker 2: and exhaled air. The problem is they're really only good
- 8:13Speaker 2: at detecting the complete absence of flow and apnea they're
- 8:16Speaker 2: slow to respond and pretty poor at picking up partial
- 8:19Speaker 2: reductions or hypopnias.
- 8:20Speaker 1: So what's better for hypopyas.
- 8:22Speaker 2: The nasal pressure transducer. This is much more sensitive. It
- 8:25Speaker 2: measures pressure changes in the nasal canula and the signal
- 8:28Speaker 2: is proportional to flow squared. This makes it great for
- 8:31Speaker 2: spotting that telltale sign of upper airway resistance flow limitation
- 8:36Speaker 2: where the top of the inspiratory waveform gets flattened or
- 8:38Speaker 2: squared off. You need this to score hypopnia's accurately by
- 8:42Speaker 2: current standards.
- 8:43Speaker 1: Right, And what about measuring breathing effort? Is the patient
- 8:46Speaker 1: trying to breathe?
- 8:47Speaker 2: We typically use respiratory inductance plethysmography or RIP belts around
- 8:52Speaker 2: the chest and abdomen. They're much better than older PSO belts.
- 8:55Speaker 2: Why better because you can sum the signals from the
- 8:57Speaker 2: chest and abdomen called r ipsum and get a decent
- 9:00Speaker 2: that's an estimate of changes in tidal volume how much
- 9:02Speaker 2: air is moving?
- 9:03Speaker 1: Is there even more sensitive way?
- 9:05Speaker 2: Oh?
- 9:05Speaker 1: Yes?
- 9:06Speaker 2: The gold standard, especially for subtle effort changes or complex cases,
- 9:10Speaker 2: is esophageal pressure monitoring. A casseter in the esophagus directly
- 9:14Speaker 2: measures intrathoracic pressure swings very sensitive but more invasive.
- 9:19Speaker 1: Okay, And the outcome we track is oxygen saturation APO
- 9:22Speaker 1: two using pulsax symmetry for clinicians setting treatment thresholds. What
- 9:27Speaker 1: defines a significant desaturation and is there a timing trick?
- 9:30Speaker 2: A significant drop is generally defined as four percent or
- 9:33Speaker 2: more from the person's baseline oxygen level. And yes, the
- 9:37Speaker 2: timing is crucial. There's a circulatory delay. The lowest point
- 9:40Speaker 2: of the oxygen saturation, the NATAR, typically happens about six
- 9:43Speaker 2: to eight seconds after the actual breathing event the apnea
- 9:46Speaker 2: or hypopnia has ended.
- 9:47Speaker 1: Ah. So you can't just score the desaturation the moment
- 9:50Speaker 1: breathing restarts. You have to wait to see the full
- 9:52Speaker 1: effect exactly.
- 9:53Speaker 2: Automated systems might miss that nuance. Sometimes human scoring needs
- 9:57Speaker 2: to account for that delay.
- 9:58Speaker 1: Okay. Let's nail down the effec AASM scoring rules for adults.
- 10:02Speaker 2: First, Apnea and appne is pretty straightforward. Airflow basically stops
- 10:06Speaker 2: or drops to less than ten percent of baseline for
- 10:09Speaker 2: ten seconds or longer. Then we classify it based on effort.
- 10:12Speaker 2: Obstructive if effort continues, central, if effort stocks too and
- 10:17Speaker 2: mixed if it starts central and then obstructive effort appears.
- 10:20Speaker 1: Got it now, hypopnia, These rules seem a bit more complex.
- 10:25Speaker 1: There are two ways to score one.
- 10:26Speaker 2: That's right. Hypopnia also has to last ten seconds or more.
- 10:30Speaker 2: Then it has to meet one of two conditions. Condition
- 10:33Speaker 2: one involves a significant physiological change at least a thirty
- 10:36Speaker 2: percent drop in the nasal pressure signal plus at least
- 10:39Speaker 2: a four percent oxygen desaturation.
- 10:41Speaker 1: Okay, thirty percent drop plus four percent p sattle? What's
- 10:44Speaker 1: the second pathway?
- 10:45Speaker 2: The second pathway allows for a slightly less severe desaturation
- 10:48Speaker 2: if the airflow drop is bigger, or if it causes
- 10:50Speaker 2: an arousal. So it's at least a fifty percent drop
- 10:53Speaker 2: in nasal pressure plus either a three percent desaturation or
- 10:56Speaker 2: an EEG arousal associated with the event I see.
- 10:59Speaker 1: So it's either a my drop with a big d
- 11:01Speaker 1: ST or a big drop with a smaller d set
- 11:03Speaker 1: or an arousal.
- 11:03Speaker 2: You've got it. Those specific threshold or why accurate measurement
- 11:06Speaker 2: is so critical?
- 11:07Speaker 1: And if something looks like a respiratory disturbance causes an
- 11:10Speaker 1: arousal but doesn't quite meet the apnea or hypopnia definitions.
- 11:15Speaker 2: That's where the RIrA comes in. Respiratory effort related arousal.
- 11:19Speaker 2: It's an event again ten seconds or longer that leads
- 11:22Speaker 2: to an arousal from sleep. You see evidence of increasing
- 11:25Speaker 2: breathing effort like that flattened nasal pressure wave form or
- 11:28Speaker 2: changes on pests if you have it, but the event
- 11:31Speaker 2: doesn't meet the strict flow reduction or desaturation criteria for
- 11:35Speaker 2: an apnea or hypopnia, it's still fragments sleep.
- 11:37Speaker 1: Okay, And how do we put it all together for severity?
- 11:40Speaker 2: Severity is primarily based on the AHI the apnea hypopnia index.
- 11:44Speaker 2: That's the total number of apneas and hypopnias divided by
- 11:47Speaker 2: the hours of sleep. The cutoffs are Normal is less
- 11:50Speaker 2: than five events per hour, Mild is five up to fifteen,
- 11:53Speaker 2: Moderate is fifteen up to thirty, and severe is thirty
- 11:56Speaker 2: or more per hour.
- 11:57Speaker 1: And sometimes we see rdy I mentioned.
- 11:59Speaker 2: Right, or respiratory disturbance index is simply the ACHI plus
- 12:03Speaker 2: the ARIRA index or RAIS per hour. So RDI equals
- 12:07Speaker 2: AHI plus rear rashre It captures a slightly broader picture
- 12:10Speaker 2: of respiratory sleep disruption.
- 12:11Speaker 1: Okay, So that covers the breathing side. What about other
- 12:15Speaker 1: key data? Let's quickly summarize leg movements often seen with
- 12:18Speaker 1: sleep apnea.
- 12:19Speaker 2: Right, very often. Yes, We monitor leg movements using EMG
- 12:23Speaker 2: electrodes on the anterior tibual muscle the shin muscle on
- 12:27Speaker 2: both legs. Now, scoring a periodic limb movement, PLM is
- 12:31Speaker 2: incredibly specific about timing. The movement itself has to last
- 12:35Speaker 2: between zero point five and ten seconds. Crucially, they have
- 12:39Speaker 2: to occur in a series at least four movements in
- 12:42Speaker 2: a row, and the time between the start of one
- 12:44Speaker 2: movement and the start of the next must be more
- 12:47Speaker 2: than five seconds but less than ninety seconds.
- 12:49Speaker 1: Wow, very precise, windows extremely and one more rule.
- 12:52Speaker 2: The sequence has to start during sleep, preceded by at
- 12:55Speaker 2: least ten seconds of stable sleep.
- 12:57Speaker 1: So you don't count fidgeting wall awake. How is it reported?
- 13:00Speaker 2: We calculate the PLM index, which is the number of
- 13:02Speaker 2: plms per hour of total sleep time. If the movements
- 13:05Speaker 2: frequently cause arousals, we look at the PLM arousal index,
- 13:08Speaker 2: and arousal index over twenty five per hour is considered severe.
- 13:11Speaker 1: Any link to Wrestle's leg syndrome.
- 13:13Speaker 2: Yes, clinically, if similar leg movements are observed while the
- 13:16Speaker 2: patient is awake PMW, that's a strong suggestion of ROLS.
- 13:21Speaker 2: But RLS itself remains a clinical diagnosis based on symptoms,
- 13:25Speaker 2: not just the PSG finding.
- 13:26Speaker 1: Gotcha. The atlas also flags some serious EKG abnormalities that
- 13:30Speaker 1: can happen during sleep, often linked to apneas.
- 13:33Speaker 2: Absolutely severe apneas put huge stress on the heart. The
- 13:37Speaker 2: book shows examples of profound sinus brady cardia, very slow
- 13:41Speaker 2: heart rate and even assistly where the heart stops completely
- 13:44Speaker 2: for brief periods. They cite cases of three second pauses
- 13:48Speaker 2: right as an apnea ends.
- 13:49Speaker 1: That's frightening, it is.
- 13:51Speaker 2: Other things seen include dangerous ventricular rhythms like pagemony tradegemony
- 13:55Speaker 2: where there are abnormal beats every second or third beat,
- 13:58Speaker 2: and even runs of wide complex tachic cardia, a very fast,
- 14:01Speaker 2: unstable heart rhythm often triggered by the arousal following an event.
- 14:04Speaker 1: Okay, finally, let's touch on technical gremlins artifacts What common
- 14:08Speaker 1: things interfere with the recording?
- 14:09Speaker 2: Well, Aside from the standard sixty hertz electrical noise, two
- 14:13Speaker 2: are very common. Cardio ballistic artifact is where the heartbeat
- 14:16Speaker 2: actually shakes the body enough to show up on the
- 14:18Speaker 2: respiratory effort belts or even the PEZ channel. It can
- 14:21Speaker 2: mimic breathing effort and sweat artifact is also frequent. It
- 14:25Speaker 2: causes slow rolling waves, often looking like delta waves, usually
- 14:29Speaker 2: worst over the back of the head. It can obscure
- 14:32Speaker 2: the real EEG right.
- 14:34Speaker 1: Need to watch out for those. And on a practical
- 14:36Speaker 1: note for clinicians managing patients after diagnosis, the ATLAS offered
- 14:40Speaker 1: some SEAPAP troubleshooting tips.
- 14:41Speaker 2: Yes, some common sense fixes for nasal congestion or drainage.
- 14:45Speaker 2: Simple things like nasal saline or steroid sprays can help
- 14:48Speaker 2: a lot. If a patient struggles exhaling against the seapet pressure,
- 14:52Speaker 2: adjusting the machine settings to use pressure relief on exhalation
- 14:55Speaker 2: like seaflex or EPR, or switching to a bi level
- 14:57Speaker 2: machine often solves it.
- 14:58Speaker 1: What about feeling cluster phobic with the mask?
- 15:01Speaker 2: That needs a multi promped approach, usually good education, trying
- 15:04Speaker 2: different mask styles for comfort, maybe desensitization practice, and sometimes
- 15:08Speaker 2: as a last resort for initiation, a short course of
- 15:11Speaker 2: a mild sedative might be considered.
- 15:13Speaker 1: Underguidance, it really highlights how understanding the technical basis flows
- 15:17Speaker 1: right into practical patient management.
- 15:19Speaker 2: Exactly right. This complexity isn't just for show. It's what
- 15:22Speaker 2: ensures diagnostic accuracy. We're integrating brain, muscle, breathing, heart function.
- 15:28Speaker 2: Understanding these standards is the bedrock for effective treatment, whether
- 15:32Speaker 2: it's medication, devices or other therapies. Hashtags tagh, tag outro okay.
- 15:37Speaker 1: To wrap things up and help cement this, let's try
- 15:39Speaker 1: a quick review question. Focus on those strict rules for
- 15:43Speaker 1: deep sleep we discussed. Think about defining stage end three sleep.
- 15:47Speaker 1: What are the three specific numerical criteria the frequency limit,
- 15:52Speaker 1: the AMP and tude threshold, and the percentage of the
- 15:54Speaker 1: APEC that must be meant for an epoch to be
- 15:56Speaker 1: definitively scored as M three.
- 15:59Speaker 2: Pause for listener to think.
- 16:00Speaker 1: All right, I'm all that over. We really appreciate you
- 16:02Speaker 1: diving deep with us into the technical world of the
- 16:04Speaker 1: sleep atlas. Having this precise knowledge really empowers you to
- 16:08Speaker 1: make sound, evidence based decisions for your patients or your learning.
- 16:11Speaker 1: Absolutely thanks for listening, and we'll catch you on the
- 16:13Speaker 1: next deep dive.