Latest / NTC's Temporal 3 / Episode 34 | ire alarm system documentation, Fire alarm certification levels (1-4) and their requirements, and more
Transcript
- 0:05SPEAKER_00: Hey Brian.
- 0:06SPEAKER_00: How's it going?
- 0:08SPEAKER_00: Good.
- 0:08SPEAKER_00: And also my other co-host, Mr.
- 0:10SPEAKER_00: Charles Ulner.
- 0:11SPEAKER_00: Hello, Charles.
- 0:12SPEAKER_00: Howdy.
- 0:13SPEAKER_00: Well, guys, today I'd like to talk about the difference between different levels of NISAT certification.
- 0:20SPEAKER_00: Specifically, what's the difference between NYSET level one, two, three, and four, other than the amount of exams that you've taken and the amount of money you've spent with NYSET and all the code books that you own?
- 0:31SPEAKER_00: But what is the expectation from NISET?
- 0:34SPEAKER_00: How do they categorize level one, two, and three?
- 0:37SPEAKER_00: Chris, why don't you start us off with level one?
- 0:39SPEAKER_00: What's the expectation from level one?
- 0:42SPEAKER_01: Well, expectation with level one that we see from NYSET, in order to get the certification, you got to have six months in the field.
- 0:50SPEAKER_01: So what you look at with level one technicians is people that are new to the field, your helpers, your um people that are just starting out, learning the business, learning the information, you're new.
- 1:04SPEAKER_01: You're new.
- 1:04SPEAKER_01: Your exam is going to be reflective of that when it comes to the types of questions that you're asked.
- 1:09SPEAKER_01: You're going to be asked things that are going to be more along the lines of something that somebody brand new to the field should know.
- 1:15SPEAKER_01: So it's not a very deep dive into the understanding of the work.
- 1:20SPEAKER_01: It is, I don't want to say completely surface level, but it is more of a, hey, you're brand new.
- 1:26SPEAKER_01: These are things that you should know by now.
- 1:28SPEAKER_00: Absolutely.
- 1:29SPEAKER_00: Charles, I can tell you want to say something.
- 1:32SPEAKER_02: Yeah.
- 1:33SPEAKER_02: Uh all that stuff, Chris just said, that is a bunch of uh I don't want to use a bad word, but malarkey.
- 1:43SPEAKER_02: That's what Knightset wants you to believe.
- 1:45SPEAKER_02: I took the Knights at Level One test and I failed it just like so many others because it's not as described by NYSAT.
- 1:54SPEAKER_02: The Knights at Level One test is tougher than you might expect.
- 1:59SPEAKER_02: It's based on the code, which a lot of us don't have a lot of experience with, regardless of how many years experience you have in the industry.
- 2:08SPEAKER_02: Uh there are questions that come from OSHA.
- 2:13SPEAKER_02: And uh, I mean, sure, we all may be out on job sites working.
- 2:18SPEAKER_02: That doesn't mean we know what the OSHA requirements are.
- 2:21SPEAKER_02: So uh these things are all things that trip us up on the NYSAT level one test.
- 2:28SPEAKER_02: NYSAT wants us to believe that, hey, it's an entry-level test, shouldn't be any problem.
- 2:33SPEAKER_02: You got six months experience in the industry, you should be good to go.
- 2:38SPEAKER_02: I beg to differ.
- 2:39SPEAKER_02: That's just from my personal experience.
- 2:42SPEAKER_02: Oh, here you go.
- 2:43SPEAKER_02: Back to you, Brian.
- 2:44SPEAKER_00: So for level two, what's the expectation for level two, Charles, since you're talking about uh experience for level one?
- 2:50SPEAKER_00: What's the experience for uh expectation for level two?
- 2:53SPEAKER_00: What does NYSET expect?
- 2:54SPEAKER_00: What kind of questions will you see on the exam?
- 2:56SPEAKER_02: Here's what NYSET expects a slightly higher level of pain for level two.
- 3:02SPEAKER_02: At level two, we're gonna experience more code, more in-depth code, uh, and additional code requirements from the IBC.
- 3:11SPEAKER_02: So um NISET will tell us, hey, two years experience, you should be good to go.
- 3:19SPEAKER_02: I believe that's correct.
- 3:20SPEAKER_02: Is that right, Chris?
- 3:22SPEAKER_02: Two years?
- 3:23SPEAKER_01: Two years experience with NISAT uh requires for level two.
- 3:28SPEAKER_02: And uh you know, there are each level of NISAT certification increases in difficulty to a degree uh from my personal experience.
- 3:39SPEAKER_02: Uh I do have to say at the higher levels it was easier because I was more accustomed to NYSET's uh devious ways, but uh it's a challenging test.
- 3:52SPEAKER_02: If you're taking level two, be prepared for for some challenges there, and preparation is key.
- 3:58SPEAKER_02: Chris, what's your thought?
- 4:01SPEAKER_01: Level two uh is the level I failed the most.
- 4:03SPEAKER_01: Uh I had to take it three times for level two, and it's it's stuff that Nysat expects you should know after two years out in the field.
- 4:14SPEAKER_01: All right, that's cool, but a lot of people don't transition from one side of the field to the next.
- 4:20SPEAKER_01: I mean, at level two, you're looked at as somebody that is a seasoned technician working on their own, doing your own documentation, and possibly doing the documentation of one other person, that the other person may be someone you're training or whatnot.
- 4:34SPEAKER_01: And something that for me was a big struggle at level two was at that point in my field experience, I didn't get my hands on a lot of documentation.
- 4:46SPEAKER_01: So I was not very well versed with documentation and the terminology that documentation is used with.
- 4:54SPEAKER_01: And uh I had a few questions come up that would just infuriate me.
- 5:01SPEAKER_01: So, from a technician standpoint, as somebody that has never gotten to see too much documentation, I kept having questions asking about these things called riser diagrams.
- 5:13SPEAKER_01: And uh, as somebody that's never seen a riser diagram or been explained what it is, I'd get so mad that they're bringing up sprinkler during the fire alarm exam.
- 5:24SPEAKER_01: Well, it's riser diagrams are not necessarily in the context of fire alarm anything to do with sprinkler.
- 5:31SPEAKER_01: And so there is this additional knowledge that you've got to kind of have going into it.
- 5:38SPEAKER_01: One of those things is gonna be understanding the bit of documentation that you're gonna be asked about and the terminology that is used for that documentation.
- 5:47SPEAKER_01: So those are some of the things that I encountered that were very frustrating.
- 5:52SPEAKER_02: Well, and I would say on that line, Chris, you're exactly right.
- 5:58SPEAKER_02: The code covers this much material in our experience in the field, we may only be this narrowly focused.
- 6:07SPEAKER_00: Yep.
- 6:08SPEAKER_02: So there's a whole bunch of stuff in the codes that we never experience in the field because our focus in the field work is very narrow.
- 6:19SPEAKER_02: Absolutely.
- 6:20SPEAKER_01: We focus in on the parts that we're supposed to do day in and day out, but the code encompasses all aspects.
- 6:27SPEAKER_01: And the exam focuses on all aspects of the code.
- 6:32SPEAKER_00: So I'm I'm going back a little bit here, but I want to challenge a statement that you made, Charles, about the level two exam about a minor increase or a small increase in pain.
- 6:41SPEAKER_00: There is no such thing as small increases in pain with nice set.
- 6:45SPEAKER_00: There is always a significant increase in pain every time you take an exam.
- 6:49SPEAKER_00: And I think the exam that is the most difficult certainly causes the most people, the most pain is drumroll level three.
- 6:59SPEAKER_00: Level three.
- 7:01SPEAKER_00: Level three.
- 7:01SPEAKER_00: Yeah, I think you're holding up the wrong fingers.
- 7:03SPEAKER_00: It should be a one-finger salute for that exam.
- 7:06SPEAKER_00: But that exam.
- 7:07SPEAKER_00: If there's three of us, we could all do it at the same time.
- 7:10SPEAKER_00: There you go.
- 7:10SPEAKER_00: That's right.
- 7:11SPEAKER_00: So that exam, from our experience discussing with our students, and directly from NYSET, has the highest failure rate of all the exams that NYSET offers across all the categories.
- 7:25SPEAKER_00: Level three fire alarm.
- 7:27SPEAKER_00: Chris, why is the level three exam so challenging for people?
- 7:32SPEAKER_01: Well, level three, one of the one of the things that is a big challenge comes in the form of it's no longer about do you know how to do your job?
- 7:39SPEAKER_01: It is, do you know about the process of doing work and also other people's jobs?
- 7:46SPEAKER_01: It it gets more into the project management sections.
- 7:49SPEAKER_01: And it is stuff that after five years, because you gotta have five years of experience, nice at expects that you are in a position, that you are the lead technician of a job and you are in control and having the aspect of being a supervisor for all these other people.
- 8:08SPEAKER_01: And from an individual perspective, not everybody that's taking the level three exam is working in project management yet.
- 8:17SPEAKER_01: And you also don't get a book to take in, but it is worth about 30% of the exam, the project management side.
- 8:25SPEAKER_01: Now, they they do ease that a little bit with its project management as well as OSHA and field experience.
- 8:32SPEAKER_01: So basic electronics and your understanding of first aid, but in all seriousness, that 30% is majority project management, which after five years, not everybody's doing that.
- 8:45SPEAKER_01: And it is very, very difficult on that aspect of it.
- 8:49SPEAKER_01: Even the code stuff gets significantly deeper into it and aspects that I've never had to work with that.
- 8:58SPEAKER_01: Well, NISAT expects that by level three, this is the position that you're in, and that's just not necessarily how everybody out in the field transitions and moves.
- 9:08SPEAKER_00: Yeah.
- 9:09SPEAKER_00: And level three, as you you hit it right on the head with the five years.
- 9:12SPEAKER_00: I think that there's a huge expectation from NYSET because you're going from two years experience as a senior tech to five years as the top dog on the project.
- 9:22SPEAKER_00: And there is a huge jump in expectations from NYSET.
- 9:25SPEAKER_00: They really expect you to bring up your game.
- 9:27SPEAKER_00: And as you said, it's not only the project management, it's the code minutiae stuff, the NXF material from 72 and all the other, not just 907 from IBC, the other chap other stuff in chapter 9 from IBC let you know about smoke control and all this other stuff.
- 9:44SPEAKER_00: And it just boggles my mind the stuff that they pull out and talking to students.
- 9:49SPEAKER_00: And from your experience with it, I it just amazes me the questions that they come up with from that.
- 9:55SPEAKER_01: And another aspect is they they throw in NFPA 101.
- 9:59SPEAKER_01: Now, if you've been working in the field for a while, you're probably more familiar with it, but for people that got introduced to fire alarm starting like 2000s onward, the IBC is what's being used for the building code.
- 10:14SPEAKER_01: So it's another book that isn't real world used a lot and people are not as familiar with.
- 10:23SPEAKER_01: Right?
- 10:23SPEAKER_01: Yep, exactly.
- 10:25SPEAKER_00: So the good news about level three is that level four is just right around the corner.
- 10:33SPEAKER_00: It's one more exam.
- 10:34SPEAKER_00: And actually, while level three has the highest failure rate of all the exams, level four, I don't think I think I've only ever talked to one person who ever failed level four.
- 10:48SPEAKER_00: Everybody that I've talked to that eventually passed level three, and that we always encourage when you get that extra five years, because level four requires 10 years, go for level four.
- 10:56SPEAKER_00: The exam's very similar, and they allow a project management book in the NASCAR book, uh, project uh contractor's guide to business law and project management, basic additions allowed in the exam.
- 11:08SPEAKER_00: And I've only talked to one person that's ever failed level four.
- 11:12SPEAKER_00: Pretty much everybody else, they breeze through it because they already had all that tough learning they had at level three.
- 11:18SPEAKER_00: Now level four is like a breeze.
- 11:20SPEAKER_00: So that's why I say after you finish three, immediately start prepping for four.
- 11:25SPEAKER_00: If you've got the 10 years, go for four.
- 11:28SPEAKER_00: And the profile of a four is somebody who's kind of an office guy.
- 11:32SPEAKER_00: You are the senior top dog in the company.
- 11:36SPEAKER_00: And uh that you're usually in the office, you're managing multiple projects at once, you're interfacing at a high level on these projects with people.
- 11:45SPEAKER_00: It's not it's no longer the local thing that you're the one guy and you're the top dog in the site.
- 11:50SPEAKER_00: You're the top dog over multiple projects.
- 11:53SPEAKER_00: So that's generally been my experience with it.
- 11:56SPEAKER_00: Once you get past three and all the things you learn in three, level four generally is pretty easy.
- 12:00SPEAKER_00: So, guys, next thing I'd like to talk about from code today is NFTA 72, chapter 18, specifically 18.3, general requirements for notification appliances.
- 12:10SPEAKER_00: Just like in chapter 17 and 17.4, they have general requirements for initiating devices.
- 12:17SPEAKER_00: Well, there are some also also some uh general requirements for notification appliances.
- 12:22SPEAKER_00: Chris, you want to kick us off talking about some of that?
- 12:25SPEAKER_01: Well, with your notification, everything has to be listed for its purpose.
- 12:30SPEAKER_01: Everything from where's it gonna go?
- 12:33SPEAKER_01: Are we doing a wall mount?
- 12:34SPEAKER_01: Are we doing a ceiling mount?
- 12:35SPEAKER_01: Is it gonna be for indoor application, or is this gonna be a device for above the riser room?
- 12:41SPEAKER_01: Outdoor application.
- 12:43SPEAKER_01: Everything with notification has to be listed for purpose.
- 12:47SPEAKER_01: What it's being used for, how it's going to be utilized, where all of it has to be listed.
- 12:52SPEAKER_01: And and from a day-to-day perspective, somebody that's ordering this stuff, it's a notebrinder.
- 13:00SPEAKER_01: It's easy, it's easy stuff to do.
- 13:02SPEAKER_01: From a perspective of somebody that is looking at it as ran into the field, or even from a possibly like testing perspective, that's a whole lot of information all at once.
- 13:14SPEAKER_00: So, Charles, another requirement from 18.3 is a nameplate.
- 13:18SPEAKER_00: What the heck is a nameplate?
- 13:20SPEAKER_02: A nameplate is a plate that's permanently affixed or inscribed on the device that provides all of its electrical requirements.
- 13:33SPEAKER_02: And the thing with the notification appliance, we call it an appliance because it has uh higher power consumption rate than let's say a smoke detector does.
- 13:47SPEAKER_02: So uh the code uses the term appliance to indicate, hey, this is gonna draw more power.
- 13:54SPEAKER_02: We need those electrical requirements listed so we can identify what that power requirement is and how we're gonna meet it with uh the control of the system, adding an additional power supply or whatever the case may be.
- 14:10SPEAKER_00: Yep.
- 14:11SPEAKER_00: And one of the things that also lists too is electrical compatibility, whether it's DC or FWR powered, you know, full weight rectified, and most panels use DC, but you may run into an older panel that uses FWR, and the appliance has to be the nameplate has to indicate that it'll work with FWR.
- 14:28SPEAKER_00: So uh in order to be electrically compatible.
- 14:32SPEAKER_00: One of the uh interesting requirements, and to me, this is kind of a no-brainer, and but you know, there's a lot of stuff in the code that um to me seems like common sense, but I guess some because somebody did something that caused it to be in the code, it's kind of like for the instruction manual for my chainsaw.
- 14:50SPEAKER_00: It actually shows not sitting on a limb, on the outside of a limb, that you're cutting off the chainsaw.
- 14:55SPEAKER_00: And I couldn't believe they put that in the manual.
- 14:57SPEAKER_00: But I said, Well, you know why they put it in there?
- 14:59SPEAKER_00: Because somebody actually did that and sued the chainsaw manufacturer because they didn't tell them not to.
- 15:05SPEAKER_00: But this one's this one I love.
- 15:07SPEAKER_00: Non-fire alarm signals shall not say fire.
- 15:11SPEAKER_00: Could that cause confusion if somebody's using a signal for um, let's say, alerting people of breaks or you know, end of the workday or whatever, and if it's labeled fire and the people get confused and think it's actually a fire, could that be an issue?
- 15:26SPEAKER_00: Definitely.
- 15:28SPEAKER_01: Absolutely.
- 15:30SPEAKER_01: People a lot of times, so what I've noticed from working in inspection and testing is if people are in the building and the alarm goes off, the first thing that they do is look for where is it?
- 15:42SPEAKER_01: If they see it, see a sound go off and they see that it says fire, it's time to get out.
- 15:48SPEAKER_01: Now, also that same in that same uh line of thought, most people don't get out because you know, eh, it's fine, it's normal.
- 15:56SPEAKER_01: We all, you know, you can always tell the fire alarm technicians inside of a building when the alarm goes off because it's fine.
- 16:03SPEAKER_00: It's just a false alarm.
- 16:05SPEAKER_00: We don't have to go anywhere.
- 16:07SPEAKER_00: Charles, one of the interesting requirements in 18 that's also paralleled in 17, is uh appliances subject to damage require guards.
- 16:14SPEAKER_00: Why do we need to put a guard on a notification appliance?
- 16:18SPEAKER_02: Well, in case someone tries to rip it off, the guard can tackle them and and uh apprehend them so as to not damage the equipment.
- 16:27SPEAKER_02: A guard is a protective cover to make sure that uh equipment isn't physically damaged.
- 16:33SPEAKER_02: Um so in the event that we have an environment where physical damage could occur, we have a guard over our devices to make sure that doesn't occur.
- 16:43SPEAKER_02: The guard has to be properly listed so as not to interfere with the operation of the notification appliance.
- 16:50SPEAKER_02: We can't have uh uh an opaque cover over a strobe, for instance.
- 16:56SPEAKER_02: So the strobe has to be able to fulfill its function, the sounder has to be able to fulfill its notification function, and the guard cannot interfere with that.
- 17:08SPEAKER_02: That's why that listing is important.
- 17:11SPEAKER_00: When you said guard and you're telling that story, I was thinking about Paul Blart Molkop as being the guard for my notification appliance rolling around in the segue.
- 17:20SPEAKER_00: One interesting thing about uh the guards, too, is something I think a lot of people don't realize, is that for audible and visible notification, they can even the clear ones can have an impact on the sound output.
- 17:32SPEAKER_00: And uh they will list, they have to be listed with the appliance, but they also have to list what the impact is.
- 17:37SPEAKER_00: And a guard over an audible could reduce the sound level by 6 to 12 dB.
- 17:41SPEAKER_00: That's like doubling the distance twice.
- 17:44SPEAKER_00: Uh so that's a significant loss.
- 17:46SPEAKER_00: And for light intensity, you could lose anywhere from 15 to 45 candela of light intensity, even through a clear guard.
- 17:53SPEAKER_00: And that just it's just a matter of science.
- 17:56SPEAKER_00: You put a piece of glass in front of something or a piece of plastic, it does reduce the intensity.
- 18:01SPEAKER_00: And that's a pretty significant reduction.
- 18:03SPEAKER_00: So that could result in project calls for 75 candela.
- 18:07SPEAKER_00: If you're losing 30 candela through the uh through the uh guard, now you have to set the strobe at basically 105 to be able to make that 75 or some higher number, probably 115 or something like that.
- 18:21SPEAKER_00: But I mean, you have to increase the candela to compensate, and you have which will increase the current draw.
- 18:27SPEAKER_00: So it's definitely an important design consideration.
- 18:29SPEAKER_00: One of the things that I uh found interesting, Chris, I'd like to ask you about this one is about wiring properly to provide supervision.
- 18:38SPEAKER_00: And uh devices are pretty intuitive, modern devices are pretty intuitive, but sometimes people make shortcuts.
- 18:44SPEAKER_00: And uh, how important is that that devices be wired properly to provide supervision?
- 18:51SPEAKER_01: We are supervising the circuit with your notification appliances and not necessarily each of the appliances.
- 18:57SPEAKER_01: Now, that being said, we have to use each of those appliances as a pass-through for the circuit so we can read the underline resistor.
- 19:05SPEAKER_01: If you are not providing the correct installation of the wire through the actual appliance, cutting it, stripping back what you need, and utilizing the appliance itself as that pass-through for the current for the sorry the circuit to actually move through, you can take a device off and and you've got no issues if you don't do that.
- 19:28SPEAKER_01: And now you've got uh part of the building that's not protected through the notification.
- 19:36SPEAKER_01: So getting into what looks at as uh Annex F materials for a lot of that and understanding of that, you gotta have that correct one correct wiring method going through and the supervision.
- 19:49SPEAKER_01: You gotta have an N-aligned resistor for your notification circuit because we're not monitoring the device or appliances, we're monitoring the circuit.
- 19:59SPEAKER_00: Yep.
- 19:59SPEAKER_00: And if you wire the device wrong, you could defeat that supervision.
- 20:03SPEAKER_00: Well, guys, next thing I'd like to talk about question from the field What is the required completion document required completion documentation for a fire alarm system?
- 20:12SPEAKER_00: And what is the purpose of each of those pieces?
- 20:15SPEAKER_00: Chris, why don't you start us off talking about the owner's manual?
- 20:19SPEAKER_01: So the owner's manual is for the building owner so they understand how to operate their fire alarm system.
- 20:26SPEAKER_01: From a contractor's perspective, we go out, we do the installation of this system, and once it's completely installed, we're handing it over to the building owner.
- 20:37SPEAKER_01: Someone who has no idea anything about fire law.
- 20:40SPEAKER_01: And so we are putting together an owner's manual based upon how the system was installed, how it's supposed to operate, the equipment uh data sheets, as well as manufacturer's instructions.
- 20:53SPEAKER_01: All of those things get completed into an owner's manual so that the owner understands how to operate their system as well as reset and a lot of times the testing, how testing is supposed to go for their system.
- 21:06SPEAKER_01: And it's a very crucial piece of documentation to hand over.
- 21:10SPEAKER_01: Otherwise, they have no idea what it is that they have.
- 21:13SPEAKER_01: They have no idea what to do with it.
- 21:15SPEAKER_01: Absolutely.
- 21:16SPEAKER_01: Charles, what function do the record drawings perform?
- 21:20SPEAKER_02: That shows accurately how that system was properly installed from a diagram perspective.
- 21:30SPEAKER_02: So it shows what actual device positions are, what actual cable was run, and the the direction it was run.
- 21:38SPEAKER_02: So anyone looking at it in the future can see the original installation was completed this way.
- 21:47SPEAKER_02: So they can find every device, even duct detectors, Chris, and uh the work stations and heat detectors and everything else are indicated right on the record drawing.
- 22:00SPEAKER_02: Absolutely.
- 22:01SPEAKER_00: They used to call those record drawings something else.
- 22:04SPEAKER_00: They had a term that Charles and I remember, and Chris probably has some memory of.
- 22:07SPEAKER_00: What do they used to call them?
- 22:09SPEAKER_00: The Asbuilt.
- 22:11SPEAKER_00: As built, yeah.
- 22:13SPEAKER_00: That's uh the old school term.
- 22:15SPEAKER_00: They've been using record for a couple of years, but uh yeah, as built, as the system was built.
- 22:20SPEAKER_00: The record of completion is also part of it.
- 22:23SPEAKER_00: And the record of completion basically is a punch list, so to speak, of all the equipment and verified that the system was functionally tested.
- 22:31SPEAKER_00: So it's basically a punch list that said, all right, I did this, this, and this.
- 22:34SPEAKER_00: I tested all these functions.
- 22:36SPEAKER_00: Here's all the devices, here's all the statuses, everything I need to know about that system.
- 22:43SPEAKER_00: Chris, what about site-specific software?
- 22:46SPEAKER_01: Your site-specific software is the programming software for the panel itself.
- 22:52SPEAKER_01: It's all of the devices that are on that system and how they're to signal back to the panel.
- 22:58SPEAKER_01: In the event that this pull station activates, it is to send an alarm back to the panel, activate the notification appliances, send alarm off-site.
- 23:06SPEAKER_01: It is how that system was programmed.
- 23:09SPEAKER_01: And the building owner gets a copy of that, and a copy of it is also supposed to go to the record or yeah, the documentation cabinet itself.
- 23:20SPEAKER_01: It's for disaster recovery.
- 23:22SPEAKER_01: In the event something happens and the panel gets fried from, you know, an overcurrent or lightning strike, or it's Sunday and somebody decided they had too much fun Saturday night and drive through a wall.
- 23:35SPEAKER_01: That panel can be replaced.
- 23:38SPEAKER_01: We have that site-specific software to put on a new control unit, then put that, re- or install that, and have that system back up and running.
- 23:47SPEAKER_01: That's what your site-specific software is for.
- 23:49SPEAKER_01: And it's something that we hand over.
- 23:51SPEAKER_01: We hand it over after we are doing acceptance or as we're doing acceptance to with other documentation.
- 23:57SPEAKER_00: Does Annex A have any specifics as to the form that software should be in?
- 24:02SPEAKER_01: Um Annex A says it has to be on it has to be current and on non-rewritable media.
- 24:10SPEAKER_01: And one of the examples that they have for that is a CDR.
- 24:16SPEAKER_01: CDR.
- 24:18SPEAKER_01: Now, it's annex A material.
- 24:20SPEAKER_01: Most of the time, your AHJ is willing to accept whatever it is that we're willing to bring out, but the code does stipulate current and on non-rewritable media.
- 24:32SPEAKER_00: And that term you bring up is how I'd like to end this part of the discussion is to remind everybody that all of these documents are living documents.
- 24:40SPEAKER_00: That anytime we go and do a modification of the system, they all need to be updated.
- 24:45SPEAKER_00: You know, the owner's manual, if we change the way the system functions, we've got to change that.
- 24:49SPEAKER_00: If we move, add or delete devices, change to record drawings, do a new record of completion when we modify the system.
- 24:55SPEAKER_00: And most important of all, just in case somebody decides to drive through a wall, we need to update the site specific software.
- 25:03SPEAKER_00: And Chris, you hit that right on the head.
- 25:04SPEAKER_00: It needs to be current with the current configuration of the system.
- 25:09SPEAKER_00: Well, gentlemen, I want to thank you again for uh joining me today and having a very lively discussion about fire alarm.
- 25:16SPEAKER_00: For all our listeners out there, please remember to like and subscribe.
- 25:20SPEAKER_00: And we will see you all next time.
- 25:21SPEAKER_00: Thanks, Brian.