Latest / Civil Engineering Made Simple / Economic Concrete Frame Elements
Transcript
- 0:00Speaker 1: Welcome back to the deep dive. Today, we are moving
- 0:03Speaker 1: from the conceptual to the structural. We're going deep into
- 0:06Speaker 1: the foundations of multi story buildings, specifically the reinforced concrete frame.
- 0:12Speaker 2: Yeah, and we're focusing on a really remarkable resource for
- 0:15Speaker 2: engineers and students. It's a pre scheme design handbook called
- 0:19Speaker 2: Economic Concrete Frame Elements. And this isn't a textbook, it's
- 0:23Speaker 2: more of a shortcut. It distills complex code into these
- 0:27Speaker 2: quick sizing charts.
- 0:28Speaker 1: So our mission for you, the learner, is to really
- 0:31Speaker 1: unpack the thinking behind that conceptual design phase. How do
- 0:34Speaker 1: you write at the start of a project, quickly figure
- 0:37Speaker 1: out the least cost concrete options before you even get
- 0:40Speaker 1: into the detailed design.
- 0:41Speaker 2: And that focus on cost is just it's everything. Especially
- 0:45Speaker 2: when we talk about floor plates. We're working with data
- 0:47Speaker 2: based on the principles of BS eighty one ten and
- 0:50Speaker 2: this research tells us the floor system that horizontal plate
- 0:54Speaker 2: accounts for a staggering eighty five percent of the superstructure.
- 0:57Speaker 1: Costs eighty five percent.
- 0:58Speaker 2: Wow, that's where you make or lose all your money.
- 1:00Speaker 1: That figure just changes the whole focus of preliminary design,
- 1:03Speaker 1: doesn't it. Okay, Before we jump into the charts, we
- 1:07Speaker 1: need to set a couple of crucial boundaries for you. First,
- 1:10Speaker 1: this is a pre scheme tool. It's for budgeting, for feasibility.
- 1:15Speaker 1: It absolutely cannot be used for the final structural design.
- 1:19Speaker 2: And second, equally critical for any engineer listening, this entire
- 1:24Speaker 2: framework explicitly does not cover lateral stability.
- 1:28Speaker 1: So things like wind or seismic loads completely separate.
- 1:31Speaker 2: That resistance has to be provided independently. Usually you'd use
- 1:34Speaker 2: sheer walls or a concrete core, and that's a whole
- 1:37Speaker 2: other analysis. This is purely about supporting vertical load gravity basically.
- 1:42Speaker 1: Okay, let's start at the beginning. Then you've been handed
- 1:44Speaker 1: to concept drawing. How do you even begin to size
- 1:46Speaker 1: these elements? I guess that's section one the pre scheme
- 1:49Speaker 1: design process, right.
- 1:50Speaker 2: The very first step is just defining the basic criteria.
- 1:52Speaker 2: You need, the layout, the spans, what the space is
- 1:54Speaker 2: going to be used for, and from that the loads.
- 1:57Speaker 1: Okay, so are we talking about a general office be
- 2:00Speaker 1: two point five kiling Newton's per square.
- 2:02Speaker 2: Meter or is it a high spec office or maybe
- 2:05Speaker 2: a storage area that pushes you up cords five? You
- 2:08Speaker 2: have to know that first and.
- 2:09Speaker 1: That load combined with the longest span on the grid.
- 2:13Speaker 1: That gives you the starting point for the whole thing.
- 2:15Speaker 2: It does you find the worst case scenario for both
- 2:17Speaker 2: span and load, and then you start following the load
- 2:20Speaker 2: path down element by element, And the handbook makes this
- 2:23Speaker 2: initial sizing process well, really quite elegant. How so, for slabs,
- 2:29Speaker 2: the most economic depths are just plotted right against the span.
- 2:31Speaker 2: For a given load, you look up your span and load,
- 2:34Speaker 2: and boom, the chart suggests the most anconomical thickness. Simple enough.
- 2:38Speaker 1: What about beams?
- 2:39Speaker 2: For beams, the size is driven by what we call
- 2:41Speaker 2: the auto the ultimate applied uniformly distributed load and whatever
- 2:46Speaker 2: web with you choose, okay?
- 2:47Speaker 1: And then finally the columns holding everything up.
- 2:50Speaker 2: And for columns, their size is based on the total
- 2:52Speaker 2: ultimate axio load they're carrying way down at the lowest level.
- 2:55Speaker 2: A good approximation is just to multiply the ultimate load
- 2:58Speaker 2: from one floor bay by the number of stories above it.
- 3:01Speaker 1: That systematic flow makes a lot of sense, but the
- 3:04Speaker 1: data is built on this principle that minimum material content
- 3:09Speaker 1: is not always the best value. That sort of runs
- 3:13Speaker 1: contrary to basic instincts, doesn't it? Why is that so important?
- 3:16Speaker 2: It's the cost of complexity in time. I mean, sure,
- 3:19Speaker 2: minimum concrete saves on material, but it might require really
- 3:22Speaker 2: complex form work or a much deeper slab, which then
- 3:27Speaker 2: increases the building's overall height, and that hits your cladding costs.
- 3:31Speaker 2: I see. So engineers have to use their judgment. You know,
- 3:34Speaker 2: they have to compare options based on the total floor
- 3:36Speaker 2: plate cost.
- 3:37Speaker 1: So you're not just looking at concrete and steel rates.
- 3:40Speaker 1: You're factoring in the concrete, the reinforcement, the form work,
- 3:42Speaker 1: which is all about labor and time, and then these
- 3:45Speaker 1: indirect costs like cladding changes and even the cost to
- 3:48Speaker 1: support the element's own weight.
- 3:50Speaker 2: Exactly. A slightly thicker slab might use more concrete, but
- 3:53Speaker 2: if it lets you use simpler formwork and speeds up
- 3:56Speaker 2: the construction schedule, or if that thickness makes it easier
- 3:58Speaker 2: to run services through, it will almost certainly be the
- 4:01Speaker 2: best value choice. Time is money. Formwork complexity just burns time.
- 4:06Speaker 1: Let's move on then, and look at where most of
- 4:08Speaker 1: that eighty five percent cost actually lives. The four systems
- 4:12Speaker 1: they're grouped into what in situ, pre cast and post tensioned.
- 4:16Speaker 2: That's right for institution so concrete poured on site. We
- 4:20Speaker 2: generally see four main types, and each one kind of
- 4:23Speaker 2: dominates a specific span range. The flat slab is well,
- 4:28Speaker 2: it's the darling of conceptual design because of that plane
- 4:31Speaker 2: flat soft.
- 4:32Speaker 1: Right, which is fantastic for mechanical and electrical services. No
- 4:35Speaker 1: beams to punch through or route around.
- 4:37Speaker 2: Precisely, it's simple, quick to construct and often the most
- 4:40Speaker 2: economic choice. Ver say, spans up to about seven and
- 4:43Speaker 2: a half meters, But that lack of depth creates two
- 4:46Speaker 2: big design headaches. You have to think really carefully about
- 4:49Speaker 2: deflection and its susceptibility to punching sheer right around the.
- 4:53Speaker 1: Columns, and dealing with punching sheer can get complicated, right.
- 4:55Speaker 2: Oh yeah, you often need thickened column heads or are
- 4:58Speaker 2: some very complex reinforcement layouts.
- 5:00Speaker 1: So what happens when you go beyond that's seven and
- 5:02Speaker 1: a half meter span.
- 5:03Speaker 2: Well, you start looking at systems with more depth, more stiffness.
- 5:07Speaker 2: One way, slabs, either solid or ribbed, are pretty economic
- 5:11Speaker 2: over a wider range, but they need downstand beams to
- 5:14Speaker 2: support them.
- 5:14Speaker 1: And those beams get in the way of services and
- 5:17Speaker 1: you might have to increase your whole story height to
- 5:19Speaker 1: get the clearance you need.
- 5:20Speaker 2: That is the core trade off. You're trading construction speed
- 5:24Speaker 2: for better structural efficiency at longer spans. In Citi rib
- 5:28Speaker 2: slabs can push that span out to say twelve meters.
- 5:31Speaker 2: They're also lightweight, which saves on column and foundation costs,
- 5:35Speaker 2: but your form work is suddenly way more complex and
- 5:37Speaker 2: expensive than a simple flat slab.
- 5:39Speaker 1: And then for even longer spans.
- 5:40Speaker 2: For medium to long spans up to maybe fourteen point
- 5:43Speaker 2: four meters, you have the waffle slab. It's very lightweight,
- 5:46Speaker 2: structurally efficient in two directions, but again construction can be slower,
- 5:51Speaker 2: and that waffle pattern form work is inherently very costly.
- 5:54Speaker 1: Okay, So it seems like as spans increase with institute concrete,
- 5:57Speaker 1: the complexity and the form work costs just shoot up.
- 6:00Speaker 1: What if your top priorities are speed and minimizing depth,
- 6:03Speaker 1: then you move away.
- 6:04Speaker 2: From siteboard concrete. Precast systems like hollow core units are
- 6:09Speaker 2: a great option. They're widely available, economic, and offer tremendous
- 6:13Speaker 2: speed because you eliminate all that on site formwork and propping.
- 6:16Speaker 1: And these are high grade units I assume.
- 6:18Speaker 2: Very They're typically pre stressed and made using high strength
- 6:21Speaker 2: CE fifty concrete. But if you need the absolute maximum
- 6:24Speaker 2: span with the minimum depth, you turn to post tension
- 6:27Speaker 2: construction PT. Right. This tech actively compresses the concrete. It
- 6:33Speaker 2: lets you span much much further. We see PT beams
- 6:37Speaker 2: spanning up to eighteen meters while keeping the depth down,
- 6:40Speaker 2: controlling deflection and preventing cracking.
- 6:42Speaker 1: That compression is what makes it so efficient, and does
- 6:44Speaker 1: the way you install the tendons. Does that vary between
- 6:47Speaker 1: floors and beams.
- 6:48Speaker 2: It does. Yeah. In floor slabs you generally need less
- 6:51Speaker 2: pre stress, so engineers will typically use what we call
- 6:53Speaker 2: monostrand unbonded tendons. They just sit in a plastic duct.
- 6:57Speaker 2: But in deep beams, where you need a much higher force,
- 7:00Speaker 2: you use multi strand bonded tendons, which are housed in
- 7:03Speaker 2: ducts filled with grout. That ensures a much better force
- 7:06Speaker 2: transfer and fire performance.
- 7:07Speaker 1: That's a really comprehensive look at the eighty five percent driver.
- 7:11Speaker 1: So now that we've sized the horizontal elements, the money savers,
- 7:14Speaker 1: we have to make sure the vertical path can handle
- 7:17Speaker 1: all that load. Let's talk section three the supporting structure,
- 7:21Speaker 1: the beams and columns.
- 7:23Speaker 2: Okay, starting with beams, that support the slabs. The handbook
- 7:26Speaker 2: looks at three main in situ types based on how
- 7:29Speaker 2: the slab interacts with them. You have the simple rectangular beam,
- 7:32Speaker 2: an inverted L beam for the perimeter, and then the
- 7:35Speaker 2: classic T beam for internal spans, where the slab acts
- 7:38Speaker 2: as a flange on both sides.
- 7:40Speaker 1: So the beam's behavior is totally tied to its location
- 7:43Speaker 1: in the floor plate.
- 7:43Speaker 2: It really is. Now here's a practical detail for former efficiency.
- 7:47Speaker 2: Wide flat beams are usually cheaper to build than narrow
- 7:50Speaker 2: deep ones. You really want to try and match your
- 7:53Speaker 2: beamwidth to your column with for a clean, simple transition.
- 7:57Speaker 1: Okay.
- 7:57Speaker 2: We also find that initial sizing often minimizes the section area,
- 8:01Speaker 2: but that can lead to high deflections.
- 8:03Speaker 1: Ah, so we're always fighting serviceability. What does the handbook
- 8:07Speaker 1: say to do when deflection is the problem, not ultimate strength?
- 8:11Speaker 2: It suggests increasing the steel reinforcement. By adding more steel,
- 8:15Speaker 2: you reduce the service stress the FS, which effectively stiffens
- 8:19Speaker 2: the beam that lets sit past the deflection check without
- 8:22Speaker 2: having to make it deeper, which, as we said, triggers
- 8:24Speaker 2: all those costly changes to story heightened cladding.
- 8:27Speaker 1: You're designing for stiffness just as much as for strength.
- 8:30Speaker 1: That's a great insight. Okay, let's move to columns. How
- 8:33Speaker 1: does that vertical load path influence their size? As you
- 8:36Speaker 1: go up a.
- 8:37Speaker 2: Building, column sizing is dominated by two things, the total
- 8:41Speaker 2: ultimate axial load, which we call n and the design moment.
- 8:45Speaker 2: For buildability, the ideal is to keep the same column
- 8:49Speaker 2: size and shape all the way up the building. It
- 8:51Speaker 2: just simplifies everything, right, form work, scheduling, everything. You can
- 8:54Speaker 2: usually do that up to about eight stories. But does
- 8:57Speaker 2: the fascinating nuance depending on where the column is low
- 9:00Speaker 2: rise structures, say up to five stories. The perimeter columns
- 9:03Speaker 2: are actually dominated by moment, not axial load.
- 9:06Speaker 1: Meaning the bending force that dictates their size. So does
- 9:08Speaker 1: using high strength concrete help in that case? Not?
- 9:11Speaker 2: Really, no, not for those perimeter columns. The handbook assumes
- 9:15Speaker 2: a base of Grade C thirty five concrete, and while
- 9:18Speaker 2: going to a higher strength can dramatically shrink your internal
- 9:21Speaker 2: columns where the axial load is massive, it offers very
- 9:24Speaker 2: little benefit to the perimeter columns in a low rise building.
- 9:28Speaker 2: Their size is pretty much fixed by their need to
- 9:30Speaker 2: resist bending.
- 9:31Speaker 1: That is a key distinction. Axial load for internal columns
- 9:34Speaker 1: moment for perimeter columns. Okay, let's full back the curtain.
- 9:37Speaker 1: This is where it gets really interesting for me. The economics,
- 9:40Speaker 1: the calculations. The whole handbook is based on finding the
- 9:43Speaker 1: economic option. How did they actually determine that minimum total cost?
- 9:48Speaker 1: Especially using rates from nineteen ninety six.
- 9:50Speaker 2: The value here is in the process, not the specific
- 9:53Speaker 2: pound value. What they did was they generated designs for
- 9:57Speaker 2: elements slabs at different depths, for example, and then they
- 10:00Speaker 2: systematically applied budget rates to every single component concrete, reinforcement, form, work, cladding, changes, everything, everything,
- 10:08Speaker 2: And they even included a crucial allowance for supporting the
- 10:11Speaker 2: self weight at about seventy five pence per kilin Newton.
- 10:15Speaker 2: This captures that ripple effect we talked about. A heavier
- 10:18Speaker 2: floor means bigger beams, bigger columns, and bigger foundations.
- 10:22Speaker 1: So the methodology was basically finding the depth that gave
- 10:25Speaker 1: the minimum total cost when you combine the cost of
- 10:27Speaker 1: the element itself with the cost of all its consequences
- 10:30Speaker 1: on the rest of the structure.
- 10:31Speaker 2: Precisely, the process showed that, for instance, a two hundred
- 10:34Speaker 2: and eighty milimeter flat slab, while using more concrete than
- 10:38Speaker 2: a two hundred and fifty mili option gave the best
- 10:40Speaker 2: overall value when you factored everything in. That principle of
- 10:43Speaker 2: finding the optimal depth is completely valid. Today you just
- 10:46Speaker 2: use current rates.
- 10:47Speaker 1: Now let's get into the hard numbers that students really
- 10:49Speaker 1: need to master. Load factors. The charts are all based
- 10:52Speaker 1: on ultimate loads. What's the fundamental formula for that ultimate
- 10:56Speaker 1: slab load?
- 10:57Speaker 2: The ultimate slab load or MS is calculated by taking
- 11:00Speaker 2: your characteristic dead loads g carrows and your imposed loads
- 11:04Speaker 2: q carrows and multiplying each by a partial safety factor.
- 11:08Speaker 2: For this code, the factor for dead loads gamft is
- 11:11Speaker 2: one point four and for imposed loads gamma cork it's
- 11:15Speaker 2: one point six.
- 11:16Speaker 1: And the dead load factor is lower because we know
- 11:18Speaker 1: what those loads are with more certainty. Right, the building's
- 11:21Speaker 1: own weight doesn't change much.
- 11:22Speaker 2: That's exactly right. Deadloads are predictable. Imposed loads people furniture
- 11:28Speaker 2: snow they have a much higher uncertainty, so they get
- 11:32Speaker 2: that higher factor of one point six.
- 11:33Speaker 1: Okay, Now for the tricky part, adjusting for superimposed deadload
- 11:38Speaker 1: or SDL. The charts assume a standard SDL of one
- 11:42Speaker 1: point five killing newtons per square meter. What if your
- 11:45Speaker 1: project has heavier partitions or ceilings. How do you adjust
- 11:49Speaker 1: for that?
- 11:50Speaker 2: This is a crucial conversion and you have to get
- 11:52Speaker 2: it right. If your actual superimposed deadload is different from
- 11:55Speaker 2: that one point five allowance, you have to convert the
- 11:58Speaker 2: difference in the dead load into an equivalent imposed load
- 12:01Speaker 2: to use the chart correctly.
- 12:03Speaker 1: Why the conversion is it because the dead load difference
- 12:05Speaker 1: would normally be factored by one point four, but the
- 12:08Speaker 1: chart is set up to handle variables using the one
- 12:10Speaker 1: point six factor.
- 12:11Speaker 2: Exactly, you adjust the characteristic imposed load by adding the
- 12:14Speaker 2: factor difference. The formula is one point four divided by
- 12:18Speaker 2: one point six times the actual SDL minus one point five.
- 12:22Speaker 2: That conversion factor ensures the safety margin is correct even
- 12:26Speaker 2: though you're using a chart that's standardized on a different assumption.
- 12:29Speaker 2: It's essential for accuracy.
- 12:31Speaker 1: So wrapping this all up, what does it all mean?
- 12:34Speaker 1: Conceptual design with concrete frames is clearly about more than
- 12:37Speaker 1: just minimizing volume. It's about minimizing total construction effort and
- 12:41Speaker 1: downstream cost. So why should an engineer really push for
- 12:46Speaker 1: a concrete frame over say steal.
- 12:48Speaker 2: Well, the research in this handbook gives you three really
- 12:51Speaker 2: compelling pillars. First, cost, if you optimize it correctly, there's
- 12:54Speaker 2: potential for frame cost savings of up to twenty four
- 12:57Speaker 2: percent compared to steel. Second is time. Overall construction schedules
- 13:01Speaker 2: can actually be comparable too, or sometimes even faster than
- 13:04Speaker 2: seal frames, especially with things like precast systems. And third
- 13:07Speaker 2: is performance. Concrete has inherent fire resistance without needing extra sprays.
- 13:13Speaker 2: It has superior thermal mass which helps stabilize temperatures, and
- 13:17Speaker 2: with clever design, it can give you up to one
- 13:19Speaker 2: and a half percent more net leedable area in the building.
- 13:22Speaker 1: That makes a powerful case. Okay, before we finish, let's
- 13:25Speaker 1: cement that crucial idea of load adjustment. This is your
- 13:28Speaker 1: review exercise.
- 13:29Speaker 2: All right. Imagine you have a floor slab. The characteristic
- 13:33Speaker 2: imposed load q case is four point zero kila newtonts
- 13:37Speaker 2: per square meter, but your actual superimposed dead load, your
- 13:40Speaker 2: GQSDL is heavy. It's two point five. Remember the charts
- 13:45Speaker 2: assume one point five. Your chask is to calculate the
- 13:48Speaker 2: equivalent characteristic imposed load you must use to correctly enter
- 13:52Speaker 2: those lab charts.
- 13:53Speaker 1: Think about that difference between your two point five SDL
- 13:55Speaker 1: and the standard one point five allowance. You've got that
- 13:58Speaker 1: extra one kilo newton per square meter of dead load.
- 14:01Speaker 1: You need to convert that using the one point four
- 14:03Speaker 1: to over one point six factor into its equivalent imposed
- 14:05Speaker 1: load component, and then add that to your original four
- 14:07Speaker 1: point zero imposed load. It really shows how every single
- 14:10Speaker 1: preliminary decision is linked