Latest / Civil Engineering Made Simple / Wind Loads: Guide to the Wind Load Provisions of Asce 7-16 (Asce Press)
Transcript
- 0:00Speaker 1: You know, usually when we think about a building failing,
- 0:02Speaker 1: I mean we just picture gravity winning, right, Yeah. Absolutely,
- 0:05Speaker 1: it's a very very vertical, predictable problem. You calculate the
- 0:09Speaker 1: weight of the concrete, the steel, you know, the people inside.
- 0:13Speaker 2: Right, the live and dead loads.
- 0:14Speaker 1: Exactly, and you design columns to transfer that weight straight
- 0:18Speaker 1: down into the earth. Because gravity is always on and
- 0:21Speaker 1: while it always points down, it.
- 0:22Speaker 2: Is comforting in a way. You know, we like forces
- 0:26Speaker 2: to be visible and static totally. When you're designing for gravity,
- 0:30Speaker 2: you can clearly trace the load paths from the roof
- 0:34Speaker 2: down to the foundation. It's neatly categorized.
- 0:37Speaker 1: But then then you step into the world of aerodynamics,
- 0:40Speaker 1: you start dealing with wind loading, and suddenly all that
- 0:43Speaker 1: predictability just vanishes.
- 0:45Speaker 2: It really does.
- 0:46Speaker 1: We're no longer just holding things up. We are trying
- 0:48Speaker 1: to make a rigid structure with stand this invisible, chaotic
- 0:52Speaker 1: fluid that is constantly changing direction, changing pressure speed.
- 0:57Speaker 2: Oh yeah, designing for wind is well, it's the absolute
- 1:00Speaker 2: definition of designing.
- 1:01Speaker 1: For chaos, right, because keeping a building standing against one
- 1:05Speaker 1: hundred and forty eight mile per hour wind gust requires
- 1:08Speaker 1: this fascinating, honestly kind of messy blend of meteorology and
- 1:13Speaker 1: structural mechanics.
- 1:14Speaker 2: You're fighting a dynamic enemy. I mean the air is
- 1:16Speaker 2: literally bending around the building. It's accelerating at the corners,
- 1:20Speaker 2: creating vacuums on the roof. It changes its behavior by
- 1:23Speaker 2: the millisecond.
- 1:24Speaker 1: So today, for you the listener, we are doing a
- 1:27Speaker 1: complete deep dive into how engineers actually tame that chaos.
- 1:32Speaker 2: It's a great topic.
- 1:33Speaker 1: We're looking at the ASSE seven sixteen wind load provisions. Specifically,
- 1:38Speaker 1: we're guided by the breakdown written by structural engineers William L.
- 1:42Speaker 1: Colburn and T.
- 1:43Speaker 2: Eric Stafford, right, the guide to the windload Provisions.
- 1:45Speaker 1: Our mission today is to understand the physics of aerodynamic
- 1:48Speaker 1: building design, stripping away, you know, the heavy jargon, to
- 1:52Speaker 1: focus on the why and the how behind all this math.
- 1:55Speaker 2: And that why is critical because simply memorizing a formula
- 1:58Speaker 2: is one thing, But truly understanding the physical reality that
- 2:02Speaker 2: the equation represents that is what makes you a competent engineer.
- 2:06Speaker 2: The math is just a language we use to describe
- 2:08Speaker 2: how the sky's trying to tear a building apart.
- 2:10Speaker 1: Okay, let's unpack this before we can even begin to
- 2:13Speaker 1: calculate how wind hits a physical wall. We first have
- 2:16Speaker 1: to figure out how fast the wind is actually blowing
- 2:19Speaker 1: in a given location.
- 2:20Speaker 2: Right right, You need your baseline and looking.
- 2:22Speaker 1: At the updated ASSE standard, the engineering community made this
- 2:27Speaker 1: massive fundamental shift in how we map those baseline wind speeds.
- 2:32Speaker 2: It was a huge paradigm shift. So historically engineers used
- 2:36Speaker 2: a basic wind speed map based on a fifty year
- 2:39Speaker 2: mean recurrence interval.
- 2:41Speaker 1: A fifty year interval.
- 2:42Speaker 2: Yeah, that meant you were designing for a wind event
- 2:45Speaker 2: that statistically had well a two percent chance of being
- 2:48Speaker 2: exceeded in any single year.
- 2:50Speaker 1: But they completely changed that.
- 2:51Speaker 2: They did the standard totally tossed out that blanket fifty
- 2:54Speaker 2: year interval. Now the wind speed maps are tied directly
- 2:57Speaker 2: to the building's risk category, which means which means you're
- 3:00Speaker 2: looking at mean recurrence intervals of three hundred, seven hundred,
- 3:03Speaker 2: seventeen hundred and three thousand years.
- 3:05Speaker 1: Wow. Okay, so wait, how do those match up with
- 3:08Speaker 1: the building types?
- 3:09Speaker 2: Well, the intervals match up with risk categories I through four.
- 3:13Speaker 2: So a minor agricultural storage shed that's category.
- 3:16Speaker 1: One, right, So that's the three hundred year map exactly.
- 3:20Speaker 2: A standard office building is category two. A crowded theater
- 3:23Speaker 2: where lots of people gather is category three, and essential
- 3:26Speaker 2: facilities like your hospitals or police stations, those are category three.
- 3:30Speaker 1: So designing a risk category for structure like a hospital
- 3:34Speaker 1: is like planning for a three thousand year storm event,
- 3:37Speaker 1: whereas a minor storage shed is just a three hundred
- 3:40Speaker 1: year event. We aren't changing the physics of the wind,
- 3:43Speaker 1: We're just shifting our statistical risk tolerance based on what's
- 3:46Speaker 1: inside the building.
- 3:47Speaker 2: Right. What's fascinating here is that this limited state approach
- 3:50Speaker 2: provides a consistent probability of load occurrences.
- 3:53Speaker 1: So wait, I have to challenge this because if we're
- 3:55Speaker 1: jumping from a fifty year map to a three thousand
- 3:58Speaker 1: year map for a hospital, aren't we going to end
- 4:00Speaker 1: up over engineering everything to the point of bankruptcy?
- 4:03Speaker 2: That is the exact friction point most people hit when
- 4:05Speaker 2: they first see these new maps.
- 4:07Speaker 1: I mean, a three thousand year storm implies an insanely
- 4:11Speaker 1: high wind speed. The steel required would just be astronomical.
- 4:14Speaker 2: Right, The speeds look terrifyingly high, but the economics actually
- 4:18Speaker 2: balance out because of how the load factors changed.
- 4:21Speaker 1: Okay, how so.
- 4:22Speaker 2: This ties into the shift toward limit state design. So
- 4:25Speaker 2: in the past, you took a lower fifty year wind speed,
- 4:28Speaker 2: calculated the force, and then multiplied that force by a safety.
- 4:31Speaker 1: Factor like a buffer.
- 4:33Speaker 2: Yeah, say a factor of one point six, just to
- 4:35Speaker 2: ensure the building wouldn't fail.
- 4:36Speaker 1: So you were adding an arbitrary buffer to cover the
- 4:39Speaker 1: unknown precisely.
- 4:41Speaker 2: But ASE seven sixteen pushed that safety buffer directly into
- 4:45Speaker 2: the map itself. A three thousand year map gives you
- 4:49Speaker 2: the ultimate limit state wind speed, the threshold right before
- 4:53Speaker 2: the structure completely fails. Oh, I see, because that speed
- 4:56Speaker 2: is already the absolute worst case scenario. The low factor
- 5:00Speaker 2: for wind, which you call W drops to one point zero.
- 5:03Speaker 1: For strength design, you just take the massive windload exactly
- 5:06Speaker 1: as it is. No multiplier, you.
- 5:07Speaker 2: Take it all one point Oh. Now, if an engineer
- 5:09Speaker 2: is still using allowable stress design, which is, you know,
- 5:12Speaker 2: an older methodology, they actually have to reduce that windload
- 5:15Speaker 2: to match the allowable stresses of the materials.
- 5:17Speaker 1: Okay, So what happens to the factor.
- 5:19Speaker 2: Then in that case, the factor drops from one point
- 5:21Speaker 2: zero down to point six.
- 5:23Speaker 1: So the math just got a lot more elegant it did.
- 5:25Speaker 1: The safety multiplier is built into the weather data itself.
- 5:29Speaker 1: And you know, beyond the math, this limit state approach
- 5:32Speaker 1: seems to provide a much more consistent probability of failure
- 5:36Speaker 1: across the entire country, regardless of geography exactly.
- 5:39Speaker 2: It equalizes the risk mathematically between hurricane prone coastlines and
- 5:43Speaker 2: the interior of the country.
- 5:44Speaker 1: Because a fifty year event in Miami is a major hurricane,
- 5:48Speaker 1: but in Omaha it's just a bad thunderstorm.
- 5:50Speaker 2: Right. So by pushing the interval out to three thousand
- 5:53Speaker 2: years for critical structures, you are targeting a uniform risk
- 5:57Speaker 2: of structural collapse everywhere.
- 6:00Speaker 1: Okay, so we figured out our baseline wind speed based
- 6:02Speaker 1: on risk tolerance. The next puzzle is translating that speed
- 6:05Speaker 1: into forces on actual physical materials, which introduces two acronyms
- 6:09Speaker 1: every engineering student must know.
- 6:11Speaker 2: Oh yeah, MWFRS and C and C the big ones,
- 6:15Speaker 2: the absolute bread and butter of wind design. MWFRS stands
- 6:18Speaker 2: for the main wind force resisting system, okay, and C
- 6:21Speaker 2: and C stands for components and cladding.
- 6:23Speaker 1: Let's define those conceptually. MWFRS feels like the bones and
- 6:28Speaker 1: muscles of the building, right, Yeah, that's a good way
- 6:30Speaker 1: to look at it. It handles the global stability. When
- 6:33Speaker 1: one hundred and twenty mile per hour wind slams into
- 6:36Speaker 1: a tall office tower, the MWFRS is the steel frame
- 6:40Speaker 1: or the concrete shear walls preventing the entire building from
- 6:43Speaker 1: tipping over as one giant unit.
- 6:45Speaker 2: Right it stops overall uplift, sliding, overturning, and then components
- 6:51Speaker 2: and cladding. The C and C is the building skin,
- 6:54Speaker 2: like the roof decking, the roof decking, the exterior wall panels, windows,
- 6:58Speaker 2: and crucially the individual fasteners and screws holding those panels
- 7:02Speaker 2: to the frame.
- 7:03Speaker 1: I always wondered about this. Actually, if I'm designing a
- 7:06Speaker 1: massive commercial metal warehouse and I calculate that the main
- 7:10Speaker 1: steel frame is mathematically strong enough to hold up, why
- 7:13Speaker 1: do I need an entirely separate, highly detailed set of
- 7:16Speaker 1: calculations just for a localized roof panel.
- 7:19Speaker 2: It is a really common assumption to think you don't
- 7:21Speaker 2: need to.
- 7:21Speaker 1: Right, like, isn't the metal skin automatically fine if the
- 7:24Speaker 1: skeleton holds, And.
- 7:25Speaker 2: That assumption is exactly how roofs get blown off. Yes,
- 7:28Speaker 2: oh yeah. The physical reality of wind is that it
- 7:31Speaker 2: doesn't hit a building like a flat, uniform wall of
- 7:34Speaker 2: force moving air behaves like a fluid, oh right, so
- 7:39Speaker 2: when it encounters a rigid obstacle, it has to aggressively
- 7:42Speaker 2: bend and accelerate to get around it. This creates intense
- 7:47Speaker 2: localized aerodynamic pressures, especially at geometric disruptions like corners, eaves,
- 7:52Speaker 2: and roof.
- 7:53Speaker 1: Ridges, because the air is detaching from the surface and
- 7:55Speaker 1: creating a localized vortex.
- 7:58Speaker 2: Think about water flowing around a jagged in a river.
- 8:01Speaker 2: You see those swirling violent eddies right behind the edges
- 8:03Speaker 2: of the rock.
- 8:04Speaker 1: Right, Yeah, totally.
- 8:05Speaker 2: Air does the exact same thing. A tight vortex spinning
- 8:08Speaker 2: at the corner of a roof creates extreme localized negative
- 8:11Speaker 2: pressure section. That suction might be double or triple the
- 8:15Speaker 2: average positive pressure pushing against the mainframe.
- 8:18Speaker 1: Wow, so the wind isn't just pushing the building over,
- 8:21Speaker 1: It's actively trying to vacuum the roof panels up into
- 8:23Speaker 1: the sky exactly.
- 8:25Speaker 2: And this is why C and C calculations isolate the
- 8:27Speaker 2: weakest link. A fastener re located right at the corner
- 8:30Speaker 2: of the roofs might experience catastrophic suction and snap.
- 8:32Speaker 1: And it rips a single panel off long before the
- 8:36Speaker 1: main structural frame even registers a heavy load right and.
- 8:40Speaker 2: C and sea pressures are tied directly to the effective
- 8:42Speaker 2: wind area. For a wall stud for example, it's the
- 8:45Speaker 2: span length multiplied by an effective width.
- 8:48Speaker 1: Which the guide says is not less than one third
- 8:50Speaker 1: the span.
- 8:51Speaker 2: Correct. The smaller the effective wind area, the higher the
- 8:54Speaker 2: aerodynamic pressure coefficient you have to use, because tiny localized
- 8:58Speaker 2: areas experience the sharpest spikes in vortec section.
- 9:01Speaker 1: Okay, so if you're evaluating that main skeleton, the MWFRS,
- 9:04Speaker 1: you have to choose a mathematical approach, and looking at
- 9:07Speaker 1: chapter twenty seven and twenty eight of ASCE seven sixteen,
- 9:11Speaker 1: engineers basically have to choose between two different analytical procedures.
- 9:15Speaker 2: Right, directional or envelope.
- 9:17Speaker 1: Let's break those down. The directional procedure is the universal one, right, Yes.
- 9:20Speaker 2: You can use it for a building of any height.
- 9:22Speaker 2: It relies on pressure coefficients or CP that are tied
- 9:25Speaker 2: to specific windward, leeward and sidewall directions.
- 9:28Speaker 1: Meaning you calculate the wind hitting the front wall, then
- 9:31Speaker 1: the suction on the back wall, then the sides. All
- 9:33Speaker 1: is separate directional events based on wind tunnel tests.
- 9:37Speaker 2: Exactly, you apply the force's surface by surface.
- 9:39Speaker 1: Then there is the envelope procedure. But this one has
- 9:43Speaker 1: strict geometric limitations. It is strictly for low rise buildings.
- 9:47Speaker 2: Yes, the mean roof height has to be sixty.
- 9:50Speaker 1: Feet or less, and the methodology here is totally different.
- 9:53Speaker 1: Instead of looking at specific wind directions, the envelope procedure
- 9:57Speaker 1: uses what they call pseudo pressure coefcion GCPF.
- 10:01Speaker 2: Right. These represent the maximum internal reactions like bending moments
- 10:07Speaker 2: and horizontal shears across the entire frame, regardless of which
- 10:11Speaker 2: specific direction the wind is blowing.
- 10:13Speaker 1: Here's where it gets really interesting. Let me try an
- 10:15Speaker 1: analogy here. The directional procedure is like taking specific sharp
- 10:19Speaker 1: photographs of a building from the north, south, east, and west.
- 10:23Speaker 1: You see exactly what is happening from each angle independently. Okay,
- 10:27Speaker 1: I like that, But the envelope procedure is like a
- 10:29Speaker 1: long exposure photograph where all the worst case wind directions
- 10:32Speaker 1: are blurred together into one maximum force envelope around the
- 10:36Speaker 1: entire building.
- 10:36Speaker 2: That's a perfect way to visualize it.
- 10:38Speaker 1: But here's my question. If I run both methods, the
- 10:41Speaker 1: directional and the envelope on the exact same fifty foot
- 10:45Speaker 1: commercial warehouse, do I get the exact same numbers at
- 10:49Speaker 1: the end of the day.
- 10:50Speaker 2: No, you absolutely do not, really, not at all. The
- 10:52Speaker 2: standard clearly notes the final loads do not match. You
- 10:56Speaker 2: cannot reconcile them.
- 10:57Speaker 1: That feels deeply unsettling. So the exact same building shouldn't
- 11:01Speaker 1: physics dictate a single correct answer.
- 11:03Speaker 2: Well, you have to remember that building codes are models
- 11:06Speaker 2: of reality. They aren't reality itself. These two procedures are
- 11:10Speaker 2: derived from fundamentally different wind tunnel data sets. They rely
- 11:14Speaker 2: on different behavioral models of the structure. The standard permits
- 11:17Speaker 2: either procedure for a low rise building, but engineers just
- 11:21Speaker 2: have to understand they're valuating different things.
- 11:23Speaker 1: Okay, so eventually, whichever philosophy you choose, every engineer has
- 11:27Speaker 1: to do the actual math to turn wind speed into
- 11:29Speaker 1: physical pounds of force. Let's look at the anatomy of
- 11:32Speaker 1: the velocity pressure.
- 11:33Speaker 2: Equation the core formula.
- 11:34Speaker 1: Yes, it's q equals zero points zero zero two five
- 11:37Speaker 1: six times c is times times k e times key
- 11:40Speaker 1: times v square.
- 11:41Speaker 2: That's the one.
- 11:42Speaker 1: You take the wind speed V square it and run
- 11:44Speaker 1: it through all these modifiers. KD is the directionality factor
- 11:49Speaker 1: usually point eight five, right, correct, But the factor I
- 11:51Speaker 1: really want to highlight, and this was a big deal.
- 11:53Speaker 1: In seven sixteen is K the ground elevation factor.
- 11:57Speaker 2: Oh, this was a highly anticipated update. It addresses the
- 12:00Speaker 2: reality that air density changes with higher.
- 12:03Speaker 1: Elevations because if you are designing a building in Denver, Colorado,
- 12:08Speaker 1: at five thousand feet, the air is physically thinner than
- 12:11Speaker 1: in Miami.
- 12:12Speaker 2: Right, Thinner air means less mass. Less mass means less
- 12:15Speaker 2: kinetic energy hitting the building, even if the wind speed
- 12:18Speaker 2: is identical. So this elevation factor allows for reduced wind
- 12:22Speaker 2: pressures in mountainous regions.
- 12:24Speaker 1: It's such a practical update, but calculating the pressure on
- 12:27Speaker 1: the outside of the building is only half the battle.
- 12:29Speaker 1: We also have to deal with the wind potentially getting
- 12:31Speaker 1: inside the building.
- 12:32Speaker 2: Internal pressure. Yes, GCPI right.
- 12:35Speaker 1: How does wind getting inside change things?
- 12:38Speaker 2: It changes everything. Internal pressure can be the final nail
- 12:41Speaker 2: in the coffin. Imagine a severe storm is outside, creating
- 12:44Speaker 2: massive section on your roof, trying to pull it upward.
- 12:47Speaker 2: Suddenly a large bay door fails or debris shatters a
- 12:51Speaker 2: massive window. The wind rushes in.
- 12:53Speaker 1: The wind rushes in, and it instantly pressurizes the inside
- 12:56Speaker 1: of the building like a balloon.
- 12:57Speaker 2: Exactly. So now you have the wind outside sucking the
- 13:01Speaker 2: roof up, and the wind inside violently pushing the roof up,
- 13:05Speaker 2: it just blows the roof clean off.
- 13:06Speaker 1: Wow, a double whammy, which.
- 13:08Speaker 2: Is why for a completely enclosed building the coefficient is
- 13:11Speaker 2: plus or minus point one eight.
- 13:13Speaker 1: Plus or minus, meaning you have to design for both
- 13:16Speaker 1: a ballooning effect and a vacuum effect.
- 13:18Speaker 2: Yes, because even fully enclosed buildings leak air through tiny gaps,
- 13:23Speaker 2: you must check both conditions. And if we connect this
- 13:26Speaker 2: to the bigger picture, this single velocity pressure formula we
- 13:30Speaker 2: just walked through. It synthesizes geography, topography, altitude, and meteorology
- 13:35Speaker 2: into one workable engineering number.
- 13:38Speaker 1: It really is amazing when you step back and look
- 13:39Speaker 1: at it. But we've been assuming these buildings are rigid blocks.
- 13:42Speaker 1: What happens when the math hits the real oddly.
- 13:45Speaker 2: Shaped world right the edge cases.
- 13:47Speaker 1: Like a massive solid billboard is sitting on top of
- 13:49Speaker 1: sixty foot flexible steel poles.
- 13:52Speaker 2: That is a classic example that behaves like a giant
- 13:54Speaker 2: tuning fork. It is classified as flexible, not rigid.
- 13:57Speaker 1: The Colburn and Stafford guide notes that if its fundamental
- 14:01Speaker 1: natural frequency is less than one hurt, say some point
- 14:04Speaker 1: seven hurts. You can't just use the standard point eighty
- 14:07Speaker 1: five gust effect factor.
- 14:08Speaker 2: No, you absolutely cannot. Under one hertz means it sways
- 14:12Speaker 2: slowly enough that the natural buffeting of the wind can
- 14:15Speaker 2: actually catch it and create a dynamic resonance response.
- 14:18Speaker 1: Right, the wind pushes it rhythmically.
- 14:20Speaker 2: Exactly, you must calculate a dynamic resonance response factor GRIFF,
- 14:24Speaker 2: which might jump up to something like one point one four.
- 14:26Speaker 1: That's a massive increase. What about unusually shaped buildings like
- 14:30Speaker 1: a dome.
- 14:31Speaker 2: ASSE seven to sixteen doesn't perfectly cover every shape, but
- 14:35Speaker 2: the guide demonstrates using force coefficients derived from round tanks
- 14:38Speaker 2: and chimneys.
- 14:39Speaker 1: Which vary based on height todiameter ratio.
- 14:41Speaker 2: You can get a surface roughness.
- 14:42Speaker 1: Okay, before we wrap up, you mentioned a huge red
- 14:45Speaker 1: flag in the guide regarding chapter fourteen.
- 14:46Speaker 2: Yes, this is a crucial warning. Never ever mix coefficients
- 14:51Speaker 2: from older codes like acc IS seven eighty eight with
- 14:54Speaker 2: ACE seven sixteen.
- 14:56Speaker 1: Because older codes use fastest mile wind speeds, where where
- 15:00Speaker 1: as seven point sixteen uses three second gust speeds.
- 15:03Speaker 2: Right, exactly, fast mile is an average over a longer duration.
- 15:07Speaker 2: Three second gusts is an instantaneous peak velocity. Interchanging them
- 15:11Speaker 2: will lead to catastrophic calculation errors.
- 15:14Speaker 1: That is a sobering reminder. All right, listener, it's time
- 15:17Speaker 1: to see if you were tracking with us. Here is
- 15:19Speaker 1: your review exercise to reinforce what you've learned today.
- 15:22Speaker 2: Let's see how well you absorbed the rules.
- 15:24Speaker 1: Imagine you are designing a one story commercial warehouse with
- 15:27Speaker 1: a mean roof height of forty five feet. Based on
- 15:30Speaker 1: what we just discussed, are you legally permitted by ASEE
- 15:34Speaker 1: seven sixteen to use the envelope procedure for the main
- 15:37Speaker 1: wind force resisting system?
- 15:39Speaker 2: Think about the height limits.
- 15:40Speaker 1: And second, if this building is completely enclosed, what internal
- 15:43Speaker 1: pressure coefficients GCPI must you factor into your final design
- 15:47Speaker 1: pressure equation?
- 15:48Speaker 2: Remember the ballooning and vacuum effects.
- 15:50Speaker 1: The answers, yes, you are permitted because the building is
- 15:53Speaker 1: under sixty feet and you must use plus or minus
- 15:55Speaker 1: point one eight for an enclosed building.
- 15:58Speaker 2: Spun on, and I want to leave you, you the
- 16:00Speaker 2: listener with a final thought to ponder. We've seen how
- 16:04Speaker 2: ASEE seven sixteen shifted to three thousand year mean recurrence
- 16:07Speaker 2: intervals to better capture limit state probabilities. Right using historical
- 16:12Speaker 2: weather data, but with shifting global climate patterns and the
- 16:15Speaker 2: increasing intensity of severe weather events. This raises an important question,
- 16:19Speaker 2: how long will those historical three thousand year wind models
- 16:22Speaker 2: accurately reflect our future atmospheric reality. Will the engineering community
- 16:27Speaker 2: soon have to redefine the very baseline of what a
- 16:30Speaker 2: maximum wind speed.
- 16:31Speaker 1: Is that is heavy? So what does this all mean?
- 16:34Speaker 1: It means Mastering these provisions isn't just about passing a
- 16:36Speaker 1: plan check. It's about ensuring the built environment stands strong
- 16:39Speaker 1: against whatever the sky throws at it. Thanks for taking
- 16:42Speaker 1: this deep dive with us.