Latest / Civil Engineering Made Simple / Steel Design Guide: AISC Rehabilitation and Retrofit Guide [A Reference for Historic Shapes and Specifications]
Transcript
- 0:00Speaker 1: Welcome back to the deep Dive. Today, we are tackling
- 0:02Speaker 1: a monumental piece of guidance, the AISC Rehabilitation and Retrofit Guide.
- 0:07Speaker 1: That's Design Guide fifteen.
- 0:09Speaker 2: It's a big one and it's so critical for anyone
- 0:12Speaker 2: working on existing buildings.
- 0:13Speaker 1: Absolutely so for everyone listening. Your mission today is to
- 0:17Speaker 1: get a fast but really thorough understanding of how we
- 0:21Speaker 1: upgrade old structural steel buildings.
- 0:23Speaker 2: Right the principles, the history, and the technical methods you
- 0:28Speaker 2: actually use on site.
- 0:29Speaker 1: And you've framed this before as being almost like a forensic.
- 0:32Speaker 2: Engineer, it really is. I mean, you're not starting with
- 0:34Speaker 2: a blank slate. You're trying to marry modern demands, you know,
- 0:39Speaker 2: seismic loads, new occupancy loads, with materials and details that
- 0:43Speaker 2: could be one hundred years old.
- 0:44Speaker 1: So you have to know the old rule book before
- 0:45Speaker 1: you can apply the new one. You absolutely have got Okay,
- 0:48Speaker 1: let's start right there with that history. Yeah, it feels
- 0:50Speaker 1: like steel should just be steel, but the way we've
- 0:54Speaker 1: designed with it has obviously changed a lot. Just how
- 0:57Speaker 1: much have the basic rules shifted over the last century.
- 1:00Speaker 2: Oh, it's been a fundamental shift. We've gone from you know,
- 1:02Speaker 2: very simple empirical rules to these highly sophisticated probability based methods.
- 1:09Speaker 2: Early on in the twentieth century, AISC design just it
- 1:13Speaker 2: pointed to generic ASTM standards, things like A seven and
- 1:17Speaker 2: A nine for shapes, and the whole foundation of design
- 1:20Speaker 2: was something called allowable stress design ASD.
- 1:23Speaker 1: And what did ASD actually look.
- 1:25Speaker 2: Like back then, well, for decades it was just a
- 1:27Speaker 2: fixed conservative number. Starting around nineteen twenty three, the allowable
- 1:31Speaker 2: stress engineers used was just eighteen kIPS per square inch
- 1:34Speaker 2: eighteen KC eighteen.
- 1:36Speaker 1: That's it.
- 1:36Speaker 2: That was it. It did get a little bump in nineteen
- 1:39Speaker 2: thirty six up to twenty ksi, but it was a
- 1:41Speaker 2: very simple factor of safety approach.
- 1:43Speaker 1: Twenty kc feels so arbitrary now when you think about
- 1:46Speaker 1: all the different steal grades we have. When did that
- 1:48Speaker 1: start to change?
- 1:49Speaker 2: The real intellectual leap forward was in nineteen sixty three.
- 1:52Speaker 2: That's when we finally stopped using those fixed numbers and
- 1:54Speaker 2: started tying the allowable stress to the material's actual capacity,
- 1:58Speaker 2: specifically to its minimum yield stress what we call five matters.
- 2:02Speaker 1: Ah, So the design became responsive.
- 2:04Speaker 2: To the material exactly. Suddenly, your allowable stress was a proportion,
- 2:08Speaker 2: like say zero runs in sixty cents white. So if
- 2:10Speaker 2: you've got a stronger grade of steel, you could actually
- 2:12Speaker 2: use that extra strength in your design.
- 2:14Speaker 1: That makes perfect sense. But you mentioned a revolution after that,
- 2:17Speaker 1: tell us about LRFD.
- 2:19Speaker 2: So the introduction of load and resistance factor design LRFD
- 2:23Speaker 2: in nineteen eighty six, that was truly revolutionary. It was
- 2:26Speaker 2: a huge philosophical shift. How So, well ASD uses a
- 2:30Speaker 2: single safety factor for everything, LRFT splits it up. It
- 2:33Speaker 2: looks at limit states, you know, the points where a
- 2:35Speaker 2: structure actually fails, and it uses separate factors for loads
- 2:39Speaker 2: and for resistances.
- 2:40Speaker 1: And why is that separation so important?
- 2:42Speaker 2: Because it lets us quantify risks so much better. We
- 2:45Speaker 2: use load factors because loads are uncertain, and we use
- 2:48Speaker 2: resistance factors because material strength and fabrication can be uncertain.
- 2:53Speaker 2: LRFD gives us a much more rigorous, much more reliable
- 2:56Speaker 2: way to determine safety. It's just a smarter way to
- 2:58Speaker 2: use the material.
- 2:59Speaker 1: Okay, So moving from the big members to how they're
- 3:02Speaker 1: held together. Yeah, legacy fasteners. That's often the first shock
- 3:06Speaker 1: when you open up an old building. Rivets.
- 3:08Speaker 2: Rivets are everywhere in older structures, and their specifications are
- 3:12Speaker 2: long gone. AsTMa one forty one, for instance, was discontinued
- 3:16Speaker 2: way back in nineteen sixty seven. It was replaced by
- 3:19Speaker 2: a five oh two, which had three grades. But even
- 3:22Speaker 2: a five oh two that was discontinued without a replacement
- 3:25Speaker 2: in nineteen ninety nine.
- 3:26Speaker 1: Wow, So just over a quarter century ago you could
- 3:29Speaker 1: still technically specify a structural rivet.
- 3:32Speaker 2: You could, yeah, even if it was rare. And at
- 3:34Speaker 2: the same time, of course, bolts were taking over. We
- 3:36Speaker 2: started with, you know, the low strength carbon steel bolts
- 3:38Speaker 2: like a three oh seven, but the real game changer
- 3:41Speaker 2: was the adoption of high strength bolts a three twenty
- 3:44Speaker 2: five and a four ninety. They just dramatically improved what
- 3:46Speaker 2: we could do with connections.
- 3:48Speaker 1: This history is so critical, but it leads right to
- 3:51Speaker 1: the biggest challenge figuring out what you actually have. If
- 3:54Speaker 1: the drawings are gone, how do you know how strong
- 3:57Speaker 1: the steel is?
- 3:58Speaker 2: Right, And that's the archaeology part of the job. You
- 4:00Speaker 2: have to do some material testing. How much you do
- 4:02Speaker 2: really depends on how critical project is and what records
- 4:05Speaker 2: you have. And the guide gives really good practical advice here.
- 4:07Speaker 2: If you have to take a sample for a tensile test.
- 4:09Speaker 2: You take it from a low stress.
- 4:10Speaker 1: Area like the very tip of a beam.
- 4:12Speaker 2: Flange, exactly the flange tips, or maybe an external plate
- 4:16Speaker 2: edge somewhere. You're not compromising the main section.
- 4:18Speaker 1: Okay, So you get the lab report back. It gives
- 4:20Speaker 1: you a number for yield strength for five A. Can
- 4:23Speaker 1: you just plug that into your modern software? Uh?
- 4:25Speaker 2: Not quite. And this is a detail that really separates
- 4:28Speaker 2: this kind of forensic work from new design. Standard lab
- 4:32Speaker 2: tests are dynamic. They apply the load relatively quickly, and
- 4:36Speaker 2: that tends to report a yield stress that's a little
- 4:38Speaker 2: bit higher than the true static yield stress, which is
- 4:41Speaker 2: what we need for our calculations.
- 4:43Speaker 1: So the test results are skewed a little high. How
- 4:45Speaker 1: do you correct for that?
- 4:47Speaker 2: We use an estimation equation with something called the tri factor,
- 4:50Speaker 2: So five equals twime times five way, and the key
- 4:54Speaker 2: thing is knowing where the test sample came from. Before
- 4:56Speaker 2: about nineteen ninety seven, mill reports often use samples from
- 4:59Speaker 2: the web of the beam. For those, the tri factor
- 5:02Speaker 2: is ninety five.
- 5:03Speaker 1: Meaning you have to reduce the reported strengths by five percent.
- 5:06Speaker 2: You have to for more modern steel, where the sample
- 5:09Speaker 2: comes from the flange, the r factor is usually one
- 5:12Speaker 2: point zero, but that five percent could easily be the
- 5:15Speaker 2: difference between a passing or a failing check on an
- 5:18Speaker 2: old member. It's a critical detail, and.
- 5:20Speaker 1: It's not just the material strength. Is that you're also
- 5:22Speaker 1: dealing with shapes that don't exist anymore.
- 5:24Speaker 2: Oh, for sure, if you're in a mid century building,
- 5:27Speaker 2: you're almost guaranteed to find shapes that aren't rolled today.
- 5:29Speaker 2: Historic W shapes, S shapes. Oh.
- 5:32Speaker 1: Modern design tables are.
- 5:33Speaker 2: Useless, totally useless. That's why the tables in the guide
- 5:35Speaker 2: are priceless. They have all the geometric properties for these
- 5:39Speaker 2: legacy shapes W forty four's S twenty four's. You need
- 5:43Speaker 2: the area, the depth, sure, but critically you need the
- 5:47Speaker 2: torsional constant and the wolping constant seven dollars.
- 5:50Speaker 1: And why are those two so important for these old sections?
- 5:53Speaker 2: They're essential for checking stability, especially lateral torsional buckling. A
- 5:58Speaker 2: lot of older slender beam are really susceptible to that.
- 6:01Speaker 2: If you're going to reevaluate that beam or strengthen it,
- 6:04Speaker 2: you absolutely have to know it's ned days and two dollars.
- 6:07Speaker 2: Without them, you're just guessing, all right.
- 6:09Speaker 1: So once we know exactly what we're dealing with, we
- 6:12Speaker 1: can move into the actual retrofit. Let's talk about the basics.
- 6:15Speaker 1: How do we make beams and columns stronger.
- 6:18Speaker 2: For beams, it's usually pretty straightforward. You're typically adding cover
- 6:22Speaker 2: plates to increase the capacity, or if you're making a
- 6:25Speaker 2: composite beam with a new concrete slab, you'dweld on plates
- 6:29Speaker 2: and of course make sure you add the share connectors
- 6:31Speaker 2: before you pour.
- 6:32Speaker 1: The concrete columns though they always seem like a bigger headache,
- 6:35Speaker 1: especially if the building's still occupied.
- 6:37Speaker 2: They are. You reinforce them by welding on more plates
- 6:40Speaker 2: or sections, or by encasing them in concrete. But the
- 6:44Speaker 2: whole idea of reinforcing a column while it's underload, that's
- 6:48Speaker 2: been a source of a lot of debate among engineers
- 6:51Speaker 2: for years. What was the debate about, Well, some early researchers,
- 6:54Speaker 2: like Brown and Ricker, they were concerned that the initial
- 6:57Speaker 2: load on the column would affect how the new reinforcem
- 7:00Speaker 2: it worked. They thought it might make the design less efficient,
- 7:02Speaker 2: that you'd have to be overly conservative.
- 7:05Speaker 1: But the industry moved past that idea.
- 7:07Speaker 2: It did. A well known authority, Lambert Tall, did a
- 7:10Speaker 2: lot of work on this and basically stated that the
- 7:12Speaker 2: ultimate strength is effectively identical.
- 7:14Speaker 1: Identical whether you reinforce it underload or with no load.
- 7:18Speaker 2: That was the conclusion. Yeah, the ultimate strength is the same.
- 7:21Speaker 1: So if the final strength is the same, what were
- 7:24Speaker 1: the early concerns really about. Was it about safety during
- 7:27Speaker 1: the work? Like could it buckle while you're welding?
- 7:31Speaker 2: That is the key distinction. The concern isn't about the
- 7:34Speaker 2: final capacity, it's about the operational safety the process. And
- 7:38Speaker 2: that's why an engineer named tied laid out six things
- 7:41Speaker 2: you absolutely have to consider when you design this kind
- 7:44Speaker 2: of work.
- 7:44Speaker 1: Let's go through those because they sound critical, okay.
- 7:46Speaker 2: First, the nature of the loads, static or cyclic. Second,
- 7:51Speaker 2: the ratio of the load it's carrying now versus what
- 7:53Speaker 2: it was designed for. Third, the type and condition of
- 7:57Speaker 2: the steel. Fourth, the risk of local bucklings during the welding. Fifth,
- 8:02Speaker 2: the effect on the whole system's stability, and sixth, critically,
- 8:06Speaker 2: the safety factor you need during the operation itself.
- 8:09Speaker 1: That list really drives home that the process is a
- 8:12Speaker 1: design problem in itself.
- 8:14Speaker 2: Okay, let's shift from vertical load to earthquake performance. This
- 8:18Speaker 2: is where retrofitting gets really sophisticated, it is.
- 8:21Speaker 1: It's complex. You're usually dealing with one of four main
- 8:25Speaker 1: types of lateral systems. You've got your rigid fully restrained
- 8:29Speaker 1: moment frames, then you have partially restrained frames, and then
- 8:32Speaker 1: the two types of bracing concentric where all the lines
- 8:36Speaker 1: meet at a point and eccentric where they're offset to
- 8:39Speaker 1: create a link beam.
- 8:40Speaker 2: And in all these cases, especially in seismic zones, the
- 8:43Speaker 2: goal is dictylity, right. You want to avoid a brittle
- 8:46Speaker 2: fracture at all costs.
- 8:47Speaker 1: That's the whole game. It's about dissipating energy, and all
- 8:51Speaker 1: the modern retrofit concepts are about forcing that inelastic action,
- 8:54Speaker 1: that yielding to happen away from the column face.
- 8:58Speaker 2: Why away from the column face specifically, what's going on
- 9:00Speaker 2: there that's so brittle.
- 9:01Speaker 1: That's usually where you have the complete joint penetration or
- 9:04Speaker 1: CJPE weld. It makes the beam and column act like
- 9:07Speaker 1: one piece. But we saw on earthquakes like Northridge in
- 9:09Speaker 1: ninety four that those joints with older weld metals could
- 9:12Speaker 1: just snap. They were too stiff and couldn't handle the rotation.
- 9:15Speaker 1: So you need to create a structural fuz somewhere else.
- 9:18Speaker 1: Let's start with the most common one, the reduced beam
- 9:21Speaker 1: section the RBS.
- 9:23Speaker 2: The RBS is the ultimate structural fuse. People call it
- 9:26Speaker 2: the dog bone cut. You literally cut away a portion
- 9:30Speaker 2: of the beam flanges in a radius shape near the column.
- 9:33Speaker 1: It seems so counterintuitive. You're making the beam weaker.
- 9:36Speaker 2: You are, but you're making it weaker in a very
- 9:38Speaker 2: controlled way. You're forcing the plastic hinge, the spot that's
- 9:43Speaker 2: going to yield and absorb all that energy to form
- 9:45Speaker 2: right there in that weakened section safely away from the
- 9:49Speaker 2: brittle weld.
- 9:50Speaker 1: You're telling the building where to fail safely. What's the
- 9:52Speaker 1: minimum you have to do to modify a connection with
- 9:55Speaker 1: an RBS.
- 9:55Speaker 2: Well, the guides say, at a minimum, you've got to
- 9:58Speaker 2: make the RBS cut, usually on the bottom flange. You
- 10:00Speaker 2: have to replace the old CJP welds with new high
- 10:03Speaker 2: toughness weld metal, and really important, you have to remove
- 10:07Speaker 2: any old backing bars or weld tabs. They act as
- 10:10Speaker 2: stress risers where a crack could start.
- 10:12Speaker 1: Are the options that don't involve cutting the beam YEP.
- 10:15Speaker 2: Two main ones. First is a welded haunch. You weld
- 10:19Speaker 2: a tapered t section to the bottom of the beam.
- 10:21Speaker 2: It acts like a strut and again it pushes that
- 10:22Speaker 2: plastic hinge away from the column. The other is a
- 10:25Speaker 2: bolted bracket, which is a great non welded option.
- 10:28Speaker 1: A non welded solution must be attractive on a lot
- 10:31Speaker 1: of sites.
- 10:32Speaker 2: It is you use high strength bolts to attach a
- 10:34Speaker 2: bracket to the beam and the column. And there's a
- 10:37Speaker 2: fascinating little detail in the guide. It recommends putting a
- 10:40Speaker 2: thin brass shim between the bracket and the beam flange.
- 10:44Speaker 1: A brass shim why.
- 10:46Speaker 2: To prevent galling and noise under a seismic event. There
- 10:49Speaker 2: might be a tiny bit of slip between those steel surfaces,
- 10:53Speaker 2: and the brass shim helps manage that.
- 10:55Speaker 1: And finally, there's a strict rule about the weld metal
- 10:57Speaker 1: itself in these special moment frames.
- 10:59Speaker 2: Right is FEMA three fifty one is very clear. If
- 11:02Speaker 2: you have old CJP welds made with low toughness metal,
- 11:06Speaker 2: they must be gouged out completely and replaced with modern
- 11:09Speaker 2: high toughness weld metal. The safety of the whole system
- 11:12Speaker 2: depends on it.
- 11:12Speaker 1: Okay, so we've covered the history, the evaluation, the design.
- 11:17Speaker 1: What does this all mean for the contractor in the field,
- 11:19Speaker 1: the actual work seems full of variables.
- 11:22Speaker 2: Field work on a rehab is high stakes. Before you
- 11:25Speaker 2: even think about welding, you need a chemical analysis of
- 11:27Speaker 2: the old steel to figure out its weld ability, and
- 11:30Speaker 2: you have to develop a proper welding Procedure specification a WPS.
- 11:35Speaker 2: And if that analysis shows you're dealing with say cast
- 11:38Speaker 2: iron or wrought iron, you just don't weld. You find
- 11:41Speaker 2: another way.
- 11:42Speaker 1: And when you do weld, are there preferred methods?
- 11:45Speaker 2: Generally, fil a welds are preferred over groove welds. They're
- 11:49Speaker 2: easier to do well and easier to inspect, and the
- 11:51Speaker 2: design should always try to use flat or horizontal weld positions.
- 11:55Speaker 2: That's where you get the best quality and its most
- 11:57Speaker 2: economical insight. Prep is non negotiable, absolutely not all the
- 12:01Speaker 2: paint rust galonizing. It all has to come off, and
- 12:05Speaker 2: you can't weld on wet or frosty surfaces period.
- 12:08Speaker 1: What about when it gets cold.
- 12:09Speaker 2: The rules are strict. You can't weld if the steel
- 12:12Speaker 2: is below zero fahrenheit, and if it's between zero and
- 12:15Speaker 2: thirty two you have to preheat the steel to at
- 12:17Speaker 2: least seventy degrees and keep it there.
- 12:19Speaker 1: And that preheat is to prevent the weld from becoming
- 12:21Speaker 1: brittle exactly.
- 12:23Speaker 2: It drives out moisture and prevents rapid cooling.
- 12:25Speaker 1: Which brings us back to that loaded column problem. What
- 12:28Speaker 1: actually happens to the steel's strength when you heat it
- 12:31Speaker 1: up with a torch or a welder.
- 12:33Speaker 2: This is where the engineer of record has to do
- 12:35Speaker 2: a serious investigation. That heat temporarily reduces the yield, stress,
- 12:40Speaker 2: and strength of the steel right in that area. You
- 12:44Speaker 2: have to check the member stability during the operation. A
- 12:47Speaker 2: good rule of thumb that Tied suggested back in eighty
- 12:49Speaker 2: eight was to assume a one inch wide strip of
- 12:52Speaker 2: steel along the weld is just temporarily ineffective, So you.
- 12:56Speaker 1: Have to run the numbers on that smaller reduced section
- 12:58Speaker 1: to make sure it doesn't buckle one to the existing load.
- 13:01Speaker 2: That's exactly right, and that calculation tells you if you
- 13:03Speaker 2: need temporary shoring or some other kind of load reduction
- 13:07Speaker 2: to do the work safely.
- 13:08Speaker 1: This has been a phenomenal deep dive. We've gone from
- 13:11Speaker 1: eighteen k S standards all the way to modern seismic retrofitting.
- 13:16Speaker 2: It really is a fascinating field. Structural rehab is forensic engineering.
- 13:21Speaker 2: You're not just applying new codes, You're deciphering a century
- 13:25Speaker 2: of old ones to make a building safe for the
- 13:28Speaker 2: next century. And understanding those historical details, you know, the
- 13:32Speaker 2: Troue factor, the properties of old s shapes. That's every
- 13:36Speaker 2: bit is important as knowing how to design a new
- 13:38Speaker 2: RBS connection.
- 13:39Speaker 1: Fantastic. Okay for everyone who wants a final challenge from this,
- 13:42Speaker 1: let's go back to that debate about loaded columns. Even
- 13:45Speaker 1: though we know the ultimate strength is the same, the
- 13:48Speaker 1: operation itself is still a huge design challenge.
- 13:51Speaker 2: Right, So your challenge is to think about that operational safety.
- 13:54Speaker 2: What are the key risks an engineer has to analyze
- 13:56Speaker 2: and mitigate during the construction that go beyond just the
- 13:59Speaker 2: fire capacity calculation. What are the things that could fail
- 14:02Speaker 2: in the moment. That's what really needs your deepest thought.