Latest / Civil Engineering Made Simple / Steel Design Guide: Serviceability Design Considerations for Steel Buildings
Transcript
- 0:00Speaker 1: Welcome back to the deep dive. Today, we're going to
- 0:03Speaker 1: jump into what I think is the secret weapon of
- 0:07Speaker 1: really high quality building design serviceability. I mean, for a
- 0:13Speaker 1: lot of students and young engineers, all the focus is
- 0:15Speaker 1: on strength, making sure the building doesn't.
- 0:17Speaker 2: Fall down right, which is obviously critical. But what happens
- 0:21Speaker 2: after its standing that's where we pivot exactly. Today we
- 0:24Speaker 2: are diving into the AISC Design Guide three Serviceability Design
- 0:29Speaker 2: Considerations for steel buildings. And if strength is about safety,
- 0:33Speaker 2: serviceability is all about performance.
- 0:35Speaker 1: So does it work? Is it comfortable? Does it look good?
- 0:38Speaker 2: That's it. It's about fulfilling its function, maintaining its appearance,
- 0:41Speaker 2: and you know, ensuring occupant comfort under a just normal,
- 0:44Speaker 2: everyday use.
- 0:46Speaker 1: It really feels like the difference between a building that's
- 0:48Speaker 1: just compliant and one that's actually successful.
- 0:51Speaker 2: Absolutely, if you exceed a strength limit, that's a catastrophe,
- 0:54Speaker 2: but if you exceed a serviceability limit, well you get
- 0:57Speaker 2: expensive fixes, endless tenant complaints, and your reputation takes a hit.
- 1:01Speaker 1: We're talking about things like cracks in the dry wall,
- 1:04Speaker 1: floors that feel bouncy or just weird movements that make people.
- 1:07Speaker 2: Uncomfortable, and that's the fundamental distinction. Strength limits are technical,
- 1:12Speaker 2: they're in the code and you must meet them. Serviceability
- 1:15Speaker 2: limits they're often not technical, more subjective kind of. They're
- 1:19Speaker 2: based on human perception, on expectations. It's really more of
- 1:23Speaker 2: a contractual matter. ACE seven tells us to provide adequate stiffness,
- 1:28Speaker 2: but the actual targets often come from a conversation between
- 1:32Speaker 2: the owner, the architect, and the engineer.
- 1:35Speaker 1: Okay, so that sets our roadmap for today. We're going
- 1:37Speaker 1: to distill this guide down into four key areas. First,
- 1:40Speaker 1: keeping the water out with roofing, then preventing damage to
- 1:43Speaker 1: walls and cladding, after that, making sure floors are flat
- 1:46Speaker 1: and feel solid, and finally controlling that jiggle vibration.
- 1:50Speaker 2: Sounds like a plan, All right, Let's.
- 1:52Speaker 1: Start at the very foundation, the limits and the loads.
- 1:55Speaker 1: You said the goal is performance under normal conditions. So
- 1:57Speaker 1: I'm guessing we don't use the same worst case scenario
- 2:00Speaker 1: loads we use for strength design.
- 2:02Speaker 2: You've nailed it. That is the huge conceptual leap for
- 2:06Speaker 2: safety and stability. Yeah, you use factored maximum once in
- 2:10Speaker 2: a lifetime loads, but for serviceability you want realistic loads.
- 2:14Speaker 2: The building sees ninety nine percent of the time.
- 2:17Speaker 1: Okay, so let's talk wind. We need to check for drift,
- 2:20Speaker 1: but we're worried about the building moving during what a
- 2:23Speaker 1: strong storm? Not a hurricane exactly.
- 2:25Speaker 2: We're checking for the kind of wind that happens more often.
- 2:29Speaker 2: The guide suggests using the ten year recurrence interval wind And.
- 2:33Speaker 1: Do you need a whole separate climate study for that not?
- 2:36Speaker 2: Usually No, The guide gives a pretty good rule of thumb.
- 2:38Speaker 2: You can approximate it as seventy five percent of the
- 2:41Speaker 2: fifty year strength design wind pressure. It's a common, easy
- 2:44Speaker 2: to use.
- 2:45Speaker 1: Shortcut that makes a lot of sense. You're checking to
- 2:47Speaker 1: make sure the windows don't crack during a common storm.
- 2:49Speaker 2: Okay, so what about vertical loads for beams and joists.
- 2:52Speaker 1: For short term effects like immediate sag, the combinations are
- 2:56Speaker 1: pretty straightforward. You check dead load plus the full live load,
- 2:59Speaker 1: so D plus L or deadload plus half the snowload.
- 3:04Speaker 1: And what about long term I'm thinking about things like
- 3:07Speaker 1: concrete creep over many years.
- 3:09Speaker 2: Precisely, for those long term effects like creep or even
- 3:13Speaker 2: foundation settlement, you assume a much smaller sustained live load.
- 3:18Speaker 2: The guide suggests deadload plus half the live load, or
- 3:21Speaker 2: D plus zero point five to all.
- 3:23Speaker 1: Because the full design live load isn't just sitting there
- 3:26Speaker 1: for fifty years straight.
- 3:27Speaker 2: Right people furniture, it all moves. It recognizes that reality.
- 3:32Speaker 1: What if you need to combine them, like for drift
- 3:35Speaker 1: check with people in the building.
- 3:36Speaker 2: For a lateral drift check, a common combination is dead
- 3:39Speaker 2: load plus half the live load plus seven tenths of
- 3:42Speaker 2: that windload we just talked about.
- 3:43Speaker 1: So D plus point five to low plus point seven.
- 3:46Speaker 1: W Yep.
- 3:47Speaker 2: These combinations just make sure our checks reflect what's likely
- 3:50Speaker 2: to happen at the same time without being way too
- 3:52Speaker 2: conservative and expensive.
- 3:54Speaker 1: Okay, let's unpack one of the trickiest issues, one where
- 3:57Speaker 1: serviceability can bleed right into a strength problem if you
- 4:00Speaker 1: ignore it. I'm talking about roofing and.
- 4:01Speaker 2: Ponding, ah, ponding. It's so interesting because it's a structural
- 4:05Speaker 2: instability problem that disguises itself as a serviceability check. It's
- 4:10Speaker 2: a feedback loop.
- 4:11Speaker 1: Isn't it. It is a classic dangerous feedback loop. The
- 4:14Speaker 1: weight of some rain water makes the roof deflect a little.
- 4:18Speaker 1: That little depression allows more water to accumulate, which adds
- 4:21Speaker 1: more weight, which causes more deflection on an on ego
- 4:24Speaker 1: until potentially failure. It's an iterative process.
- 4:28Speaker 2: So to fight this, the AISC spec has those really
- 4:33Speaker 2: complex stability equations in section K two, the ones with
- 4:37Speaker 2: C sop and C subs right.
- 4:39Speaker 1: Those equations guarantee stability against this iterative collapse. But, and
- 4:44Speaker 1: this is a key takeaway from the design guide meeting
- 4:46Speaker 1: those criteria can sometimes force you into a design with
- 4:49Speaker 1: really heavy, overly stiff beams.
- 4:51Speaker 2: So an unnecessarily expensive root it can be. Yeah, so
- 4:54Speaker 2: it's the alternative if those equations give you a design
- 4:57Speaker 2: that's just too bulky.
- 4:58Speaker 1: Well engineers often an alternative stress based check. You basically
- 5:02Speaker 1: calculate the final deflection from all that accumulated water and
- 5:06Speaker 1: just make sure the final binning stress in the beam
- 5:08Speaker 1: doesn't exceed its yield stress. Ricky.
- 5:10Speaker 2: But there's a catch right there is you have to
- 5:13Speaker 2: subtract the stress that's already in the beam when the
- 5:16Speaker 2: ponding starts. The guide calls it f subbo the initial stress.
- 5:20Speaker 1: Okay, and getting that initial stress number right is critical.
- 5:23Speaker 2: What goes into that well F subbo is the stress
- 5:26Speaker 2: from loads that are already there before the big rainstorm hits.
- 5:30Speaker 2: So that's the dead load of the steel the deck,
- 5:32Speaker 2: and then you have to make a judgment, call the
- 5:34Speaker 2: judgment coll Yeah, you have to decide how much snow
- 5:37Speaker 2: or trapped water might already be on the roof. The
- 5:39Speaker 2: Steel Joist Institute, for example, suggests using fifty percent of
- 5:43Speaker 2: the design live load if you're in a snow region.
- 5:46Speaker 1: So the engineer has to consciously decide what the starting
- 5:50Speaker 1: conditions are precisely.
- 5:52Speaker 2: And if you assume a really high initial stress, you
- 5:55Speaker 2: have less capacity left to handle the ponding water. It
- 5:58Speaker 2: really requires careful engineering judgment.
- 6:01Speaker 1: Now, beyond just stability, there's the roofing material itself. You
- 6:04Speaker 1: have to make sure the structure isn't moving so much
- 6:06Speaker 1: that it breaks the waterproof.
- 6:08Speaker 2: Membrane right, which brings us to drainage and deflection limits. Functionally,
- 6:13Speaker 2: ASE seven says you need a minimum slope of a
- 6:16Speaker 2: quarter inch per foot for positive drainage. Structurally, SJI limits
- 6:20Speaker 2: the live load deflection for joists to the span divided
- 6:23Speaker 2: by two hundred and forty l over two hundred and
- 6:26Speaker 2: forty And.
- 6:27Speaker 1: What about metal roofs I hear they can be a
- 6:29Speaker 1: bit sensitive.
- 6:29Speaker 2: They can be for something like a standing seam roof.
- 6:32Speaker 2: The check is usually just to make sure you maintain
- 6:34Speaker 2: that positive drainage under a realistic load like dead load
- 6:37Speaker 2: plus half the snow load. The limits can sometimes be
- 6:40Speaker 2: a bit looser, maybe l over one fifty for pearlins
- 6:43Speaker 2: under snow okay.
- 6:44Speaker 1: So once we've kept the weather out, we have to
- 6:45Speaker 1: worry about the building moving side to side, and that
- 6:48Speaker 1: brings us to the skim of the building, the cladding.
- 6:51Speaker 1: This is where engineering and architecture can really clash.
- 6:54Speaker 2: That tension is very real. The key design strategy here
- 6:57Speaker 2: has to be what the guide calls divorcement.
- 7:00Speaker 1: You have to keep them separate.
- 7:01Speaker 2: You have to the connections between the cladding, whether it's
- 7:04Speaker 2: glass or brick or panels, and the steel frame need
- 7:08Speaker 2: to be designed to be statically determinate. If you don't,
- 7:11Speaker 2: the stiff cladding tries to act with the frame, and
- 7:14Speaker 2: that almost guarantees it's going to crack or break.
- 7:16Speaker 1: And the big check here is inner story drift. Using
- 7:20Speaker 1: those ten year windloads, I assume the limits change depending
- 7:23Speaker 1: on what the wall is made of.
- 7:24Speaker 2: Completely the material sensitivity to movement dictates everything. For something
- 7:30Speaker 2: robust like pre cast concrete panels, you might get away
- 7:34Speaker 2: with a limit like h over one hundred.
- 7:36Speaker 1: The story hike divided by one.
- 7:37Speaker 2: Hundred, right, But if you switch to say standard reinforced masonry,
- 7:42Speaker 2: which hates tension, you have to tighten that up significantly,
- 7:45Speaker 2: usually to h over two hundred, just to control the
- 7:48Speaker 2: crack widths.
- 7:49Speaker 1: And what about something like a big fancy glass curtain wall.
- 7:52Speaker 1: I know those have the toughest limits.
- 7:53Speaker 2: They do, and this is where the design cost can
- 7:55Speaker 2: really go up. A common target for their relative movement
- 7:58Speaker 2: between stories for a curtain wall is h over five
- 8:01Speaker 2: hundred h.
- 8:01Speaker 1: Over five hundred, so for a twelve foot story, that's
- 8:04Speaker 1: less than a third of an inch of movement exactly.
- 8:07Speaker 2: And it's not even just about the glass breaking. It's
- 8:09Speaker 2: about preserving the seals and gaskets between the panels to
- 8:13Speaker 2: stop air and water from getting in.
- 8:15Speaker 1: And it's not just the mainframe, is it. You had
- 8:17Speaker 1: to think about the little pieces, the girts and wind
- 8:19Speaker 1: columns that actually hold the cladding.
- 8:21Speaker 2: Oh. Absolutely, those localized deflections are just as important. For
- 8:25Speaker 2: members holding metal panels, the limit is typically l over
- 8:28Speaker 2: one hundred and twenty. If they're holding masonry, it gets
- 8:31Speaker 2: much stricter.
- 8:32Speaker 1: Let me guess l over two forty ll.
- 8:34Speaker 2: Over two forty Yeah, with an absolute maximum of one
- 8:37Speaker 2: and a half inches. But the absolute king of strictness
- 8:40Speaker 2: in this category is the masonry LENTTL.
- 8:42Speaker 1: The beam over a window or door.
- 8:45Speaker 2: That's the one. The limit for a lntal supporting a
- 8:48Speaker 2: brick wall is l over six hundred, or an absolute
- 8:51Speaker 2: max of point three inches, and that point three inch
- 8:54Speaker 2: maximum often controls because masonry just cannot bridge a gap,
- 8:58Speaker 2: it will crack.
- 8:58Speaker 1: Wow. Also have to think about vertical movement right, especially
- 9:02Speaker 1: on spandrel beams around the edge of the floor.
- 9:04Speaker 2: Timing is everything there. You have to control the deflection
- 9:06Speaker 2: that happens before the cladding goes on, and then what
- 9:08Speaker 2: happens after. The dead Load deflection before the cladding is
- 9:12Speaker 2: installed is often limited to just three eighths of an inch.
- 9:15Speaker 2: Then any additional dead load deflection after it's installed is
- 9:19Speaker 2: limited to something like l over four to.
- 9:21Speaker 1: Eighty so the frame doesn't sag and pull the new
- 9:24Speaker 1: windows down with it.
- 9:25Speaker 2: You got it.
- 9:25Speaker 1: Okay, let's move inside the building. Floors, flatness and partitions.
- 9:30Speaker 1: We all know the standard live load deflection limit for
- 9:33Speaker 1: a floor is l over three sixty.
- 9:35Speaker 2: That's the classic starting point, but it gets overruled all
- 9:38Speaker 2: the time. Why what by the finishes Think about a
- 9:41Speaker 2: dry wall or plaster ceiling hanging from the floor above.
- 9:45Speaker 2: Those systems are brittle. They can often only tolerate a
- 9:48Speaker 2: quarter inch maybe a half inch of total movement before
- 9:51Speaker 2: they start to crack or jam up.
- 9:52Speaker 1: So that absolute number a quarter inch could be way
- 9:56Speaker 1: stricter than l over three to sixty on a shorter beam.
- 9:58Speaker 2: Often is it's a clou that's a conflict between the
- 10:01Speaker 2: structural standard and the architectural reality, and that's why serviceability
- 10:05Speaker 2: is all about collaboration. If the architect wants a perfectly
- 10:08Speaker 2: smooth plaster ceiling, the engineer has to provide a much
- 10:11Speaker 2: stiffer beam.
- 10:12Speaker 1: Now, engineers try to solve this with camber right bending
- 10:16Speaker 1: the beam upwards to counteract the deadload.
- 10:19Speaker 2: They do, but cambering is an imperfect art. The AISC
- 10:23Speaker 2: Code of Standard Practice allows a tolerance of minus zero
- 10:26Speaker 2: plus a half inch for most beams, so it's always
- 10:29Speaker 2: been either correctly or a little too much. It inherently
- 10:32Speaker 2: biases the system toward being over cambered, and if a
- 10:35Speaker 2: beam is a little too high in the middle, the
- 10:37Speaker 2: concrete contractor who just wants a flat floor might pour
- 10:41Speaker 2: extra concrete there to level it out.
- 10:43Speaker 1: So the solution to control deflection accidentally adds more deadload.
- 10:47Speaker 2: It's a compounding risk. That's why there's another recommendation limit
- 10:51Speaker 2: the deflection from just the wet concrete and steel to
- 10:54Speaker 2: l over three sixty or one inch max. It helps
- 10:57Speaker 2: control that concrete ponding.
- 10:59Speaker 1: And what about shortening in tall buildings.
- 11:01Speaker 2: Yeah, in high rises you have to account for it.
- 11:04Speaker 2: The columns actually get slightly shorter under the immense weight.
- 11:07Speaker 2: During erection. You have to survey and use shims to
- 11:10Speaker 2: make sure the floor elevations stay where they're supposed to
- 11:12Speaker 2: be as the tower goes up.
- 11:13Speaker 1: Okay, Now for the part that people feel the most,
- 11:16Speaker 1: controlling the jiggle vibration.
- 11:20Speaker 2: For tall buildings, the metric we use is acceleration. You
- 11:23Speaker 2: don't really feel how far a building moves. You feel
- 11:26Speaker 2: it's speeding up and slowing down.
- 11:28Speaker 1: And what are the targets that engineers aim for.
- 11:30Speaker 2: They're not official code, but they are widely accepted. For
- 11:34Speaker 2: a commercial office building, the target is a peak acceleration
- 11:38Speaker 2: of about twenty one milligies. For a residential building, it's
- 11:42Speaker 2: much stricter fifteen milagies, and.
- 11:44Speaker 1: That's stricter just because people are more sensitive at home.
- 11:47Speaker 2: Exactly, you're there for longer, you're often sitting or lying down,
- 11:51Speaker 2: and you just have a lower tolerance for feeling the
- 11:53Speaker 2: building move under you.
- 11:55Speaker 1: Perception is a funny thing, it is.
- 11:57Speaker 2: And it's affected by frequency, by whether you're sitting or stand,
- 12:00Speaker 2: and especially by visual cues. We are also way more
- 12:03Speaker 2: sensitive to twisting motions portional acceleration than straight back and
- 12:08Speaker 2: forth movement.
- 12:09Speaker 1: So if we go from the whole building moving to
- 12:11Speaker 1: specific equipment, the limits just get astronomical. I don't think
- 12:15Speaker 1: of attraction elevators.
- 12:16Speaker 2: This is the gold standard for stiffness, and it has
- 12:19Speaker 2: nothing to do with human comfort. It's all about the machine.
- 12:22Speaker 1: What's the number.
- 12:23Speaker 2: Antiasme A seventeen point one has a rule the deflection
- 12:26Speaker 2: of the machine and sheave beams under static unfactored loads
- 12:30Speaker 2: cannot exceed l over sixteen sixty six.
- 12:33Speaker 1: L over sixteen sixty six that is just an insane
- 12:36Speaker 1: number compared to the l over three sixty we use
- 12:38Speaker 1: for a floor.
- 12:39Speaker 2: Why so stiff It's all about alignment. Traction elevators work
- 12:43Speaker 2: with incredibly precise alignment of cables sheaves and counterweights. If
- 12:48Speaker 2: those support beams deflect even a tiny bit too much,
- 12:51Speaker 2: a rope could slip, a safety device could trip, and
- 12:54Speaker 2: the elevator is out of service. It's a pure performance.
- 12:56Speaker 1: Limit, and the elevator shaft itself has to be straight too.
- 12:59Speaker 1: I assume it does.
- 13:00Speaker 2: A drift limit of h over five hundred is often recommended,
- 13:02Speaker 2: just to keep the rails aligned.
- 13:04Speaker 1: Okay. Last category, cranes in industrial.
- 13:07Speaker 2: Buildings YEP and crane limits are dictated by the Crane
- 13:10Speaker 2: Manufacturers Association the CMAA for vertical deflection, the limits depend
- 13:15Speaker 2: on usage. For a light duty crane, it might be
- 13:17Speaker 2: l over six hundred. For a heavy continuous use steel
- 13:21Speaker 2: mill crane that tightens to l over one thousand.
- 13:23Speaker 1: And for a crane with an operator in a cab,
- 13:25Speaker 1: I bet there's a drift limit for their comfort. Just
- 13:28Speaker 1: like the residential tower.
- 13:29Speaker 2: That's the perfect comparison. The lateral drift at the runway
- 13:32Speaker 2: is limited to h over two hundred and forty or
- 13:35Speaker 2: two inches max. You have to make sure the operator
- 13:37Speaker 2: feels safe up there.
- 13:39Speaker 1: So we've covered the whole building. Roofs, walls, floors, vibration machinery.
- 13:44Speaker 1: What's the big takeaway for a practicing engineer.
- 13:47Speaker 2: I think the takeaway is that serviceability is the ultimate
- 13:50Speaker 2: act of collaboration and judgment. The codified limits are few
- 13:54Speaker 2: and far between. Success really hinges on the engineer proactively
- 13:58Speaker 2: coordinating with everyone, the architect, the equipment supplier, the owner
- 14:02Speaker 2: to understand what performance actually means for every single component.
- 14:06Speaker 1: So it's not a side check.
- 14:07Speaker 2: It's not a side check. It's the metric of a
- 14:09Speaker 2: high quality building. It's what saves the owner from a
- 14:12Speaker 2: death by a thousand cuts from post construction problems.
- 14:15Speaker 1: That brings us to our final thought, fee to chew on,
- 14:18Speaker 1: we just heard that the insane l over sixteen to
- 14:21Speaker 1: sixty six deflection limit for elevator beams is based on
- 14:24Speaker 1: unvectored static loads. Meanwhile, most other serviceability checks use reduced
- 14:29Speaker 1: loads like half the live load. So given that vast
- 14:33Speaker 1: numerical difference, why do you think the elevator beam requirement
- 14:36Speaker 1: is almost universally seen as the single most demanding serviceability
- 14:39Speaker 1: limit in all of steel design?
- 14:41Speaker 2: A fantastic question to wrap it up. Thanks for diving
- 14:43Speaker 2: into the AISC Design Guide three with us
- 14:46Speaker 1: Today and we'll catch you on the next deep dive