Latest / PE-Energy Industrial Supply – Powering Industry Excellence / Appleton EFDB Factory Sealed Photocontrol: Dusk-to-Dawn Lighting Control for Hazardous Locations
Transcript
- 0:00Every time you flip a standard light switch in
- 0:02your home, you're basically creating a tiny,
- 0:06almost invisible lightning bolt right inside
- 0:08the wall. Yeah, that microscopic electrical arc
- 0:11when the contacts touch. Exactly. And I mean,
- 0:14in your living room, it's completely harmless.
- 0:17But imagine you are a maintenance and reliability
- 0:19engineer and your quote unquote living room is
- 0:23a massive petrochemical plant. Or a sprawling
- 0:25oil refinery, right? Right. In that environment,
- 0:28the atmosphere might be just thick with highly
- 0:31flammable vapors or combustible dust. So that
- 0:35one tiny everyday arc from a light switch turning
- 0:37on at dusk is no longer harmless. No, absolutely
- 0:42not. It's the potential trigger for a catastrophic
- 0:45facility leveling explosion. You are actively
- 0:48managing a continuous high stakes ignition risk
- 0:51because setting up outdoor lighting in a standard
- 0:54commercial lot That's practically a set it and
- 0:56forget it situation. But in a classified industrial
- 0:59environment, every single electrical component
- 1:02has to be engineered to prevent that exact doomsday
- 1:05scenario. OK, let's unpack this. Welcome to the
- 1:09deep dive. Today, we're focusing on one specific
- 1:12highly engineered piece of equipment designed
- 1:14to solve this exact nightmare. We are pulling
- 1:17apart the technical catalog for the Appleton
- 1:20EFDB series factory sealed photo controls. Yes,
- 1:23and our mission today is to take these excerpts
- 1:26and distill the product range, the crucial specifications,
- 1:29the material makeup, and of course the selection
- 1:31criteria. Right. The goal is to make sure that
- 1:34you, the engineer listening, can specify the
- 1:36precise variant for your hazardous applications
- 1:39without second -guessing a single detail. And
- 1:42just to establish the ground rules for today's
- 1:43analysis, we are pulling this information strictly
- 1:46from the Appleton technical catalog. Yeah, this
- 1:49is an environment where guesswork gets people
- 1:51hurt. So we're keeping this entirely factual.
- 1:53No rule of thumb assumptions. We are analyzing
- 1:56the exact numbers, ratings, and dimensions provided
- 1:58by the manufacturer. So I want to start by looking
- 2:01at the certifications because, wow, the catalog
- 2:05throws out a massive alphabet soup of compliance
- 2:07ratings right out of the gate. It really does.
- 2:10Yeah, it says these units are for dusk to dawn
- 2:11lighting in areas with flammable vapors, gases,
- 2:14or combustible dusts. And then it lists explosion
- 2:18proof and dust ignition proof ratings. Right.
- 2:21It covers NEC and CEC class 1, division 1 and
- 2:242 for groups BC and D. And then it also hits
- 2:28class 2, division 1 and 2 for groups E, F and
- 2:31G, as well as class 3. Oh, and it throws in NEMA
- 2:343, 7 BCD and 9 EFG for good measure. Which is
- 2:38a lot to take in. Yeah. So before we get totally
- 2:41lost in the acronyms, what does a class one,
- 2:44division one environment actually look like on
- 2:47a plant floor? Well, it's helpful to break that
- 2:49down because those classifications dictate the
- 2:51entire engineering philosophy of the device.
- 2:53So class one means we're dealing with flammable
- 2:56gases or vapors. Like chemical plants or refineries.
- 2:59Exactly. And class two would be combustible dusts,
- 3:03like you'd find in a grain elevator or maybe
- 3:05a coal handling facility. OK, so the class is
- 3:07basically the type of hazard. Correct. And then
- 3:10the division tells you how often that hazard
- 3:12is present. So Division 2 means the explosive
- 3:16gas or dust is only there if something goes wrong.
- 3:19Like a pipe ruptures or a seal breaks or something.
- 3:21Right, exactly. But Division 1 means that under
- 3:25normal, everyday operating conditions, that explosive
- 3:28atmosphere is just hanging out in the air. It's
- 3:30expected to be there. Which honestly makes the
- 3:32design of this photo control so wild to me. Because
- 3:35when I first read the word explosion proof, I
- 3:37just assumed it meant the enclosure was built
- 3:39like a tank to survive a bomb going off next
- 3:42to it. A lot of people assume that. Yeah, but
- 3:44reading the actual mechanism in the catalog,
- 3:46it's the exact opposite. It says it confines
- 3:49arcing of the device within the enclosure, preventing
- 3:52ignition of atmospheres. So, wait, the way I'm
- 3:56reading this, it actually allows the explosive
- 3:58gas to get inside the light switch? Yeah, that's
- 4:00the counterintuitive genius of explosion -proof
- 4:03design. I mean, you can't permanently keep gas
- 4:06out of an enclosure that has to breathe and operate
- 4:08in varying temperatures and pressures over decades.
- 4:11That makes sense, yeah. Eventually, that flammable
- 4:13vapor will seep inside. And when the sun goes
- 4:16down and that photocell clicks on, creating that
- 4:19tiny electrical arc you mentioned earlier, the
- 4:21gas inside the housing will ignite. Wait, really?
- 4:25So there's literally a small explosion happening
- 4:27inside the device? Yes. Every time. The device
- 4:31acts as a miniature blast chamber. It contains
- 4:34the internal explosion and absorbs the pressure
- 4:36wave. Oh, wow. But more importantly, those expanding
- 4:39hot gases have to escape somewhere, right? So
- 4:42the housing is designed with precisely machined
- 4:45threaded joints. As the superheated ignited gas
- 4:48is forced out through those threads, it gets
- 4:50squeezed and cooled. Oh, so it cools down before
- 4:53it gets out. Exactly. By the time it finally
- 4:55reaches the outside atmosphere, it's cooled down
- 4:57so much that it can no longer ignite the larger
- 5:00explosive environment surrounding the enclosure.
- 5:02That completely changes how I view these enclosures.
- 5:05It's not a shield at all. It's like a thermal
- 5:07choke point. A thermal choke point is a great
- 5:09way to describe it. But looking at the catalog,
- 5:12there's a massive operational claim tied to this
- 5:15factory sealed design. It explicitly states that
- 5:18because the arcing components are factory sealed
- 5:20inside, You don't need to add external ceiling
- 5:23fittings and ceiling compound at each conduit
- 5:25entrance. Right, which is huge for maintenance.
- 5:28Yeah, I've talked to maintenance guys who've
- 5:30had to, you know, mix that Chico ceiling compound,
- 5:34pack the fiber damn tight around the wires and
- 5:37pour those seals in the field and they despise
- 5:39it. Oh, it's a nightmare. It's messy. It takes
- 5:42forever. And if you mess up the pour, the system
- 5:44isn't safe. So are you telling me they can just
- 5:47stop pouring seals entirely if they use this
- 5:50unit? Ah. Well, you have to read the fine print
- 5:53very carefully there, because that is not a blanket
- 5:56rule. Oh, really? Yeah, this raises an important
- 5:58question. The catalog is highly specific about
- 6:01an exception. It's true that you get to skip
- 6:03pouring the seals for class one division one
- 6:05and two for groups C and D. And you can also
- 6:09skip it for class one division two group B. OK.
- 6:13But, and this is a big but. If you are installing
- 6:16this in a Class I Division I Group B environment,
- 6:20external seals must absolutely still be installed
- 6:22at each conduit entrance. Group B. Let me just
- 6:25make sure I'm following the groups here. Group
- 6:28D is usually propane. Group C is ethylene. Group
- 6:32B, that includes hydrogen, right? Yes, hydrogen
- 6:35or any gases with equivalent hazard levels. You
- 6:38see, hydrogen molecules are incredibly small.
- 6:40They leak easily. And when they ignite, they
- 6:42burn violently with intense explosive pressure.
- 6:46And a really fast flame propagation speed, right?
- 6:48Exactly. Oh, OK. So the miniature blast chamber
- 6:52we talked about might not be enough on its own
- 6:54to stop a hydrogen explosion from traveling back
- 6:56down the conduit pipe. That's the physical reality
- 6:58of it. The factory seal inside the EFDB unit
- 7:01is incredibly robust, but the physics of a group
- 7:04E gas just mandate that extra physical layer
- 7:07of isolation in the piping system. So you can't
- 7:09just see the words factory sealed on the box
- 7:11and assume it applies to every square inch of
- 7:13the refinery. Definitely not. OK, so the internal
- 7:18mechanics are handling the spark, but this thing
- 7:20also has to survive the physical environment.
- 7:23I mean, a petrochemical plant isn't exactly a
- 7:25controlled climate. Far from it. It's sitting
- 7:27outside. 24 -7, just getting battered. So I want
- 7:32to look at the environmental tolerance as the
- 7:34catalog lays out. Let's start with temperature.
- 7:37The Appleton EFDB series is rated to operate
- 7:39from minus 25 degrees Celsius up to plus 40 degrees
- 7:44Celsius. Right. So in Fahrenheit, we're looking
- 7:47at minus 13 degrees up to 104 degrees. That covers
- 7:51a massive geographic and seasonal spread. I mean
- 7:54you could have this installed at a facility freezing
- 7:56over in an Alaskan winter or you know baking
- 7:58in the midday heat of a Gulf Coast summer and
- 8:01the internal photocell will still function predictably
- 8:03to turn the lights on at dusk. Speaking of dusk,
- 8:07the specs note it turns on at one to three foot
- 8:09candles with a turn on to turn off ratio of one
- 8:13to three. Yes that's a very specific operational
- 8:15spec. It is, and I actually have a theory about
- 8:18that specific ratio and how it might cause a
- 8:21major headache if installed poorly, but I'm going
- 8:23to save that puzzle for the end. Fair enough.
- 8:26Right now, I'm looking at how this housing defends
- 8:28itself against corrosion. Chemical plants are
- 8:31notorious for eating metal alive. Salt spray,
- 8:34airborne chemicals, constant moisture. Why not
- 8:37just cast it in iron and slap some heavy industrial
- 8:40paint on it? Well, because paint will chip. And
- 8:43the moment it does, the underlying metal begins
- 8:45to rust. Which is why the finish on these units
- 8:48is a very deliberate, three -step metallurgical
- 8:50process. A triple -coat finish, the catalog says.
- 8:54Right. The catalog specifies that both the body
- 8:57and the cover feature this heavy -duty triple
- 8:59-coat finish. First, there's a zinc electroplate,
- 9:02then a chromate dip, and finally an epoxy powder
- 9:05coat. I'm looking at that process, and I have
- 9:07to ask, why three layers? What's the actual chemistry
- 9:11happening there? Why is the zinc electroplate
- 9:14even necessary if you're just going to cover
- 9:15it in epoxy anyway? That's a great question.
- 9:18The zinc basically acts as a sacrificial barrier.
- 9:22Sacrificial? Yeah. In the harsh reality of an
- 9:25industrial plant, a wrench is going to get dropped
- 9:27on this thing, or a scaffold pole is going to
- 9:29scrape it. It happens. If the surface gets scratched
- 9:32down to the bare metal, the zinc will actually
- 9:35oxidize and corrode before the underlying iron
- 9:38or aluminum can. Oh, wow. So it literally sacrifices
- 9:41itself to protect the structural integrity of
- 9:44the housing. Exactly. That makes a lot of sense.
- 9:46And the chromate, what does that do? So the chromate
- 9:49layer acts as a conversion coating. It passivates
- 9:52the zinc, stabilizing it, and creates this highly
- 9:55textured microscopic surface that the final layer
- 9:59can bond to chemically rather than just kind
- 10:01of sitting on top of it. Ah, I see. And then
- 10:03that final layer, the epoxy powder coat, that
- 10:06provides the primary heavy duty physical barrier
- 10:09against the corrosive chemicals in moisture.
- 10:12You really can see that obsession with field
- 10:14level details in the hardware they use, too.
- 10:17The catalog highlights corrosion resistant stainless
- 10:19steel hex head captive screws to hold the cover
- 10:22to the body. Captive screws are such a great
- 10:24feature. They really are. It's such a specific
- 10:27call out. But if you think about a maintenance
- 10:29worker. 50 feet in the air on a graded walkway
- 10:32wearing thick safety gloves. Oh yeah, trying
- 10:35to handle tiny hardware. Right. If they loosen
- 10:38a standard screw and drop it, it is going right
- 10:41through the grate and into the abyss. Captive
- 10:44screws stay permanently attached to the cover
- 10:46even when they're fully loosened. It's a tiny
- 10:49detail, but it prevents an operation from grinding
- 10:52to a halt over a lost piece of metal. It's the
- 10:54difference between equipment designed in a vacuum
- 10:57versus equipment designed for the reality of
- 11:00the field. You see that in the conduit connections
- 11:03too. Oh, the tapped hubs? Yeah, the bodies feature
- 11:06accurately tapped tapered hubs. When a worker
- 11:09threads the rigid conduit into that hub, the
- 11:12taper forces the threads to wedge tightly together,
- 11:15creating a rigid joint that maintains excellent
- 11:18ground continuity. And the catalog also mentions
- 11:21a smooth, rounded, integral bushing inside each
- 11:24of those hubs. I imagine that's to protect the
- 11:27conductor insulation as you're pulling the heavy
- 11:29wires through the pipe. Precisely. You definitely
- 11:32do not want to scrape the jacket off a wire inside
- 11:35a metal box and create a ground fault. Especially
- 11:37in an explosion -proof system. Exactly. Any nick
- 11:41in the wire insulation is a potential ignition
- 11:43source that you do not want to introduce. Right.
- 11:46So I want to pivot to the materials section because
- 11:49there is a specification here that really caught
- 11:51my attention. The bodies can be made of malleable
- 11:54iron or aluminum, and the covers are always aluminum.
- 11:58Correct. But the catalog doesn't just casually
- 12:01say aluminum. It specifically dictates copper
- 12:04-free aluminum, and it defines copper -free as
- 12:07a maximum of four -tenths of one percent copper.
- 12:11Yes. That is an incredibly tight metallurgical
- 12:14limit. Why is it so hyper -specific? fascinating
- 12:18here is that this is entirely about preventing
- 12:21galvanic corrosion. Galvanic corrosion? Yeah.
- 12:24In the presence of an electrolyte, which could
- 12:26be salt spray from the ocean or just, you know,
- 12:29industrial moisture in the air, two different
- 12:31metals will react with each other electrically.
- 12:34Standard industrial aluminum often uses copper
- 12:36as an alloying element to increase its physical
- 12:38strength. But if they are mixed together in the
- 12:41alloy, how do they react? I mean, they're the
- 12:43same piece of metal at that point. Well, On a
- 12:45microscopic level, the copper and the aluminum
- 12:48act like tiny batteries on the surface of the
- 12:50metal. Wait, really? Yeah. The aluminum becomes
- 12:54the anode, and the copper becomes the cathode.
- 12:56In that tiny battery circuit, the anode, which
- 12:59is the aluminum, will corrode away rapidly to
- 13:02protect the copper. So in a wet, salty environment,
- 13:06standard aluminum is essentially attacking and
- 13:08destroying itself. That is the practical result,
- 13:11yes. the surface would pit, flake, and degrade
- 13:14rapidly. So by strictly limiting the copper content
- 13:17to four tenths of one percent, Appleton neutralizes
- 13:21that internal galvanic reaction. Wow. The metal
- 13:24remains chemically stable, which is critical
- 13:26for an explosion proof rating. Those precisely
- 13:29machined flame paths and thread tolerances we
- 13:31talked about earlier, they have to remain pristine
- 13:34over decades of harsh exposure. If the threads
- 13:37corrode away, the blast chamber fails. Right,
- 13:40it's not just about physical strength, it's about
- 13:42molecular stability. All right, so we've dug
- 13:45deep into the ruggedness and the safety mechanics.
- 13:48Let's put ourselves in the shoes of the reliability
- 13:50engineer who is sitting at their desk looking
- 13:53at a set of blueprints for an upcoming facility
- 13:56expansion. Okay. How do they actually navigate
- 13:58this catalog to order the right unit? So selecting
- 14:02the correct variant comes down to a matrix of
- 14:04four primary variables. The first variable is
- 14:07the electrical requirement. the voltage and the
- 14:10amperage of the lighting circuit you're controlling.
- 14:12Okay, looking at the selection chart, there seem
- 14:14to be two main electrical tiers. You have the
- 14:16120 volt models, which operate at 50 or 60 Hertz
- 14:19and can handle a maximum of 8 .3 amps. Right.
- 14:22And then you step up to the higher voltage models
- 14:24covering 208 to 277 volts, also at 50, 60 Hertz.
- 14:30But those max out at a much lower 3 .5 amps.
- 14:33I noticed both of these tiers are rated to handle
- 14:35a maximum of 1 ,000 volt amps, or VA total. Exactly.
- 14:39Once you match your circuit voltage, the second
- 14:41variable is the wiring style of the enclosure
- 14:43itself. You have to evaluate the physical layout
- 14:46of your conduit run to choose between a dead
- 14:49-end configuration and a feed -through configuration.
- 14:52Okay, so the dead -end models use the prefix
- 14:55EFDB. That physically means there is only one
- 14:58hub on the box. The conduit comes in, the wire
- 15:01connects to the sensor, and the line stops right
- 15:03there. It is the literal dead -end of the run.
- 15:06Yes, exactly. But the feed -through models have
- 15:08the prefix EFDCB, adding that extra C. Those
- 15:13units have tapped hubs on opposite ends. So you
- 15:16can bring power into the sensor on one side and
- 15:19then continue the rigid conduit out the other
- 15:21side to feed power to another device further
- 15:22down the line. That's right. The third variable
- 15:25is the physical size of the conduit you're connecting
- 15:28to, which dictates your hub size. The catalog
- 15:30offers these units with hubs in one half inch,
- 15:33three quarter inch, or one inch sizes. And engineers
- 15:36really need to pay close attention to the dimensional
- 15:38drawings attached to those hub sizes. Oh, absolutely.
- 15:42I was looking at the schematics, and the overall
- 15:44size of the cast enclosure shifts slightly depending
- 15:47on the hub. For example, the total height of
- 15:49the unit, marked as a dimension A, is 136 .7
- 15:53millimeters for the one half inch and three quarter
- 15:56inch hub models. But if you step up to the one
- 15:58inch hub, that total height jumps to 139 .7 millimeters.
- 16:02Right, so it's a three millimeter difference.
- 16:04Right. At first glance, I thought, who cares
- 16:08about three millimeters on a sprawling petrochemical
- 16:10plant? Right. It sounds tiny. But then I thought
- 16:12about retrofitting. If a maintenance team is
- 16:15trying to squeeze a new sensor into an existing
- 16:17densely packed conduit rack or trying to mount
- 16:20it on a highly constrained custom bracket, those
- 16:23three millimeters could be the difference between
- 16:24the box fitting perfectly or the maintenance
- 16:27team having to spend hours rebending rigid pipe.
- 16:30That is exactly why dimensional tolerances are
- 16:32published down to the tenth of a millimeter.
- 16:35The final variable in the selection matrix is
- 16:38the material choice for the body. As we mentioned,
- 16:40you can choose between malleable iron or that
- 16:43copper -free aluminum. And the denotation in
- 16:45the catalog number is very straightforward, right?
- 16:48If you want the aluminum body, you just add an
- 16:50A to the very end of the part number. Yep, that's
- 16:52the formula. So, to put it all together, if I
- 16:56am specifying a 120 -volt dead -end unit with
- 17:00a 1 .5 -inch hub and I want it cast in iron,
- 17:03the catalog number is EFDB150PC120. But if I
- 17:10want that exact same configuration cast in aluminum,
- 17:13I just write EFDB150PC120 and stick an A on the
- 17:18end. You've got it. But perhaps the most strategic
- 17:21part of this entire catalog excerpt is a small
- 17:23section at the very bottom titled Replacement
- 17:26Parts for Remote Photo Control. Oh, yeah. You
- 17:29actually have the option to purchase just the
- 17:31complete cover assembly on its own. Yes. So what
- 17:34does this all mean? The catalog lists the EFKB
- 17:38-PC120 for the 120 volt systems and the EFKB
- 17:42-PC277 for the higher voltage systems. When I
- 17:47read that, the operational benefits just clicked
- 17:49for me. It's a game changer. The actual photocell
- 17:52sensor, the brain of the unit, is built entirely
- 17:55into that cover. These things sit outside. A
- 17:58sensor is eventually going to fail. Maybe a forklift
- 18:01kicks up a rock and smashes the glass, or the
- 18:04electronics just reach the end of their lifespan
- 18:06after a decade. Right. It happens to the best
- 18:09equipment. If they had to replace the whole unit,
- 18:11a technician would have to shut down the line,
- 18:13unthread rigid steel pipe, rip out the entire
- 18:16cast iron body, and rewire a brand new enclosure
- 18:19from scratch. Exactly. If we connect this to
- 18:22the bigger picture... Standardizing on these
- 18:25specific models allows a facility to drastically
- 18:28alter their maintenance, repair and operations,
- 18:30their MRO, inventory strategy. Because they don't
- 18:33have to keep the whole enclosures on the shelf.
- 18:35Right. A massive facility does not need to keep
- 18:38dozens of fully assembled heavy iron boxes taking
- 18:41up space in the warehouse. They can just standardize
- 18:44their installations and keep a few of these voltage
- 18:46specific EFKB cover assemblies in stock. So when
- 18:50a unit fails in the field. reliability engineer
- 18:53or a maintenance tech just grabs a new cover,
- 18:55walks out to the site, unscrews those four captive
- 18:58stainless screws, pulls the dead cover off, wires
- 19:01the new one in, and screws it back onto the existing
- 19:04body that's already plumbed into the conduit.
- 19:06Yep, it takes a complex multi -hour pipe fitting
- 19:08job and turns it into a 10 -minute component
- 19:11swap. That is incredible. And it does this while
- 19:13perfectly maintaining the explosion -proof integrity
- 19:16of the system because the flame paths and the
- 19:18factory seal are all maintained in the design
- 19:20of the cover. It really balances the extreme
- 19:24safety requirements of a classified environment
- 19:26with the very real practical pressures of a maintenance
- 19:28team trying to keep the plant operational. Let's
- 19:31take a moment to summarize the ground we have
- 19:33covered today. We started with the sheer danger
- 19:36of an everyday electrical arc in a petrochemical
- 19:38environment. Right. We looked at how the Appleton
- 19:41EFDB series neutralizes that threat by acting
- 19:44as a factory -sealed mini blast chamber that
- 19:47cools expanding gases through threaded joints.
- 19:50And we learned that while this design frees you
- 19:52from pouring external seals in many hazardous
- 19:55areas, you absolutely must still pour them for
- 19:58Class I Division I Group B environments because
- 20:00of the extreme volatility of gases like hydrogen.
- 20:03Yes. We also analyzed the rigorous environmental
- 20:06defenses required to survive in the field, from
- 20:09the broad operating temperature range of minus
- 20:1125 degrees to plus 40 degrees Celsius to the
- 20:15heavily engineered triple coat finish, combining
- 20:17a sacrificial zinc layer, chromate passivation,
- 20:20and an epoxy barrier. Yeah. And we broke down
- 20:22the chemistry behind galvanic corrosion, explaining
- 20:25why standard aluminum destroys itself and why
- 20:28Appleton strictly caps copper content at four
- 20:31-tenths of one percent. Exactly. Finally, we
- 20:34decoded the catalog matrix, outlining how engineers
- 20:37select the precise unit based on voltage, dead
- 20:40end versus feed through wiring, hub size tolerances
- 20:43down to the millimeter, and material choices,
- 20:46while highlighting the massive MRO inventory
- 20:48savings of stocking swappable complete cover
- 20:51assemblies. By mastering these specifications,
- 20:53you are ensuring a more efficient maintenance
- 20:55strategy, fewer poured seals where allowable,
- 20:59and uncompromised safety in your facility's most
- 21:01dangerous areas. Because the goal is always to
- 21:04provide engineers and reliability teams with
- 21:07the exact factual data they need to specify the
- 21:10correct component the very first time. Before
- 21:13we wrap up, I want to leave you, the listener,
- 21:15with a final puzzle to think about. I mentioned
- 21:18earlier that I had a theory about the light sensitivity
- 21:20specs. Ah, yes. The one to three foot candles.
- 21:23Right. Right. The catalog dictates that these
- 21:26units turn on at one to three foot candles. A
- 21:29foot candle is Basically just a measurement of
- 21:31how much light is falling on a surface. It also
- 21:35specifies a very exact turn on to turn off ratio
- 21:38of one to three. That ratio is a form of hysteresis.
- 21:42Hysteresis. Yeah, it means if the photocell triggers
- 21:44the lights to turn on when the ambient sunset
- 21:46light drops to one foot candle, it won't turn
- 21:49the lights off again until the sensor reads at
- 21:51least three foot candles of light. Oh, so it
- 21:53prevents the lights from flickering on and off
- 21:55if a dark storm cloud passes over at dusk. Exactly.
- 21:58But. Think about the precise physical placement
- 22:00of these photo controls in a dense, heavily illuminated
- 22:03refinery. Imagine a reliability engineer mounts
- 22:07an EFDB sensor on a pole to control a bank of
- 22:11pathway lights. But what if they accidentally
- 22:13install it too close to other high -output artificial
- 22:16lights in a neighboring sector of the plant?
- 22:20Could the sudden blast of light from a nearby
- 22:22high -mass luminaire turning on actually hit
- 22:24this sensor with more than three -foot candles
- 22:26of artificial light? It definitely could. If
- 22:29it does, it would trigger that one -to -three
- 22:31turnoff threshold. The sensor thinks the sun
- 22:33just came up, so it turns the pathway lights
- 22:35off. But when it turns the lights off, the ambient
- 22:39light drops back down to one foot candle. So
- 22:41the sensor turns back on. Which triggers the
- 22:43other lights to come on. You see where this is
- 22:45going. Could a perfectly specified explosion
- 22:48-proof sensor create an unintended facility -wide
- 22:52feedback loop of lights flickering on and off
- 22:54all night long? simply because it was bolted
- 22:56to the wrong side of a beam? A great physical
- 22:59placement question to ponder on your next facility
- 23:01site walk. It reinforces the idea that even with
- 23:05flawlessly engineered equipment, the human element
- 23:07of system design and physical placement remains
- 23:09the final critical variable in any reliable facility.
- 23:13Definitely something to mull over the next time
- 23:14you're reviewing a complex lighting plot or walking
- 23:17a site. Thank you for joining us for this deep
- 23:20dive into the Appleton EFDB catalog. Keep analyzing
- 23:23the data. Keep mastering the physical realities
- 23:26behind the numbers and never stop questioning
- 23:29the specs. Catch you next time.