Latest / Pharmacy Made Simple / Industrial Hygiene Evaluation Methods
Transcript
- 0:00Speaker 1: Welcome to the deep dive. Today, we're really getting into
- 0:03Speaker 1: the nuts and bolts of measurement with Bisessian Cones Industrial
- 0:07Speaker 1: Hygiene Evaluation Methods, second edition.
- 0:10Speaker 2: Yeah, this text is pretty much the go to guide.
- 0:13Speaker 2: Our goal here is to break down the core techniques
- 0:15Speaker 2: for you, especially if you're learning or starting out in
- 0:17Speaker 2: a technical field, maybe like pharmacy or environmental health.
- 0:21Speaker 1: We want to give you that solid practical understanding of
- 0:24Speaker 1: how these environmental hazards are actually measured and evaluated exactly.
- 0:29Speaker 2: We're focusing on the mechanics, the calculations, the stuff that
- 0:32Speaker 2: turns these invisible risks into actual numbers you can work with.
- 0:36Speaker 1: Okay, So to set the scene, let's talk about the
- 0:38Speaker 1: core idea and industrial hygiene. It's often called the tech.
- 0:42Speaker 2: Trat, right, that's the one. It's basically the whole strategy anticipation, recognition, evaluation,
- 0:48Speaker 2: and control. Think about it. You have to anticipate a hazard,
- 0:51Speaker 2: to recognize it.
- 0:52Speaker 1: Then recognize it, to evaluate it right.
- 0:54Speaker 2: To measure it. And you absolutely cannot control something if
- 0:57Speaker 2: you haven't evaluated it properly. So today, hey, we're zeroing
- 1:00Speaker 2: in on that evaluation piece, pillar three.
- 1:03Speaker 1: And it's important to Remember, like the book says, these
- 1:05Speaker 1: aren't just for you big industrial site.
- 1:08Speaker 2: Oh absolutely, these methods are used everywhere. Indoor air quality
- 1:11Speaker 2: in schools, noise in hospitals, even checking chemical storage in
- 1:16Speaker 2: a lab or pharmacy. It's broadly applicable.
- 1:18Speaker 1: So to evaluate first, you need to know what you're
- 1:20Speaker 1: looking for. The book breaks down hazards into four big groups.
- 1:24Speaker 2: YEP, physical, chemical, biological, and ergonomic factors. Let's tackle physical
- 1:30Speaker 2: agents first. These are all about energy.
- 1:33Speaker 1: Like sound.
- 1:34Speaker 2: Noise exactly, Noise is just pressure waves in the air, right,
- 1:38Speaker 2: defined by frequency, wavelength intensity. Too much energy transfer damage
- 1:42Speaker 2: is the ear, and.
- 1:43Speaker 1: That damage can be conductive or sensor neural.
- 1:46Speaker 2: Correct. Conductive is more mechanical outer or middle ear issues.
- 1:50Speaker 2: Sensor neural though, that's damage to the inner ear, the
- 1:52Speaker 2: cochlea or the nerve, usually permanent unfortunately.
- 1:55Speaker 1: Okay, Then there's radiation, starting with nonionizing right.
- 2:00Speaker 2: Non Yonionizing means not enough energy, specifically less than ten
- 2:03Speaker 2: electron volts to knock electrons off atoms, so no ions
- 2:07Speaker 2: are formed. Think UV visible light, infrared radio waves, even
- 2:11Speaker 2: those extremely low frequency fields ELF from power lines.
- 2:15Speaker 1: The sixty hertz stuff.
- 2:17Speaker 2: That's it. The main risk here is usually heat or vibration.
- 2:21Speaker 2: UV and IR can cause cataracts, microwaves and RF can
- 2:24Speaker 2: cause thermal stress.
- 2:26Speaker 1: And that link between ELF like the sixty hertz fields
- 2:29Speaker 1: and maybe some cancers.
- 2:30Speaker 2: Yeah, the tax mentions the suggested link, especially with leukemia.
- 2:34Speaker 2: It's still a complex area, lots of ongoing research, but
- 2:36Speaker 2: it's something hygeness are aware of.
- 2:38Speaker 1: Then the flip side, ionizing radiation. This does have enough
- 2:42Speaker 1: energy over ten ev to create ions.
- 2:45Speaker 2: And measuring it gets a bit tricky because we track
- 2:48Speaker 2: three different things. Okay, First there's exposure in the air
- 2:50Speaker 2: that's measured in erosions, then the energy actually absorbed by
- 2:53Speaker 2: your tissue, the physical dose measured in red or the
- 2:56Speaker 2: si unit gray.
- 2:58Speaker 1: And the third one that's.
- 2:59Speaker 2: The equivalent dose, which factors in the biological damage potential
- 3:02Speaker 2: of different radiation types measured in rem or sieverts. This
- 3:06Speaker 2: is usually the most relevant one for assessing health risk.
- 3:09Speaker 1: Got it. That system makes sense? Okay? Moving on to
- 3:13Speaker 1: category two. Chemical agents probably the most common workplace issue.
- 3:18Speaker 2: Very likely, yes, And the main ways chemicals get into
- 3:21Speaker 2: the body systemically are inhalation that's number one, and then
- 3:25Speaker 2: absorption through the skin.
- 3:26Speaker 1: And when we breathe them in. They can be in
- 3:27Speaker 1: different forms.
- 3:28Speaker 2: Right, two main types in the air aerosols, which are
- 3:31Speaker 2: tiny particles, and then actual gases or vapors.
- 3:35Speaker 1: Aerosols include things like dusts, fiberschrists.
- 3:38Speaker 2: Fumes you know, like welding fumes, and smoke, all basically
- 3:42Speaker 2: solid or liquid particles suspended in air.
- 3:45Speaker 1: And we classify chemical hazards based on their main danger toxic, flammable, corrosive, reactive.
- 3:51Speaker 2: And this is crucial. The book points out that any
- 3:53Speaker 2: chemical is toxic at a high enough dose, so things
- 3:56Speaker 2: that are flammable or corrosive are also toxic. They just
- 3:59Speaker 2: have those extra immediate dangers too.
- 4:00Speaker 1: Makes sense. What are what biological agents bioerosols?
- 4:04Speaker 2: These are your microbes, bacteria, fungi, viruses. They cause harm
- 4:08Speaker 2: through infection, allergies, or sometimes the toxins they produce.
- 4:11Speaker 1: And you measure them in CFU per cubic meter colony
- 4:15Speaker 1: forming units.
- 4:16Speaker 2: Usually yes cfu per cubic meter, after you collect them
- 4:19Speaker 2: on some kind of nutrient eggar plate or filter and
- 4:22Speaker 2: see what grows.
- 4:23Speaker 1: Why is sampling for those so difficult? Is it just
- 4:26Speaker 1: counting them?
- 4:26Speaker 2: It's more than counting the big challenge is viability figuring
- 4:30Speaker 2: out what's alive and infectious versus what's dead but still
- 4:33Speaker 2: allergenic or toxic. You need methods that can capture both aspects,
- 4:38Speaker 2: which makes interpreting the results well, it's complex.
- 4:41Speaker 1: Okay, so that covers the what. But knowing what the
- 4:44Speaker 1: hazard is isn't always enough, especially if the effects build
- 4:47Speaker 1: up over time. We need strategies to measure that exposure exactly.
- 4:51Speaker 2: This brings us to the how the monitoring strategies. Two
- 4:55Speaker 2: main approaches based on time. First is instantaneous sampling or
- 4:59Speaker 2: grab sampling quick check. Yeah, really short collection time seconds
- 5:02Speaker 2: maybe up to ten minutes. Often uses a direct reading instrument,
- 5:05Speaker 2: great for screening, checking for leaks or catching peak exposures.
- 5:08Speaker 2: And the other type that's integrated sampling. This is the
- 5:12Speaker 2: standard for assessing chronic exposure. You collect the sample continuously
- 5:16Speaker 2: over a long time, typically a full work shift like
- 5:18Speaker 2: eight hours.
- 5:19Speaker 1: But you don't get instant results.
- 5:20Speaker 2: No, usually needs lab analysis, but the payoff is huge.
- 5:24Speaker 2: You get a time weighted average the TWA.
- 5:27Speaker 1: AH, the TWA that's fundamental for compliance.
- 5:30Speaker 2: Right absolutely, most exposure limits are PWAs. The calculation is
- 5:34Speaker 2: basically you take each concentration you measured, multiply it by
- 5:38Speaker 2: the time spent at that concentration, some all those up,
- 5:41Speaker 2: and then divide by the total time period, like.
- 5:43Speaker 1: Four hundred and eighty minutes for an eight hour shift.
- 5:45Speaker 2: Precisely, it gives you that overall average exposure level, smoothing
- 5:49Speaker 2: out the highs and lows.
- 5:50Speaker 1: So how do we actually do this integrated sampling? What
- 5:53Speaker 1: are the mechanics?
- 5:54Speaker 2: Most common is active flow sampling. You use a pump,
- 5:57Speaker 2: usually battery powered, to pull a known volume of air
- 6:00Speaker 2: through a.
- 6:00Speaker 1: Collection medium like a filter for dust.
- 6:03Speaker 2: Exactly, or a servant tube for catching vapors. Then there's
- 6:06Speaker 2: surface sampling using wipes or swabs on surfaces. Standard practice
- 6:11Speaker 2: is often wiping a one hundred square centimeter area for chemicals,
- 6:14Speaker 2: maybe just one square centimeter from microbes.
- 6:16Speaker 1: And bulk sampling.
- 6:18Speaker 2: That's when you collect a chunk of the actual material,
- 6:20Speaker 2: could the insulation suspected of containing asbestos, a sample of
- 6:24Speaker 2: liquid solvent, or even capturing a volume of air directly
- 6:28Speaker 2: into a canister.
- 6:29Speaker 1: Okay, let's get specific. Evaluating airborne particles, how do we
- 6:33Speaker 1: measure total particulate?
- 6:34Speaker 2: So for total particulate it's typically integrated sampling. You use
- 6:38Speaker 2: a pump pulling air through a preweight filter, often a
- 6:42Speaker 2: thirty seven millimeter PVC.
- 6:43Speaker 1: Filter, preweight being the key.
- 6:45Speaker 2: Absolutely, it's a gravimetric method, meaning based on weight. The
- 6:49Speaker 2: filter must be desicated completely, dried in a controlled environment,
- 6:52Speaker 2: weighed precisely, then used for sampling, then desicated again and reweighed.
- 6:57Speaker 1: And the difference in weight is the mass collected correct.
- 7:00Speaker 2: Let's say in milligrams. Then you divide that mass by
- 7:03Speaker 2: the total volume of air you sampled, which you know
- 7:05Speaker 2: from the pump's flow rate and the sampling time to
- 7:08Speaker 2: get the concentration in milligrams per cubic meter mgmgm. If
- 7:13Speaker 2: you don't desiccate properly moistur weate messes everything up.
- 7:16Speaker 1: Okay, what about respirable particulate, the stuff that gets deep
- 7:19Speaker 1: into the lungs.
- 7:20Speaker 2: That requires size selective sampling. We only want the smaller particles,
- 7:25Speaker 2: So you add a device in front of the filter,
- 7:28Speaker 2: usually a cyclone, like the common door alliver model. It
- 7:31Speaker 2: spins the air and only particles below a certain size
- 7:34Speaker 2: make it through to the filter.
- 7:35Speaker 1: And you mentioned precision is critical here.
- 7:37Speaker 2: Extremely that door all over cyclone, for instance, is designed
- 7:40Speaker 2: to work correctly only at a specific flow rate one
- 7:43Speaker 2: point seven liters per minute plus or minus just five percent.
- 7:47Speaker 1: Wow, that's tight. What if the flow rate is off,
- 7:49Speaker 1: say ten percent too high or low.
- 7:51Speaker 2: Then the size cut point changes dramatically. If it's too low,
- 7:54Speaker 2: you collect particles that are too big, overestimating the respirable fraction.
- 7:59Speaker 2: If it's too high, you might miss some of the smaller,
- 8:01Speaker 2: truly respirable particles, underestimating the real risk. Either way, your
- 8:06Speaker 2: result is invalid for assessing that specific lung hazard flow
- 8:10Speaker 2: calibration is non negotiable.
- 8:12Speaker 1: Makes sense? Okay, let's switch gears to organic gases. In vapors.
- 8:16Speaker 1: We use sorbent tubes.
- 8:17Speaker 2: Right, Usually glass tubes packed with an absorbent material. Activated
- 8:22Speaker 2: charcoal is the workhorse for most non polar organics, things
- 8:25Speaker 2: with boiling points over one hundred degrees C. For more
- 8:28Speaker 2: polar stuff, you might use silica gel.
- 8:31Speaker 1: And there's a check for breakthrough.
- 8:33Speaker 2: Yes, super important. These tubes have two sections of absorbent,
- 8:37Speaker 2: a main front section, say one hundred milligrams, and a
- 8:40Speaker 2: smaller back section, maybe fifty milligrams, separated by foam or wool.
- 8:44Speaker 1: The back section is like a backup.
- 8:46Speaker 2: Exactly after sampling, both sections are analyzed separately. If the
- 8:49Speaker 2: amount of chemical found on the back section is more
- 8:51Speaker 2: than ten percent of the amount on the front section,
- 8:54Speaker 2: it means the front likely got saturated and chemical broke
- 8:57Speaker 2: through to the back.
- 8:57Speaker 1: So if the back section has say a leg seven
- 9:00Speaker 1: percent of the front's mass, what does that tell you
- 9:04Speaker 1: is the sample useless?
- 9:05Speaker 2: It tells you the front section was overloaded and you
- 9:08Speaker 2: definitely lost some contaminant out the back end during sampling,
- 9:12Speaker 2: So the actual concentration in the air was higher than
- 9:14Speaker 2: what you measured. The sample is technically invalid for compliance,
- 9:19Speaker 2: but it's a clear signal that exposure was significant and
- 9:21Speaker 2: you need to act fast to reduce it. You know,
- 9:24Speaker 2: the level was at least what you measured.
- 9:25Speaker 1: And how are these vapor samples analyzed?
- 9:27Speaker 2: Primarily gas chromatography GC. First you have to get the
- 9:31Speaker 2: chemical off the sorbent, usually by washing it with a
- 9:33Speaker 2: solvent like carbon disulfide for charcoal. Then you inject a
- 9:37Speaker 2: tiny bit of that solution into the GC.
- 9:39Speaker 1: What happens inside the GC.
- 9:41Speaker 2: Well, there's a carrier gas like helium or nitrogen that
- 9:44Speaker 2: pushes the sample through a long, thin column. Different chemicals
- 9:48Speaker 2: travel through the column at different speeds based on their properties.
- 9:51Speaker 2: A detector at the end sees each chemical as it.
- 9:54Speaker 1: Comes out, identifying them by when they come.
- 9:56Speaker 2: Out right, by their retention time and the size of
- 9:58Speaker 2: the detector signal. The peak area tells you how much
- 10:01Speaker 2: is there, usually by comparing it to calibration standards, and often.
- 10:04Speaker 1: Results are in mgm but need to be converted to
- 10:07Speaker 1: ppm parts per million.
- 10:09Speaker 2: Very common, yes, especially for vapors. There is a standard
- 10:13Speaker 2: formula using the substance's molecular weight and the molar volume
- 10:17Speaker 2: of a gas that constant twenty four point four to
- 10:19Speaker 2: five at standard temperature and pressure. It's a necessary conversion
- 10:23Speaker 2: for comparing to many exposure limits.
- 10:25Speaker 1: Okay, last specific method sound levels noise evaluation.
- 10:29Speaker 2: For personal exposure, we use audiodcimmeters. Little device is worn
- 10:33Speaker 2: by the worker, usually near the shoulder in the hearing zone.
- 10:36Speaker 2: They measure and integrate sound pressure levels continuously over the
- 10:39Speaker 2: measurement period.
- 10:40Speaker 1: And the standard like the OSHA standard uses ninety dba
- 10:44Speaker 1: for eight hours.
- 10:44Speaker 2: That's the criterion level. Yes, yeah, ninety dba twa for
- 10:48Speaker 2: eight hours, and critically it uses a five decibel exchange
- 10:51Speaker 2: rate or doubling rate. Meaning for every five DBA increase
- 10:55Speaker 2: in noise level, the allowable exposure time gets cut in half.
- 10:58Speaker 2: So at ninety five DBA, the allowed time is only
- 11:00Speaker 2: four hours. At one hundred DBA it's two hours.
- 11:03Speaker 1: And so on, and the docimmeter calculates a total dose.
- 11:06Speaker 2: Based on that exactly. It tracks the noise levels second
- 11:10Speaker 2: by second, calculates the partial dose for each level based
- 11:13Speaker 2: on the allowable time, and sums it all up to
- 11:15Speaker 2: give you a final dose percentage for the whole monitoring period.
- 11:18Speaker 2: One hundred percent dose means you've reached the equivalent of
- 11:21Speaker 2: eight hours at ninety DBA.
- 11:23Speaker 1: Got it. Before we wrap up, we could touch on
- 11:25Speaker 1: ergonomic evaluation again Briefly. It's not just chemical or physical energy, right.
- 11:30Speaker 2: Ergonomics is about the fit between the person and their
- 11:33Speaker 2: work environment. Evaluation involves measurements anthropometry like measuring someone's seated
- 11:38Speaker 2: eye height, elbow rest height, even popateal height.
- 11:42Speaker 1: That's the back of the knee height, yep.
- 11:44Speaker 2: And comparing those body measurements to the dimensions of the workstation,
- 11:47Speaker 2: chair height, keyboard positions, screen distance, the.
- 11:50Speaker 1: Goal being to minimize awkward postures and strain.
- 11:53Speaker 2: Precisely, it's about preventing musculoskeletal disorders, reducing discomfort, and ultimately
- 11:58Speaker 2: improving efficiency and well being. Poor ergonomic fit leads to
- 12:02Speaker 2: injuries and lost time.
- 12:04Speaker 1: And finally, all this evaluation leads to controls, often including
- 12:08Speaker 1: ppe personal protective equipment like.
- 12:11Speaker 2: Respirators, and with respirators, the absolute key is fit testing.
- 12:15Speaker 2: A respirator doesn't protect if it doesn't seal to the face.
- 12:18Speaker 2: Two types of fit tests generally yes. Qualitative, which is subjective,
- 12:24Speaker 2: relies on the wearer detecting a test agent by taste
- 12:27Speaker 2: or smell, like banana oil or saccharine solution. It's a
- 12:31Speaker 2: pass fail based on their senses.
- 12:32Speaker 1: And quantitative that's objective.
- 12:34Speaker 2: It uses an instrument, usually a particle counter, to actually
- 12:38Speaker 2: measure the leakage into the mask while the person performs exercises.
- 12:42Speaker 2: It generates a numerical.
- 12:43Speaker 1: Fit factor is one better than the other.
- 12:45Speaker 2: Quantitative is considered more reliable, and it's required for respirators
- 12:48Speaker 2: that need a higher level of protection, specifically anything with
- 12:52Speaker 2: an assigned protection factor PF greater than ten. It gives
- 12:55Speaker 2: you a number, not just a yes no feeling Okay.
- 12:58Speaker 1: So we've covered a lot. The hazard CAB categories the
- 13:00Speaker 1: sampling strategies like grab versus integrated, and deep dives into
- 13:04Speaker 1: evaluating particulates, vapors, and noise using specific tools like cyclones,
- 13:10Speaker 1: sorbent tubes, gcs, decimeters, And the.
- 13:12Speaker 2: Crucial point linking at all is that evaluation isn't just
- 13:16Speaker 2: data collection, it's proactive. The numbers you get, the TWA,
- 13:20Speaker 2: the noise dose, the fit factor, seeing breakthrough on a tube,
- 13:24Speaker 2: these are your triggers for action.
- 13:25Speaker 1: You use the data to implement controls before people get
- 13:29Speaker 1: sick or injured.
- 13:30Speaker 2: Exactly. The evaluation drives the prevention. That's the whole point, right.
- 13:33Speaker 1: To help solidify some of this, especially the calculation side,
- 13:36Speaker 1: here's a quick review exercise for you, our listener. Imagine
- 13:39Speaker 1: you did integrated air sampling for benzene vapor. Benzene's molecular
- 13:43Speaker 1: weight is seventy eight grams per.
- 13:45Speaker 2: Mole and let's say your lab report comes back telling
- 13:47Speaker 2: you that you collected a total of more point five
- 13:49Speaker 2: to five milligrams of benzene from an air sample volume
- 13:52Speaker 2: of point zero two four cubic meters.
- 13:54Speaker 1: Your challenge calculate the concentration of benzene vapor in parts
- 13:58Speaker 1: per million ppm.
- 13:59Speaker 2: Remember the hint. You'll first calculate the concentration in milligrams
- 14:02Speaker 2: per cubic meter MGM, and then use the formula PPM
- 14:06Speaker 2: equals concentration in mgm times twenty four point four to
- 14:09Speaker 2: five divided by the molecular weight, which is seventy eight
- 14:12Speaker 2: for benzene. Give it a shot. It brings to the
- 14:14Speaker 2: measurement and the conversion we talked about. Keep digging into
- 14:16Speaker 2: that data.